Determination of hydrazine in drinking water: Development and multivariate optimization of a rapid and simple solid phase microextraction-gas chromatography-triple quadrupole mass spectrometry protocol

被引:38
作者
Gionfriddo, Emanuela [1 ]
Naccarato, Attilio [1 ]
Sindona, Giovanni [1 ]
Tagarelli, Antonio [1 ]
机构
[1] Univ Calabria, Dipartimento Chim & Tecnol Chim, I-87030 Arcavacata Di Rende, CS, Italy
关键词
Hydrazine; Drinking water; Solid phase microextraction; Gas chromatography; Chloroformates; Experimental design; INJECTION CHEMILUMINESCENCE DETERMINATION; CHLOROFORMATE-MEDIATED DERIVATIZATION; FLOW-INJECTION; SPECTROPHOTOMETRIC DETERMINATION; SENSITIVE DETERMINATION; AQUEOUS MATRICES; TRACE HYDRAZINE; ASSAY; 1,2-DIMETHYLHYDRAZINE; DERIVATIVES;
D O I
10.1016/j.aca.2014.05.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, the capabilities of solid phase microextraction were exploited in a fully optimized SPME-GC-QqQ-MS analytical approach for hydrazine assay. A rapid and easy method was obtained by a simple derivatization reaction with propyl chloroformate and pyridine carried out directly in water samples, followed by automated SPME analysis in the same vial without further sample handling. The affinity of the different derivatized compounds obtained towards five commercially available SPME coatings was evaluated, in order to achieve the best extraction efficiency. GC analyses were carried out using a GC-QqQ-MS instrument in selected reaction monitoring (SRM) acquisition mode which has allowed the achievement of high specificity by selecting appropriate precursor-product ion couples improving the capability in analyte identification. The multivariate approach of experimental design was crucial in order to optimize derivatization reaction, SPME process and tandem mass spectrometry parameters. Accuracy of the proposed protocol, tested at 60, 200 and 800 ng L-1, provided satisfactory values (114.2%, 83.6% and 98.6%, respectively), whereas precision (RSD%) at the same concentration levels were of 10.9%, 7.9% and 7.7% respectively. Limit of detection and quantification of 4.4 and 8.3 ng L-1 were obtained. The reliable application of the proposed protocol to real drinking water samples confirmed its capability to be used as analytical tool for routine analyses. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 45
页数:9
相关论文
共 46 条
[1]   Multistage mass spectrometry in quality, safety and origin of foods [J].
Aiello, Donatella ;
De Luca, Damiano ;
Gionfriddo, Emanuela ;
Naccarato, Attilio ;
Napoli, Anna ;
Romano, Elvira ;
Russo, Anna ;
Sindona, Giovanni ;
Tagarelli, Antonio .
EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2011, 17 (01) :1-31
[2]   Improved procedure for n-hexyl chloroformate-mediated derivatization of highly hydrophilic substances directly in water:hydroxyaminic compounds [J].
Angelino, S ;
Maurino, V ;
Minero, C ;
Pelizzetti, E ;
Vincenti, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (02) :307-316
[3]  
[Anonymous], 2000, KIRK OTHMER ENCY CHE
[4]  
[Anonymous], INT RISK INF SYST
[5]  
Ashford R.D., 1994, ASHFORDS DICT IND CH
[6]  
Budavari S., 1996, The Merck Index: An Encyclopedia of Chemicals, Drugs, and Biologicals, V12th
[7]   A solid-phase microextraction-gas chromatographic approach combined with triple quadrupole mass spectrometry for the assay of carbamate pesticides in water samples [J].
Cavaliere, Brunella ;
Monteleone, Marcello ;
Naccarato, Attilio ;
Sindona, Giovanni ;
Tagarelli, Antonio .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1257 :149-157
[8]   Sarcosine as a marker in prostate cancer progression: a rapid and simple method for its quantification in human urine by solid-phase microextraction-gas chromatography-triple quadrupole mass spectrometry [J].
Cavaliere, Brunella ;
Macchione, Barbara ;
Monteleone, Marcello ;
Naccarato, Attilio ;
Sindona, Giovanni ;
Tagarelli, Antonio .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) :2903-2912
[9]   Sensitive and selective fluorescence determination of trace hydrazine in aqueous solution utilizing 5-chlorosalicylaldehyde [J].
Chen, Xiaotong ;
Xiang, Yu ;
Li, Zifan ;
Tong, Aijun .
ANALYTICA CHIMICA ACTA, 2008, 625 (01) :41-46
[10]  
Cudjoe E, 2012, BIOANALYSIS, V4, P2605, DOI [10.4155/bio.12.250, 10.4155/BIO.12.250]