Electrical stimulation rate effects on speech perception in cochlear implants

被引:28
作者
Arora, Komal [1 ]
Dawson, Pam [2 ]
Dowell, Richard [1 ]
Vandali, Andrew [2 ]
机构
[1] Univ Melbourne, Dept Otolaryngol, Melbourne 3002, Australia
[2] HEARing Cooperat Res Ctr CRC, Melbourne, Australia
关键词
Cochlear implant; Electrical stimulation rate; Speech perception; CODING STRATEGY; SYSTEM;
D O I
10.1080/14992020902858967
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
The objective of this study was to explore cochlear implant users' speech perception performance in quiet and in noise for low to moderate stimulation rates. Eight postlingually deaf adult users of the Nucleus CI24 cochlear implant (contour electrode array) using the ESPrit 3G speech processor participated in this study. Monosyllabic word recognition in quiet and sentence perception in noise was evaluated for low to moderate stimulation rates of 275, 350, 500, and 900 pulses-per-second/channel (pps/ch). All four stimulation rate programs were balanced for loudness. A repeated ABCD experimental design was employed. Take home practice was provided with each stimulation rate. Subjects also responded to a comparative questionnaire to examine their rate preference for a variety of listening situations. Results for six of the eight subjects showed no significant effect of rate for monosyllables in quiet. However, results for the sentence test in noise demonstrated improvements with 500 or 900 pps/ch stimulation rates in seven out of the eight subjects. Although there was not a close relationship between each subject's subjective preference and the rate program that provided best speech perception, most subjects indicated a preference for 500 pps/ch rate in noise.
引用
收藏
页码:561 / 567
页数:7
相关论文
共 19 条
  • [11] PITCH PERCEPTS ASSOCIATED WITH AMPLITUDE-MODULATED CURRENT PULSE TRAINS IN COCHLEAR IMPLANTEES
    MCKAY, CM
    MCDERMOTT, HJ
    CLARK, GM
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 96 (05) : 2664 - 2673
  • [12] Spectral and temporal cues in cochlear implant speech perception
    Nie, K
    Barco, A
    Zeng, FG
    [J]. EAR AND HEARING, 2006, 27 (02) : 208 - 217
  • [13] TEMPORAL RESPONSE PATTERNS OF AUDITORY-NERVE FIBERS TO ELECTRICAL-STIMULATION IN DEAFENED SQUIRREL-MONKEYS
    PARKINS, CW
    [J]. HEARING RESEARCH, 1989, 41 (2-3) : 137 - 168
  • [14] REVISED CNC LISTS FOR AUDITORY TESTS
    PETERSON, GE
    LEHISTE, I
    [J]. JOURNAL OF SPEECH AND HEARING DISORDERS, 1962, 27 (01): : 62 - 70
  • [15] Clinical evaluation of higher stimulation rates in the nucleus research platform 8 system
    Plant, Kerrie
    Holden, Laura
    Skinner, Margo
    Arcaroli, Jennifer
    Whitford, Lesley
    Law, Mary-Ann
    Nel, Esti
    [J]. EAR AND HEARING, 2007, 28 (03) : 381 - 393
  • [16] Plant Kerrie L, 2002, Cochlear Implants Int, V3, P104, DOI 10.1179/cim.2002.3.2.104
  • [17] Speech perception as a function of electrical stimulation rate: Using the nucleus 24 cochlear implant system
    Vandali, AE
    Whitford, LA
    Plant, KL
    Clarke, GM
    [J]. EAR AND HEARING, 2000, 21 (06) : 608 - 624
  • [18] Effect of stimulation rate on speech perception in adult users of the Med-El CIS speech processing strategy
    Verschuur, CA
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2005, 44 (01) : 58 - 63
  • [19] Performance and preference for ACE stimulation rates obtained with nucleus RP 8 and freedom system
    Weber, B. P.
    Lai, W. K.
    Dillier, N.
    von Wallenberg, E. L.
    Killian, M. J. P.
    Pesch, J.
    Battmer, R. D.
    Lenarz, T.
    [J]. EAR AND HEARING, 2007, 28 (02) : 46S - 48S