Intraoperative transesophageal echocardiography is beneficial for hemodynamic stabilization during left ventricular assist device implantation in children

被引:8
作者
Scohy, Thierry V. [1 ]
Gommers, Diederik [1 ]
Maat, Alexander P. W. M. [2 ]
Dejong, Peter L. [2 ]
Bogers, Ad J. J. C. [2 ]
Hofland, Jan [1 ]
机构
[1] Erasmus MC, Dept Anaesthesiol, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiothorac Surg, NL-3015 CE Rotterdam, Netherlands
关键词
intraoperative; transesophageal echocardiography; children; LVAD; MANAGEMENT;
D O I
10.1111/j.1460-9592.2008.02917.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Mechanical circulatory support, with a left ventricular assist device (LVAD) is used in an increasing number of children for treatment of advanced heart failure as bridge-to-transplant. To date no data are available and no studies have defined the role of intraoperative transesophageal echocardiography (TEE) for hemodynamic stabilization during Centrimag Levitronix centrifugal pump implantation in children. Children with therapy resistant heart failure, undergoing LVAD implantation using Berlin Heart Excor pediatric cannula connected to a Levitronix Centrifumag pump, are intraoperatively monitored using an Oldelft micromultiplane TEE. Intraoperative TEE is specially used to monitor right ventricular (RV) and left ventricular (LV) function, correct position of the cannulas and response to pharmacological treatment. In five consecutive patients RV function was assessed by TEE after starting LVAD Levitronix centrifugal pump. Initial RV failure presents with RV dilation and LV collapse. After titration of vasopressor and inotropic agents, RV contractility improved and thereby the filling of the LV. In one child, despite those measures the RV showed no improvement by TEE and a Levitronix right ventricular assist device to support the RV function was implanted as well. All patients could hemodynamically be stabilized before transport to the intensive care unit. The complex interaction of the RV and LV function and correct positioning of the cannula, during LVAD implantation in children with end-stage cardiac failure is improved by simultaneous visualization of cardiac performance of both ventricles and cannula positioning by means of intraoperative multiplane TEE.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 9 条
[1]  
Catena E, 2007, Minerva Cardioangiol, V55, P247
[2]   Perioperative echocardiographic examination for ventricular assist device implantation [J].
Chumnanvej, Siriluk ;
Wood, Malissa J. ;
MacGillivray, Thomas E. ;
Melo, Marcos F. Vidal .
ANESTHESIA AND ANALGESIA, 2007, 105 (03) :583-601
[3]   Connecting the Centrimag Levitronix pump to Berlin Heart Excor cannulae; A new approach to bridge to bridge [J].
Maat, Alexander P. W. M. ;
van Thiel, Robert J. ;
Dalinghaus, Michiel ;
Bogers, Ad J. J. C. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (01) :112-115
[4]   Clinical utility of echocardiography in the management of implantable ventricular assist devices [J].
Scalia, GM ;
McCarthy, PM ;
Savage, RM ;
Smedira, NG ;
Thomas, JD .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (08) :754-763
[5]   Intraoperative evaluation of micromultiplane transesophageal echocardiographic probe in surgery for congenital heart disease [J].
Scohy, Thierry V. ;
Gommers, Diederik ;
Harkel, A. Derk Jan ten ;
Deryck, Yvon ;
McGhie, Jackie ;
Bogers, Ad. J. J. C. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (04) :241-246
[6]   Management of pediatric patients after implantation of the Berlin Heart EXCOR ventricular assist device [J].
Stiller, Brigitte ;
Lemmer, Julia ;
Schubert, Stephan ;
Ewert, Peter ;
Schulze-Neick, Ingram ;
Huebler, Michael ;
Redlin, Matthias ;
Berger, Felix ;
Hetzer, Roland .
ASAIO JOURNAL, 2006, 52 (05) :497-500
[7]   Transesophageal echocardiography: An objective tool in defining maximum ventricular response to intravenous fluid therapy [J].
Swenson, JD ;
Harkin, C ;
Pace, NL ;
Astle, K ;
Bailey, P .
ANESTHESIA AND ANALGESIA, 1996, 83 (06) :1149-1153
[8]   The use of transesophageal echocardiography for preload assessment in critically ill patients [J].
Tousignant, CP ;
Walsh, F ;
Mazer, CD .
ANESTHESIA AND ANALGESIA, 2000, 90 (02) :351-355
[9]  
Wang Y, 1992, J Clin Anesth, V4, P4, DOI 10.1016/0952-8180(92)90111-D