Fabrication of an X-ray microcalorimeter with an electrodeposited X-ray microabsorber

被引:0
|
作者
Kudo, H [1 ]
Sato, H [1 ]
Nakamura, T [1 ]
Arakawa, T [1 ]
Goto, E [1 ]
Shoji, S [1 ]
Homma, T [1 ]
Osaka, T [1 ]
Mitsuda, K [1 ]
Fujimoto, R [1 ]
Iyomoto, N [1 ]
Audley, MD [1 ]
Miyazaki, T [1 ]
Oshima, T [1 ]
Yamazaki, M [1 ]
Futamoto, K [1 ]
Takei, Y [1 ]
Ishisaki, Y [1 ]
Kagei, T [1 ]
Hiroike, T [1 ]
Ohashi, T [1 ]
Yamasaki, NY [1 ]
Kushino, A [1 ]
Kuroda, Y [1 ]
Onishi, M [1 ]
Goto, M [1 ]
机构
[1] Waseda Univ, Shinjuku Ku, Tokyo 16985555, Japan
来源
LOW TEMPERATURE DETECTORS | 2002年 / 605卷
关键词
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
For the next generation of astronomical X-ray imaging detectors, arrays with large numbers of microstructures (similar to1000 pixels) will be required. To meet this requirement, a tin absorber for an X-ray microcalorimeter, which has a so-called "mushroom" shape, is fabricated by electrodeposition and polishing. This method enables the fabrication of a large number of arrayed microcalorimeters. Details of the fabrication process, the characteristics of the absorber and the fabricated microcalorimeters are reported.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 50 条
  • [31] Fabrication process responsible for fundamentally improving Silicon X-ray microcalorimeter arrays
    Brekosky, RP
    Allen, CA
    Galeazzi, M
    Gygax, JD
    Isenburg, H
    Kelley, RL
    McCammon, D
    McClanahan, RA
    Porter, FS
    Stahle, CK
    Szymkowiak, AE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 439 - 442
  • [32] Fabrication of x-ray absorption gratings via deep x-ray lithography using a conventional x-ray tube
    Pinzek, Simon
    Beckenbach, Thomas
    Viermetz, Manuel
    Meyer, Pascal
    Gustschin, Alex
    Andrejewski, Jana
    Gustschin, Nikolai
    Herzen, Julia
    Schulz, Joachim
    Pfeiffer, Franz
    JOURNAL OF MICRO-NANOPATTERNING MATERIALS AND METROLOGY-JM3, 2021, 20 (04):
  • [33] TO X-RAY OR NOT TO X-RAY - THAT IS THE QUESTION
    BEDRICK, AD
    CLINICAL PEDIATRICS, 1993, 32 (09) : 520 - 520
  • [34] Fabrication of X-ray Masks on a Thick Substrate for Deep X-ray Lithography
    Petrova, E. V.
    Gol'denberg, B. G.
    Kondrat'ev, V. I.
    Mezentseva, L. A.
    Pindyurin, V. F.
    Gentselev, A. N.
    Eliseev, V. S.
    Lyakh, V. V.
    JOURNAL OF SURFACE INVESTIGATION-X-RAY SYNCHROTRON AND NEUTRON TECHNIQUES, 2007, 1 (03) : 307 - 311
  • [35] Fabrication of X-ray mirror for hard X-ray diffraction limited nanofocusing
    Yumoto, Hirokatsu
    Mimura, Hidekazu
    Matsuyama, Satoshi
    Handa, Soichiro
    Shibatani, Akihiko
    Katagishi, Keiko
    Yamamura, Kazuya
    Sano, Yasuhisa
    Endo, Katsuyoshi
    Mori, Yuzo
    Yabashi, Makina
    Nishino, Yoshinori
    Tamasaku, Kenji
    Ishikawa, Tetsuya
    Yamauchi, Kazuto
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 967 - +
  • [36] Fabrication of refractive X-ray focusing lenses by deep X-ray lithography
    Pérennès, F
    Matteucci, M
    Jark, W
    Marmiroli, B
    MICROELECTRONIC ENGINEERING, 2005, 78-79 : 79 - 87
  • [37] Fabrication of x-ray masks on a thick substrate for deep x-ray lithography
    E. V. Petrova
    B. G. Gol’denberg
    V. I. Kondrat’ev
    L. A. Mezentseva
    V. F. Pindyurin
    A. N. Gentselev
    V. S. Eliseev
    V. V. Lyakh
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2007, 1 : 307 - 311
  • [38] Thermal Impact of Cosmic Ray Interaction with an X-Ray Microcalorimeter Array
    Miniussi, Antoine R.
    Adams, Joseph S.
    Bandler, Simon R.
    Beaumont, Sophie
    Chang, Meng P.
    Chervenak, James A.
    Finkbeiner, Fred M.
    Ha, Jong Y.
    Hummatov, Ruslan
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, Frederick S.
    Sadleir, John E.
    Sakai, Kazuhiro
    Smith, Stephen J.
    Wakeham, Nicholas A.
    Wassell, Edward J.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 199 (1-2) : 45 - 55
  • [39] Thermal Impact of Cosmic Ray Interaction with an X-Ray Microcalorimeter Array
    Antoine R. Miniussi
    Joseph S. Adams
    Simon R. Bandler
    Sophie Beaumont
    Meng P. Chang
    James A. Chervenak
    Fred M. Finkbeiner
    Jong Y. Ha
    Ruslan Hummatov
    Richard L. Kelley
    Caroline A. Kilbourne
    Frederick S. Porter
    John E. Sadleir
    Kazuhiro Sakai
    Stephen J. Smith
    Nicholas A. Wakeham
    Edward J. Wassell
    Journal of Low Temperature Physics, 2020, 199 : 45 - 55
  • [40] Prototype of the multi-plxel x-ray microcalorimeter
    Kudo, H
    Nakamura, T
    Arakawa, T
    Ohtsuka, S
    Izumi, T
    Shoji, S
    Sato, H
    Kobayashi, H
    Mori, K
    Homma, T
    Osaka, T
    Mitsuda, K
    Yamasaki, NY
    Fujimoto, R
    Iyomoto, N
    Oshima, T
    Futamoto, K
    Takei, Y
    Ichitsubo, T
    Fujimori, T
    Ishisaki, Y
    Morita, U
    Koga, T
    Sato, K
    Ohashi, T
    Kuroda, Y
    Onishi, M
    Otake, K
    BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1108 - 1111