Fabrication of an X-ray microcalorimeter with an electrodeposited X-ray microabsorber

被引:0
|
作者
Kudo, H [1 ]
Sato, H [1 ]
Nakamura, T [1 ]
Arakawa, T [1 ]
Goto, E [1 ]
Shoji, S [1 ]
Homma, T [1 ]
Osaka, T [1 ]
Mitsuda, K [1 ]
Fujimoto, R [1 ]
Iyomoto, N [1 ]
Audley, MD [1 ]
Miyazaki, T [1 ]
Oshima, T [1 ]
Yamazaki, M [1 ]
Futamoto, K [1 ]
Takei, Y [1 ]
Ishisaki, Y [1 ]
Kagei, T [1 ]
Hiroike, T [1 ]
Ohashi, T [1 ]
Yamasaki, NY [1 ]
Kushino, A [1 ]
Kuroda, Y [1 ]
Onishi, M [1 ]
Goto, M [1 ]
机构
[1] Waseda Univ, Shinjuku Ku, Tokyo 16985555, Japan
来源
LOW TEMPERATURE DETECTORS | 2002年 / 605卷
关键词
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
For the next generation of astronomical X-ray imaging detectors, arrays with large numbers of microstructures (similar to1000 pixels) will be required. To meet this requirement, a tin absorber for an X-ray microcalorimeter, which has a so-called "mushroom" shape, is fabricated by electrodeposition and polishing. This method enables the fabrication of a large number of arrayed microcalorimeters. Details of the fabrication process, the characteristics of the absorber and the fabricated microcalorimeters are reported.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 50 条
  • [1] Sn electrodeposition process for fabricating microabsorber arrays for an X-ray microcalorimeter
    Homma, T
    Sato, H
    Kobayashi, H
    Arakawa, T
    Kudo, H
    Osaka, T
    Shoji, S
    Ishisaki, Y
    Oshima, T
    Iyomoto, N
    Fujimoto, R
    Mitsuda, K
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 559 : 143 - 148
  • [2] The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory
    Kelley, R. L.
    Bandler, S. R.
    Doriese, W. B.
    Ezoe, Y.
    Fujimoto, R.
    Gottardi, L.
    den Hartog, R.
    den Herder, J-W
    Hoevers, H.
    Irwin, K.
    Ishisaki, Y.
    Kilbourne, C. A.
    de Korte, P.
    van der Kuur, J.
    Mitsuda, K.
    Ohashi, T.
    Piro, L.
    Porter, F. S.
    Sato, K.
    Shinozaki, K.
    Shirron, P.
    Smith, S. J.
    Takei, Y.
    Whitehouse, P.
    Yamasaki, N. Y.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 757 - +
  • [3] A Study of X-Ray Response of the TES X-Ray Microcalorimeter for STEM
    Muramatsu, Haruka
    Hayashi, Tasuku
    Maehisa, Keisei
    Nakashima, Yuki
    Mitsuda, Kazuhisa
    Yamasaki, Noriko Y.
    Hara, Toru
    Maehata, Keisuke
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [4] Prototype of the high sensitive X-ray microcalorimeter for X-ray imaging
    Kudo, H
    Nakamura, T
    Arakawa, T
    Ohtsuka, S
    Izumi, T
    Shoji, S
    Sato, H
    Kobayashi, H
    Mori, K
    Homma, T
    Osaka, T
    Mitsuda, K
    Yamasaki, NY
    Fujimoto, R
    Iyomoto, N
    Oshima, T
    Futamoto, K
    Takei, Y
    Ichitsubo, T
    Fujimori, T
    Ishisaki, Y
    Morita, U
    Koga, T
    Sato, K
    Ohashi, T
    Kuroda, Y
    Onishi, M
    Otake, K
    Beppu, F
    SENSORS AND ACTUATORS A-PHYSICAL, 2004, 114 (2-3) : 171 - 175
  • [5] The present and future of microcalorimeter X-ray detectors for fundamental X-ray parameters
    Jach, Terrence
    Thurgate, Stephen
    Beckhoff, Burkhard
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [6] The microcalorimeter X-ray detector: A true paradigm shift in X-ray spectroscopy
    Jach, T.
    Ullom, J. N.
    Elam, W. T.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2009, 169 : 237 - 242
  • [7] The microcalorimeter X-ray detector: A true paradigm shift in X-ray spectroscopy
    T. Jach
    J. N. Ullom
    W. T. Elam
    The European Physical Journal Special Topics, 2009, 169 : 237 - 242
  • [8] High sensitive X-ray microcalorimeter using Bi-Au microabsorber for imaging applications
    Kudo, H. (Kudou.Hiroyuki@iri.metro.tokyo.jp), 1600, Japan Society of Applied Physics (43):
  • [9] High sensitive X-ray microcalorimeter using Bi-Au microabsorber for imaging applications
    Kudo, H
    Arakawa, T
    Ohtsuka, S
    Izumi, T
    Shoji, S
    Sato, H
    Kobayashi, H
    Mori, K
    Homma, T
    Osaka, T
    Iyomoto, N
    Fujimoto, R
    Mitsuda, K
    Yamasaki, NY
    Oshima, T
    Futamoto, K
    Takei, Y
    Ichitsubo, T
    Fujimori, T
    Ishisaki, Y
    Morita, U
    Koga, T
    Shinozaki, K
    Sato, K
    Ohashi, T
    Kuroda, Y
    Onishi, M
    Otake, K
    Beppu, F
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (03): : 1190 - 1195
  • [10] Development of Dielectric X-Ray Microcalorimeter
    Sekiya, N.
    Yamasaki, N. Y.
    Mitsuda, K.
    Kawasaki, S.
    Takei, Y.
    Yoshitake, H.
    Sakai, K.
    Sato, K.
    Maehata, K.
    Takashima, H.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (3-4) : 435 - 441