Colorimetric Detection of Cr3+ in Aqueous Solution Based on Cofunctionalized Silver Nanoparticles Modified with 4-Nitrobenzenethiol and 4-Mercaptobenzoic Acid

被引:9
作者
Zhang, Zhikun [1 ]
Zhou, Ying [1 ]
Yang, Jing-Kui [1 ]
Wang, Peilong [2 ]
Su, Xiaoou
Zhao, Hong [1 ]
He, Yujian [1 ,3 ]
Cao, Zhiqin [4 ]
Luo, Maoqiang [4 ]
机构
[1] Univ Chinese Acad Sci, Sch Chem & Chem Engn, Beijing 100049, Peoples R China
[2] Chinese Acad Agr Sci, Inst Qual Stand & Testing Technol Agroprod, Key Lab Groprod Safety & Qual, Minist Agr, Beijing 100081, Peoples R China
[3] Peking Univ, State Key Lab Nat & Biomimet Drugs, Beijing 100191, Peoples R China
[4] Beijing Kangda Environm Co Ltd, Beijing 102488, Peoples R China
基金
中国国家自然科学基金;
关键词
Silver nanoparticles; Cr3+; 4-nitrobenzenethiol; 4-mercaptobenzoic acid; colorimetric; SELECTIVE DETECTION; GOLD NANOPARTICLES; CHROMIUM; SPECIATION; CR(III); CR(VI); SPECTROMETRY; COMPLEXES;
D O I
10.1142/S1793292015500952
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A new method has been proposed to realize the visual detection of Cr3+ using 4-nitrobenzenethiol (4-NBT) and 4-mercaptobenzoic acid (4-MBA) modified silver nanoparticles (AgNPs). The presence of Cr3+ induces the aggregation of AgNPs through cooperative metal-ligand interaction, resulting in a color change from bright yellow to purple. Consequently, Cr3+ could be monitored by colorimetric response of AgNPs by a UV-Vis spectrophotometer or even naked eyes. We firstly used ethylene diamine tetraacetic acid (EDTA) as a masking agent to selectively detect Cr3+, and other metal ions have little influence on the Cr3+-AgNPs system. The cofunctionalized AgNPs exhibited a highly sensitive detection limit of Cr3+, which is as low as 5 x 10(-9) mol L-1, and the absorbance ratio (A(600nm)/A(387nm)) is linear with the concentration of Cr3+ ranging from 5 x 10(-9) mol L-1 to 2 x 10(-6) mol L-1 with a coefficient of 0.993. Particularly, the sensor has been further evaluated to monitor the concentration of Cr3+ in drinking water, the recovery was in good agreement with those obtained by ICP-MS, indicating that this proposed method is successfully applied in real samples.
引用
收藏
页数:8
相关论文
共 27 条
  • [1] Chromium, glucose intolerance and diabetes
    Anderson, RA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 1998, 17 (06) : 548 - 555
  • [2] SIMULTANEOUS DETERMINATION OF CR(III), FE(III), CU(II) AND PB(II) AS UV-ABSORBING EDTA COMPLEXES BY CAPILLARY ZONE ELECTROPHORESIS
    BARAJ, B
    MARTINEZ, M
    SASTRE, A
    AGUILAR, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 695 (01) : 103 - 111
  • [3] Comparison of standard and reaction cell inductively coupled plasma mass spectrometry in the determination of chromium and selenium species by HPLC-ICP-MS
    Bednar, A. J.
    Kirgan, R. A.
    Jones, W. T.
    [J]. ANALYTICA CHIMICA ACTA, 2009, 632 (01) : 27 - 34
  • [4] Detection of the nanomolar level of total Cr[(III) and (VI)] by functionalized gold nanoparticles and a smartphone with the assistance of theoretical calculation models
    Chen, Wenwen
    Cao, Fengjing
    Zheng, Wenshu
    Tian, Yue
    Xianyu, Yunlei
    Xu, Peng
    Zhang, Wei
    Wang, Zhuo
    Deng, Ke
    Jiang, Xingyu
    [J]. NANOSCALE, 2015, 7 (05) : 2042 - 2049
  • [5] Detection of mismatched DNAs via the binding affinity of MutS using a gold nanoparticle-based competitive colorimetric method
    Cho, Minseon
    Han, Min Su
    Ban, Changill
    [J]. CHEMICAL COMMUNICATIONS, 2008, (38) : 4573 - 4575
  • [6] Speciation of chromium in mineral waters and salinas by solid-phase extraction and graphite furnace atomic absorption spectrometry
    Chwastowska, J
    Skwara, W
    Sterlinska, E
    Pszonicki, L
    [J]. TALANTA, 2005, 66 (05) : 1345 - 1349
  • [7] Simple fluorescence-based detection of Cr(III) and Cr(VI) using unmodified gold nanoparticles
    Elavarasi, M.
    Alex, Sruthi Ann
    Chandrasekaran, N.
    Mukherjee, Amitava
    [J]. ANALYTICAL METHODS, 2014, 6 (24) : 9554 - 9560
  • [8] EFFECT OF TRIVALENT CHROMIUM ON GLUCOSE TOLERANCE
    GLINSMAN.WH
    MERTZ, W
    [J]. METABOLISM, 1966, 15 (06): : 510 - &
  • [9] Chromium determination and speciation since 2000
    Gomez, V.
    Callao, M. P.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (10) : 1006 - 1015
  • [10] Catalytic adsorptive stripping voltammetric determination of Cr(VI) in EDTA extracts from solid samples
    Grabarczyk, M
    [J]. ELECTROCHIMICA ACTA, 2006, 51 (11) : 2333 - 2337