COMPARISON OF GLUCOSE POINT-OF-CARE VALUES WITH LABORATORY VALUES IN CRITICALLY ILL PATIENTS

被引:25
作者
Shearer, Anna [1 ]
Boehmer, Marilyn [1 ]
Closs, Melanie [1 ]
Dela Rosa, Rosalina [1 ]
Hamilton, Jean [1 ]
Horton, Karen [1 ]
McGrath, Rose [1 ]
Schulman, Christine
机构
[1] Providence St Vincents Med Ctr, Intens Care Unit, Portland, OR 97225 USA
关键词
INTENSIVE INSULIN THERAPY; ARTERIAL-BLOOD; METERS; HEMATOCRIT; CAPILLARY; ACCURACY; REFLECTANCE; AGREEMENT; MONITORS; PH;
D O I
10.4037/ajcc2009448
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Blood from central venous or arterial catheters as well as from fingersticks is often used for point-of-care glucose testing. Objectives To compare glucose values obtained with a point-of-care device for catheter and fingerstick blood samples with values obtained by clinical laboratory analysis of a catheter blood sample. Methods A method-comparison design was used. Point-of-care values for fingerstick and catheter blood samples were compared with laboratory values for blood from catheters in a convenience sample of 63 critically ill patients. Device bias and precision were calculated and graphed according to the Bland-Altman method, and a t test was used to determine differences in glucose values for the 2 methods. Results Laboratory glucose values for blood from a catheter sample differed significantly from point-of-care values for blood from a fingerstick (t(1,61) = 5.01; P < .001) and from a catheter (t(1,61) = 3.91; P < .001). Bias and precision for the point-of-care device was large (fingerstick, 8.7 and 13.7; catheter, 7.0 and 14.0); 20% of the values differed from the laboratory glucose values by more than 20 mg/dL. Point-of-care glucose values for fingerstick and catheter samples did not differ (P = .41). Conclusions Glucose values obtained with a point-of-care device differ significantly from those obtained by laboratory analysis. The magnitude of these differences calls into question the widespread practice of using point-of-care glucose testing to guide insulin titration for tight glucose control. Errors in dosing could easily be made because of the large bias and precision associated with a point-of-care device. (American Journal of Critical Care. 2009; 18: 224-230)
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [41] Glucose control in critically ill patients
    Flower, O.
    Finfer, S.
    INTERNAL MEDICINE JOURNAL, 2012, 42 (01) : 4 - 6
  • [42] Critical Care Glucose Point-of-Care Testing
    Narla, S. N.
    Jones, M.
    Hermayer, K. L.
    Zhu, Y.
    ADVANCES IN CLINICAL CHEMISTRY, VOL 76, 2016, 76 : 97 - 121
  • [43] Comparison of a Point-of-care Cholesterol Meter With a Reference Laboratory Analyzer in Companion Psittaciformes
    Barboza, Trinita
    Beaufrere, Hugues
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2019, 33 (01) : 7 - 14
  • [44] Evaluation of point-of-care capillary and venous blood glucose concentrations in hospitalized neonatal foals
    Moreira, Ana Sofia Dias
    Weng, Hsin-Yi
    Hostnik, Laura D.
    Beasley, Erin M.
    Peek, Simon F.
    Munsterman, Amelia S.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2024, 34 (06) : 570 - 578
  • [45] Erroneous Causes of Point-of-Care Glucose Readings
    Majewski, Joseph
    Risler, Zachary
    Gupta, Kanika
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [46] Comparison of glucose concentrations in canine whole blood, plasma, and serum measured with a veterinary point-of-care glucometer
    Suchowersky, Natalie D.
    Carlson, Elizabeth A.
    Lee, Hollie P.
    Behrend, Ellen N.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2021, 33 (04) : 695 - 702
  • [47] Point-of-care glucose monitoring on the neonatal unit
    Makaya, Tafadzwa
    Memmott, Alan
    Bustani, Porus
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2012, 48 (04) : 342 - 346
  • [48] Quality of Glucose Measurement with Blood Glucose Meters at the Point-of-Care: Relevance of Interfering Factors
    Heinemann, Lutz
    DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (11) : 847 - 857
  • [49] Comparison of point-of-care device DiaSpect against the HemoCue and laboratory analyser in an ICU population
    Salmond, B.
    Rodseth, R. N.
    Farina, Z.
    von Randen, R. P.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2021, 27 (02) : 99 - 103
  • [50] Effect of hematocrit, galactose and ascorbic acid on the blood glucose readings of three point-of-care glucometers
    Albloui, Fawaz
    John, James
    Alghamdi, Osama
    Alseraye, Faisal
    Alqahtani, Abdullah
    Tamimi, Waleed
    Albloshi, Abdullah
    Aldakheel, Fahad M.
    Mateen, Ayesha
    Syed, Rabbani
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2022, 82 (7-8) : 563 - 570