Effect of geo-climatic conditions and pipe material on heating performance of earth-air heat exchangers

被引:29
作者
Lekhal, Mohammed Cherif [1 ]
Benzaama, Mohammed-Hichem [2 ]
Kindinis, Andrea [3 ]
Mokhtari, Abderahmane-Mejedoub [4 ]
Belarbi, Rafik [5 ]
机构
[1] Univ Gustave Eiffel, CNRS, UMR 8208, MSME Lab, F-77420 Marne La Vallee, France
[2] Lab Rech ESITC Caen, ComUE, 1 Rue Pierre & Marie Curie, F-14610 Epron, France
[3] UPE, Inst Rech Constructibilite, ESTP, 28 Ave President Wilson, F-94230 Cachan, France
[4] Univ Sci & Technol, LMST Lab, Oran 31000, Algeria
[5] Univ la Rochelle, CNRS, UMR 7356, LaSIE Lab, F-17042 La Rochelle, France
关键词
Earth-air heat exchangers (EAHEs); Heating performance; Pipe material; Sensitivity analysis; Operating feasibility; THERMAL PERFORMANCE; EAHE SYSTEMS; ENERGY; BUILDINGS; DESIGN; MODEL;
D O I
10.1016/j.renene.2020.08.044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Climatological and geological site classification intended for Earth-Air Heat Exchanger Technology (EAHE) is an important factor in the design, implementation and optimal operation of such system. In this context, this paper presents an investigation on the heating performance and operating feasibility of two EAHEs in three different geo-climatic regions in Algeria. First, the performances of the EAHEs were experimentally studied in the temperate Oran climate and the corresponding results were used for validation of the numerical part. The experiment allowed to analyze the effect of the pipe material on the performance of the two EAHEs that are made of different materials (PVC and Zinc). After validation of the numerical part, the study was extended to three different climates including a temperate climate for Oran, an arid climate for Bechar and a steppe climate for El-Bayadh cities. For these climates, the heating study is rarely considered in this context. Furthermore, a sensitivity analysis was conducted in order to evaluate the operating feasibility of the EAHEs in the considered regions. The results revealed that the Zinc EAHE is more efficient in a temperate climate with a COP of 9.5 than in an arid or steppe climate with a COP of 8.2 or 8.1, respectively. However, the PVC EAHE is much better in an arid climate with a COP of 9.4 than in a temperate or steppe climate with a COP of 7.6 or 8.4, respectively. Otherwise, both EAHEs exhibited similar behavior in a steppe climate. The results show that the thermal performance of EAHE mainly depends on geo-climatic conditions and the type of pipe material. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:22 / 40
页数:19
相关论文
共 37 条
[1]   Evaluation of an Earth-to-Air Heat Exchanger for the North-East of Iran with Semi-Arid Climate [J].
Abbaspour-Fard, Mohammad Hossein ;
Gholami, Adel ;
Khojastehpour, Mehdi .
INTERNATIONAL JOURNAL OF GREEN ENERGY, 2011, 8 (04) :499-510
[2]   Global greenhouse gas implications of land conversion to biofuel crop cultivation in arid and semi-arid lands - Lessons learned from Jatropha [J].
Achten, W. M. J. ;
Trabucco, A. ;
Maes, W. H. ;
Verchot, L. V. ;
Aerts, R. ;
Mathijs, E. ;
Vantomme, P. ;
Singh, V. P. ;
Muys, B. .
JOURNAL OF ARID ENVIRONMENTS, 2013, 98 :135-145
[3]  
[Anonymous], 2018, GLOBAL STATUS REPORT
[4]  
[Anonymous], 2014, METEONORM V7 0 22 8, DOI [10.5860/choice.36-6337, DOI 10.5860/CHOICE.36-6337]
[5]   Simple and accurate model for the ground heat exchanger of a passive house [J].
Badescu, Viorel .
RENEWABLE ENERGY, 2007, 32 (05) :845-855
[6]   Performance analysis of earth-pipe-air heat exchanger for summer cooling [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2010, 42 (05) :645-648
[7]   Performance analysis of earth-pipe-air heat exchanger for winter heating [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2009, 41 (11) :1151-1154
[8]   Experimental and analytical studies of earth-air heat exchanger (EAHE) systems in India: A review [J].
Bisoniya, Trilok Singh ;
Kumar, Anil ;
Baredar, Prashant .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 19 :238-246
[9]   Performance evaluation and life cycle cost analysis of earth to air heat exchanger integrated with adobe building for New Delhi composite climate [J].
Chel, Arvind ;
Tiwari, G. N. .
ENERGY AND BUILDINGS, 2009, 41 (01) :56-66
[10]   Experimental study of an earth to air heat exchanger (EAHE) for warm humid climatic conditions [J].
Diaz-Hernandez, H. P. ;
Macias-Melo, E., V ;
Aguilar-Castro, K. M. ;
Hernandez-Perez, I ;
Xaman, J. ;
Serrano-Arellano, J. ;
Lopez-Manrique, L. M. .
GEOTHERMICS, 2020, 84