Intra- and Interrater Reliability of Ultrasound Assessment of Gastric Volume

被引:139
作者
Kruisselbrink, Richelle [1 ]
Arzola, Cristian [2 ]
Endersby, Ryan [1 ]
Tse, Cyrus [3 ]
Chan, Vincent [1 ]
Perlas, Anahi [1 ]
机构
[1] Univ Toronto, Toronto Western Hosp, Univ Hlth Network, Toronto, ON M5T 2S8, Canada
[2] Univ Toronto, Mt Sinai Hosp, Toronto, ON M5G 1X5, Canada
[3] Univ Hlth Network, Toronto Western Hosp, Toronto, ON, Canada
关键词
CONCORDANCE CORRELATION-COEFFICIENT; AGREEMENT; CLASSIFICATION; ASPIRATION; TIME;
D O I
10.1097/ALN.0000000000000193
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Gastric sonography can provide information about gastric content and volume that can help determine aspiration risk at the bedside. The primary objective of this study is to assess the intrarater and interrater reliability of a previously validated method of gastric volume assessment based on gastric antral area. The secondary objective is to evaluate the agreement between two different methods to measure gastric antral area. Methods: Three independent raters performed a standardized gastric ultrasound assessment in healthy subjects who had been randomly allocated to ingest a predetermined volume of clear fluid (apple juice) from 0 to 400 ml. Each rater measured the gastric antral area, using twice the two-diameter method and twice the free-tracing method. The rater order was allocated at random and raters were unaware of the volume ingested and of one-another's measurements. The Guidelines for Reporting Reliability and Agreement Studies were followed for conducting and reporting this study. Results: Twenty-two volunteers were studied. Ultrasound assessment of antral cross-sectional area and volume was found to have nearly perfect intrarater and interrater reliability (correlation coefficient >0.8) with maximum differences within 13%. A Bland-Altman analysis suggests that the free-tracing method and the two-diameter method are essentially equivalent, within a clinically acceptable level of agreement. Conclusions: Ultrasound assessment of gastric volume by clinical anesthesiologists is highly reproducible with high intrarater and interrater reliability. The free-tracing method to measure antral cross-sectional area is equivalent to the two-diameter method.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 28 条
[1]  
Arzola C, 2013, CAN J ANESTH, V60, P771, DOI 10.1007/s12630-013-9974-y
[2]   Assessment of the intraobserver variability in the measurement of fetal cardiothoracic ratio using ellipse and diameter methods [J].
Awadh, A. M. A. ;
Prefumo, F. ;
Bland, J. M. ;
Carvalho, J. S. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (01) :53-56
[3]   Evaluation of the Neer system of classification of proximal humeral fractures with computerized tomographic scans and plain radiographs [J].
Bernstein, J ;
Adler, LM ;
Blank, JE ;
Dalsey, RM ;
Williams, GR ;
Iannotti, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1371-1375
[4]   Interobserver and intraobserver reliability of the NICHD 3-Tier Fetal Heart Rate Interpretation System [J].
Blackwell, Sean C. ;
Grobman, William A. ;
Antoniewicz, Leah ;
Hutchinson, Maria ;
Bannerman, Cynthia Gyamfi .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 205 (04) :378.e1-378.e5
[5]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   MEASUREMENT OF GASTRIC-EMPTYING TIME BY REAL-TIME ULTRASONOGRAPHY [J].
BOLONDI, L ;
BORTOLOTTI, M ;
SANTI, V ;
CALLETTI, T ;
GAIANI, S ;
LABO, G .
GASTROENTEROLOGY, 1985, 89 (04) :752-759
[8]   Clinical Assessment of the Ultrasonographic Measurement of Antral Area for Estimating Preoperative Gastric Content and Volume [J].
Bouvet, Lionel ;
Mazoit, Jean-Xavier ;
Chassard, Dominique ;
Allaouchiche, Bernard ;
Boselli, Emmanuel ;
Benhamou, Dan .
ANESTHESIOLOGY, 2011, 114 (05) :1086-1092
[9]   THE LOWER ESOPHAGEAL SPHINCTER AND ANESTHESIA [J].
COTTON, BR ;
SMITH, G .
BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (01) :37-46
[10]  
Darwiche G, 1999, J ULTRAS MED, V18, P673