Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat

被引:60
作者
Bhide, Ashlesha [1 ]
Muthukumar, Sriram [2 ]
Saini, Amreek [1 ]
Prasad, Shalini [1 ]
机构
[1] Univ Texas Dallas, Dept Bioengn, 800 West Campbell Rd, Richardson, TX 75080 USA
[2] Enlisense LLC, 1813 Audubon Pond Way, Allen, TX 75013 USA
基金
美国国家卫生研究院;
关键词
STABILITY; CONSUMPTION; PROTEIN; FILMS;
D O I
10.1038/s41598-018-24543-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A lancet-free, label-free biosensor for simultaneous detection of sweat glucose and alcohol was demonstrated using zinc oxide thin films integrated into a nanoporous flexible electrode system. Sensing was achieved from perspired human sweat at low volumes (1-3 mu L), comparable to ambient conditions without external stimulation. Zinc oxide thin film electrodes were surface functionalized with alcohol oxidase enzyme and with glucose oxidase enzyme towards developing an affinity biosensor specific to the physiological relevant range of alcohol comprising of 0-2 drinks (0-50 mg/dl) and physiologically relevant range of glucose ranging from hypo-to hyper-glycaemia (50-130 mg/dl) in perspired human sweat. Sensing was achieved by measuring impedance changes associated with alcohol and glucose binding onto the sensor interface using electrochemical impedance spectroscopy with a dynamic range from 0.01-200 mg/dl and a limit of detection of 0.01 mg/dl for alcohol in human sweat. Sensor calibration in synthetic sweat containing interferents (25-200 mg/dl) and comparison using regression and Bland-Altman analysis of sweat sensor performance was done with BACtrack (R). Combinatorial detection of glucose and ethanol in perspired human sweat and comparison of sweat sensor performance with Accu-Chek (R) blood glucose monitoring system that we expect would be relevant for pre-diabetics and diabetics for monitoring their glucose levels and alcohol consumption.
引用
收藏
页数:11
相关论文
共 37 条
[1]  
Alromaihi D., 2012, Clinical Diabetes, V30, P120, DOI [10.2337/diaclin.30.3.120, DOI 10.2337/DIACLIN.30.3.120]
[2]  
Armbruster D.A., 2008, Clin. Biochem. Rev, V29
[3]   ALCOHOL, GLUCOSE-METABOLISM AND DIABETES [J].
AVOGARO, A ;
TIENGO, A .
DIABETES-METABOLISM REVIEWS, 1993, 9 (02) :129-146
[4]   Amperometric alcohol sensors based on protein multilayers composed of avidin and biotin-labeled alcohol oxidase [J].
Du, XY ;
Anzai, J ;
Osa, T ;
Motohashi, R .
ELECTROANALYSIS, 1996, 8 (8-9) :813-816
[5]   Deconvolving an estimate of breath measured blood alcohol concentration from biosensor collected transdermal ethanol data [J].
Dumett, M. A. ;
Rosen, I. G. ;
Sabat, J. ;
Shaman, A. ;
Tempelman, L. ;
Wang, C. ;
Swift, R. M. .
APPLIED MATHEMATICS AND COMPUTATION, 2008, 196 (02) :724-743
[6]  
Emanuele NV, 1998, ALCOHOL HEALTH RES W, V22, P211
[7]  
Fulati A., 2009, SENSORS, V9
[8]   A novel non-invasive electrochemical biosensing device for in situ determination of the alcohol content in blood by monitoring ethanol in sweat [J].
Gamella, M. ;
Campuzano, S. ;
Manso, J. ;
de Rivera, G. Gonzalez ;
Lopez-Colino, F. ;
Reviejo, A. J. ;
Pingarron, J. M. .
ANALYTICA CHIMICA ACTA, 2014, 806 :1-7
[9]  
Gandhi Malay., 2014, The Future of Biosensing Wearables
[10]   Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis [J].
Gao, Wei ;
Emaminejad, Sam ;
Nyein, Hnin Yin Yin ;
Challa, Samyuktha ;
Chen, Kevin ;
Peck, Austin ;
Fahad, Hossain M. ;
Ota, Hiroki ;
Shiraki, Hiroshi ;
Kiriya, Daisuke ;
Lien, Der-Hsien ;
Brooks, George A. ;
Davis, Ronald W. ;
Javey, Ali .
NATURE, 2016, 529 (7587) :509-+