COMPARISON OF GLUCOSE POINT-OF-CARE VALUES WITH LABORATORY VALUES IN CRITICALLY ILL PATIENTS

被引:25
|
作者
Shearer, Anna [1 ]
Boehmer, Marilyn [1 ]
Closs, Melanie [1 ]
Dela Rosa, Rosalina [1 ]
Hamilton, Jean [1 ]
Horton, Karen [1 ]
McGrath, Rose [1 ]
Schulman, Christine
机构
[1] Providence St Vincents Med Ctr, Intens Care Unit, Portland, OR 97225 USA
关键词
INTENSIVE INSULIN THERAPY; ARTERIAL-BLOOD; METERS; HEMATOCRIT; CAPILLARY; ACCURACY; REFLECTANCE; AGREEMENT; MONITORS; PH;
D O I
10.4037/ajcc2009448
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Blood from central venous or arterial catheters as well as from fingersticks is often used for point-of-care glucose testing. Objectives To compare glucose values obtained with a point-of-care device for catheter and fingerstick blood samples with values obtained by clinical laboratory analysis of a catheter blood sample. Methods A method-comparison design was used. Point-of-care values for fingerstick and catheter blood samples were compared with laboratory values for blood from catheters in a convenience sample of 63 critically ill patients. Device bias and precision were calculated and graphed according to the Bland-Altman method, and a t test was used to determine differences in glucose values for the 2 methods. Results Laboratory glucose values for blood from a catheter sample differed significantly from point-of-care values for blood from a fingerstick (t(1,61) = 5.01; P < .001) and from a catheter (t(1,61) = 3.91; P < .001). Bias and precision for the point-of-care device was large (fingerstick, 8.7 and 13.7; catheter, 7.0 and 14.0); 20% of the values differed from the laboratory glucose values by more than 20 mg/dL. Point-of-care glucose values for fingerstick and catheter samples did not differ (P = .41). Conclusions Glucose values obtained with a point-of-care device differ significantly from those obtained by laboratory analysis. The magnitude of these differences calls into question the widespread practice of using point-of-care glucose testing to guide insulin titration for tight glucose control. Errors in dosing could easily be made because of the large bias and precision associated with a point-of-care device. (American Journal of Critical Care. 2009; 18: 224-230)
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [21] Point-of-care Laboratory Testing
    Gauglitz, Guenter
    Luppa, Peter B.
    CHEMIE IN UNSERER ZEIT, 2009, 43 (05) : 308 - 318
  • [22] A Multicenter Evaluation of a Point-of-Care Blood Glucose Meter System in Critically III Patients
    Nichols, James H.
    Brandler, Ethan S.
    Fantz, Corinne R.
    Fisher, Kimberley
    Goodman, Michael D.
    Headden, Gary
    Hoppensteadt, Debra
    Matika, Ryan
    Peacock, W. Frank
    Rodrigo, John
    Schutzenmeister, Andre
    Swanson, Jonathan R.
    Canada-Vilalta, Cristina
    Miles, Gabrielle
    Tran, Nam
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (04) : 820 - 833
  • [23] Point-of-Care Glucose Critical Values A Q-Probes Study Involving 50 Health Care Facilities and 2349 Critical Results
    Schifman, Ron B.
    Howanitz, Peter J.
    Souers, Rhona J.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2016, 140 (02) : 119 - 124
  • [24] Acute kidney injury detection with additional point-of-care creatinine vs central laboratory serum creatinine measurement in critically ill patients
    White, Kyle C.
    Meyer, Jason
    Laupland, Kevin B.
    Senthuran, Siva
    Shekar, Kiran
    Mccullough, James
    Bellomo, Rinaldo
    JOURNAL OF CRITICAL CARE, 2025, 88
  • [25] Significant interference on specific point-of-care glucose measurements due to high dose of intravenous vitamin C therapy in critically ill patients
    ten Berge, Daan
    Muller, Wim
    Beishuizen, Albertus
    Cornet, Alexander Daniel
    Slingerland, Robbert
    Krabbe, Johannes
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (05) : E197 - E199
  • [26] Evaluation of a continuous glucose monitoring system compared with an in-house standard laboratory assay and a handheld point-of-care glucometer in critically ill neonatal foals
    Hug, Sophie A.
    Riond, Barbara
    Schwarzwald, Colin C.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2013, 23 (04) : 408 - 415
  • [27] A Comparison Study Between Point-of-Care Testing Systems and Central Laboratory for Determining Blood Glucose in Venous Blood
    Wei, Huiping
    Lan, Fang
    He, Qitian
    Li, Haiwei
    Zhang, Fuyong
    Qin, Xue
    Li, Shan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (03)
  • [28] Point-of-Care Glucose and Ketone Monitoring
    Chong, Siew Kim
    Reineke, Erica L.
    TOPICS IN COMPANION ANIMAL MEDICINE, 2016, 31 (01) : 18 - 26
  • [29] Performance Evaluation of a Glucose Monitoring System for Point-of-Care Testing With the Critically Ill Patient Population-A Multicenter Study
    Louie, Richard F.
    Curtis, Corbin M.
    Toffaletti, John G.
    Handel, Elizabeth A.
    Slingerland, Robbert J.
    Fokkert, Marion J.
    Muller, Wim
    Weinert, Sandra E.
    Lee, Debra M.
    Kotagiri, Sheela
    POINT OF CARE, 2015, 14 (01): : 37 - 41
  • [30] Accuracy of Point-of-Care Blood Glucose Level Measurements in Critically Ill Patients with Sepsis Receiving High-Dose Intravenous Vitamin C
    Smith, Kathryn E.
    Brown, Caitlin S.
    Manning, Bridget M.
    May, Teresa
    Riker, Richard R.
    Lerwick, Patricia A.
    Hayes, Timothy L.
    Fraser, Gilles L.
    PHARMACOTHERAPY, 2018, 38 (11): : 1155 - 1161