Rapid Ex Vivo Imaging of PAIII Prostate to Bone Tumor with SWIFT-MRI

被引:11
作者
Luhach, Ihor [1 ,2 ,3 ]
Idiyatullin, Djaudat [4 ]
Lynch, Conor C. [5 ]
Corum, Curt [4 ]
Martinez, Gary V. [1 ,2 ]
Garwood, Michael [4 ]
Gillies, Robert J. [1 ,2 ]
机构
[1] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Dept Canc Imaging, Tampa, FL 33612 USA
[2] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Dept Metab, Tampa, FL 33612 USA
[3] Univ S Florida, Dept Math & Stat, Tampa, FL 33612 USA
[4] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN USA
[5] Univ S Florida, Coll Med, H Lee Moffitt Canc Ctr & Res Inst, Dept Tumor Biol, Tampa, FL 33612 USA
关键词
SWIFT; MRI; cancer; imaging; bone; CT; ULTRASHORT ECHO-TIME; CORTICAL BONE; T-2; PULSES; EXCITATION;
D O I
10.1002/mrm.24979
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The limiting factor for MRI of skeletal/mineralized tissue is fast transverse relaxation. A recent advancement in MRI technology, SWIFT (Sweep Imaging with Fourier Transform), is emerging as a new approach to overcome this difficulty. Among other techniques like UTE, ZTE, and WASPI, the application of SWIFT technology has the strong potential to impact preclinical and clinical imaging, particularly in the context of primary or metastatic bone cancers because it has the added advantage of imaging water in mineralized tissues of bone allowing MRI images to be obtained of tissues previously visible only with modalities such as computed tomography (CT). The goal of the current study is to examine the feasibility of SWIFT for the assessment of the prostate cancer induced changes in bone formation (osteogenesis) and destruction (osteolysis) in ex vivo specimens. Methods: A luciferase expressing prostate cancer cell line (PAIII) or saline control was inoculated directly into the tibia of 6-week-old immunocompromised male mice. Tumor growth was assessed weekly for 3 weeks before euthanasia and dissection of the tumor bearing and sham tibias. The ex vivo mouse tibia specimens were imaged with a 9.4 Tesla (T) and 7T MRI systems. SWIFT images are compared with traditional gradient-echo and spin-echo MRI images as well as CT and histological sections. Results: SWIFT images with nominal resolution of 78 mm are obtained with the tumor and different bone structures identified. Prostate cancer induced changes in the bone microstructure are visible in SWIFT images, which is supported by spin-echo, high resolution CT and histological analysis. Conclusion: SWIFT MRI is capable of high-quality high-resolution ex vivo imaging of bone tumor and surrounding bone and soft tissues. Furthermore, SWIFT MRI shows promise for in vivo bone tumor imaging, with the added benefits of nonexposure to ionizing radiation, quietness, and speed. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:858 / 863
页数:6
相关论文
共 31 条
  • [1] Ultra-short echo-time MRI detects changes in bone mineralization and water content in OVX rat bone in response to alendronate treatment
    Anumula, S.
    Wehrli, S. L.
    Magland, J.
    Wright, A. C.
    Wehrli, F. W.
    [J]. BONE, 2010, 46 (05) : 1391 - 1399
  • [2] Characterization and Correction of System Delays and Eddy Currents for MR Imaging with Ultrashort Echo-Time and Time-Varying Gradients
    Atkinson, Ian C.
    Lu, Aiming
    Thulborn, Keith R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 532 - 537
  • [3] Quantitative Ultrashort Echo Time (UTE) MRI of Human Cortical Bone: Correlation With Porosity and Biomechanical Properties
    Bae, Won C.
    Chen, Peter C.
    Chung, Christine B.
    Masuda, Koichi
    D'Lima, Darryl
    Du, Jiang
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (04) : 848 - 857
  • [4] Radiofrequency Pulses for Simultaneous Short T2 Excitation and Long T2 Suppression
    Carl, Michael
    Bydder, Mark
    Du, Jiang
    Han, Eric
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 531 - 537
  • [5] Optimization of RF Excitation to Maximize Signal and T2 Contrast of Tissues With Rapid Transverse Relaxation
    Carl, Michael
    Bydder, Mark
    Du, Jiang
    Takahashi, Atsushi
    Han, Eric
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 481 - 490
  • [6] Cancer interaction with the bone microenvironment - A workshop of the National Institutes of Health Tumor Microenvironment Study Section
    Cher, ML
    Towler, DA
    Rafii, S
    Rowley, D
    Donahue, HJ
    Keller, E
    Herlyn, M
    Cho, EA
    Chung, LWK
    [J]. AMERICAN JOURNAL OF PATHOLOGY, 2006, 168 (05) : 1405 - 1412
  • [7] Multipoint mapping for imaging of semi-solid materials
    Fernández-Seara, MA
    Wehrli, SL
    Wehrli, FW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2003, 160 (02) : 144 - 150
  • [8] Effects of formalin fixation and collagen cross-linking on T2 and magnetization transfer in bovine nasal cartilage
    Fishbein, Kenneth W.
    Gluzband, Yehezkiel A.
    Kaku, Masaru
    Ambia-Sobhan, Hasina
    Shapses, Sue A.
    Yamauchi, Mitsuo
    Spencer, Richard G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) : 1000 - 1011
  • [9] Magnetic resonance imaging of short T2 components in tissue
    Gatehouse, PD
    Bydder, GM
    [J]. CLINICAL RADIOLOGY, 2003, 58 (01) : 1 - 19
  • [10] FAST IMAGING IN LIQUIDS AND SOLIDS WITH THE BACK-PROJECTION LOW-ANGLE SHOT (BLAST) TECHNIQUE
    HAFNER, S
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (07) : 1047 - 1051