Characterizing coronary motion and its effect on MR coronary angiography - Initial experience

被引:5
作者
Al-Kwifi, Osama [1 ]
Stainsby, Jeffrey [1 ]
Foltz, Warren D. [1 ]
Sussman, Marshall S. [1 ]
Huang, Yuexi [1 ]
Wright, Graham A. [1 ]
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Med Imaging Res, Imaging Res Program, Toronto, ON M4N 3M5, Canada
关键词
coronary MR angiography; coronary artery motion; magnetic resonance angiography; spiral acquisition; point-spread function;
D O I
10.1002/jmri.20697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize coronary artery motion as a prescan procedure to select the optimum scan setting that will produce high-resolution images. Materials and Methods: A 2D real-time scan was used to image the major coronary arteries during breath-holding and free-breathing conditions. With the use of the 2D images, motion displacement of each artery was measured along three axes. Motion data obtained from a computer simulation were used to estimate point-spread functions (PSFs) associated with different high-resolution spiral acquisition strategies, including real-time, cardiac-gated, and respiratory-gated acquisitions. The simulation output determined the optimum acquisition and scan parameters that would produce the highest-spatial-resolution images of the coronary arteries. The effects of heart rate (HR), extended breath-holding, and number of slices per heart cycle were also investigated. Results: Substantial variations in coronary motion occur among individuals, which directly influences the optimum parameters for a high-resolution scan. Lower HRs and longer breath-holds yield substantially increased spatial resolution. The maximum number of slices per heart cycle can also be determined to minimize slice-to-slice distortion. Conclusion: The results suggest that to obtain high-resolution coronary images, one should perform a prescan coronary-motion characterization for each individual so that the scan parameters can be optimized before data acquisition.
引用
收藏
页码:842 / 850
页数:9
相关论文
共 22 条
[1]  
ALKWIFI O, 2003, P 15 ANN M INT MR AN
[2]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[3]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[4]   MAGNETIC-RESONANCE IMAGING WITH RESPIRATORY GATING - TECHNIQUES AND ADVANTAGES [J].
EHMAN, RL ;
MCNAMARA, MT ;
PALLACK, M ;
HRICAK, H ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1175-1182
[5]   Optimized spiral imaging for measurement of myocardial T2 relaxation [J].
Foltz, WD ;
Al-Kwifi, O ;
Sussman, MS ;
Stainsby, JA ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1089-1097
[6]  
Haacke EM, 1999, MAGNETIC RESONANCE I
[7]  
Hardy CJ, 2000, MAGNET RESON MED, V44, P940, DOI 10.1002/1522-2594(200012)44:6<940::AID-MRM16>3.0.CO
[8]  
2-F
[9]   Optimal electrocardiographically triggered phase for reducing motion artifact at electron-beam CT in the coronary artery [J].
He, S ;
Dai, RP ;
Chen, Y ;
Bai, H .
ACADEMIC RADIOLOGY, 2001, 8 (01) :48-56
[10]   SELECTION OF A CONVOLUTION FUNCTION FOR FOURIER INVERSION USING GRIDDING [J].
JACKSON, JI ;
MEYER, CH ;
NISHIMURA, DG ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :473-478