Measurement and comparison of bracket transfer accuracy of five indirect bonding techniques

被引:64
作者
Castilla, Ana E. [1 ]
Crowe, Jennifer J. [1 ]
Moses, J. Ryan [1 ]
Wang, Mansen [2 ]
Ferracane, Jack L. [3 ]
Covell, David A., Jr. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Orthodont, Portland, OR 97239 USA
[2] Banfield Pet Hosp, Portland, OR USA
[3] Oregon Hlth & Sci Univ, Dept Restorat Dent, Portland, OR 97239 USA
关键词
Indirect bonding; Bracket bonding accuracy; MECHANICAL-PROPERTIES; PLACEMENT;
D O I
10.2319/070113-484.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To measure and compare bracket transfer accuracy of five indirect bonding (IDB) techniques. Materials and Methods: Five IDB techniques were studied: double polyvinyl siloxane (double-PVS), double vacuum-form (double-VF), polyvinyl siloxane vacuum-form (PVS-VF), polyvinyl siloxane putty (PVS-putty), and single vacuum-form (single-VF). Brackets were bonded on 25 identical stone working models. IDB trays were fabricated over working models (n = 5 per technique) to transfer brackets to another 25 identical stone patient models. The mesiodistal (M-D), occlusogingival (O-G), and faciolingual (F-L) positions of each bracket were measured on the working and patient models using digital photography (M-D, O-G) and calipers (F-L). Paired t-tests were used to compare bracket positions between working and patient models, and analysis of variance was used to compare bracket transfer accuracy among the five techniques. Results: Between the working and patient models, double-VF had the most teeth with significant differences (n = 6) and PVS-VF the fewest (n = 1; P < .05). With one exception, all significant differences were <= 0.26 mm and most (65%) were <= 0.13 mm. When the techniques were compared, bracket transfer accuracy was similar for double-PVS, PVS-putty, and PVS-VF, whereas double-VF and single-VF showed significantly less accuracy in the O-G direction. Conclusions: Although overall differences in bracket position were relatively small, silicone-based trays had consistently high accuracy in transferring brackets, whereas methods that exclusively used vacuum-formed trays were less consistent.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 25 条
[1]   ASSESSMENT OF BRACKET PLACEMENT AND BOND STRENGTH WHEN COMPARING DIRECT BONDING TO INDIRECT BONDING TECHNIQUES [J].
AGUIRRE, MJ ;
KING, GJ ;
WALDRON, JM .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1982, 82 (04) :269-276
[2]  
[Anonymous], 1997, DENT MAT THEIR SELEC
[3]   A comparison of accuracy in bracket positioning between two techniques-localizing the centre of the clinical crown and measuring the distance from the incisal edge [J].
Armstrong, David ;
Shen, Gang ;
Darendeliler, M. Ali .
EUROPEAN JOURNAL OF ORTHODONTICS, 2007, 29 (05) :430-436
[4]  
Caldas Maria de Paula, 2007, Braz. oral res., V21, P330, DOI 10.1590/S1806-83242007000400009
[5]  
Dorfer S., 2006, KIEFERORTHOPADIE, V20, P91
[6]  
Galvão Maria Christina de Souza, 2012, Dental Press J. Orthod., V17, P115
[7]  
Guenthner T., 2007, Seminars in Orthodontics, V13, P58, DOI 10.1053/j.sodo.2006.11.007
[8]   Accounting for measurement error: A critical but often overlooked process [J].
Harris, Edwayd F. ;
Smith, Richayd N. .
ARCHIVES OF ORAL BIOLOGY, 2009, 54 :S107-S117
[9]  
Hodge T M, 2004, J Orthod, V31, P132, DOI 10.1179/146531204225020427
[10]  
Hodge T M, 2001, J Orthod, V28, P267