Modifications to mobile chest radiography technique during the COVID-19 pandemic - implications of X-raying through side room windows

被引:9
作者
England, A. [1 ]
Littler, E. [2 ]
Romani, S. [3 ]
Cosson, P. [4 ]
机构
[1] Keele Univ, Sch Allied Hlth Profess, Mackay Bldg, Keele, Staffs, England
[2] Warrington & Halton Teaching Hosp NHS Fdn Trust, Dept Radiol, Warrington, Cheshire, England
[3] LPD Lab Serv, Blackburn, Lancs, England
[4] Teesside Univ, Med Imaging Dept, Middlesbrough, Cleveland, England
关键词
COVID-19; Mobile radiography; Modified technique; Image quality; Radiation dose; IMAGE QUALITY; TRANSMISSION;
D O I
10.1016/j.radi.2020.07.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Modifications to common radiographic techniques have resulted from the challenges presented by the COVID-19 pandemic. Reports exist regarding the potential benefits of undertaking mobile radiography through side room windows. The aim of this study was to evaluate the impact on image quality and exposure factors when undertaking such examinations. Methods: A phantom based study was undertaken using a digital X-ray room. Control acquisitions, using a commercially available image quality test tool, were performed using standard mobile chest radiography acquisition factors. Image quality (physical and visual), incidence surface air kerma (ISAK), Exposure Index (EI) and Deviation Index (DI) were recorded. Image quality and radiation dose were further assessed for two additional (experimental) scenarios, where a side room window was located immediately adjacent to the exit port of the light beam diaphragm. The goal of experimental scenario one was to modify exposure factors to maintain the control ISAK. The goal of experimental scenario two was to modify exposure factors to maintain the control EI and DI. Dose and image quality data were compared between the three scenarios. Results: To maintain the pre-window (control) ISAK (76 mu Gy), tube output needed a three-fold increase (90 kV/4 mAs versus 90 kV/11.25 mAs). To maintain El/DI a more modest increase in tube output was required (90 kV/8 mAs/ISAK 54 mu Gy). Physical and visual assessments of spatial resolution and signal-to-noise ratio were indifferent between the three scenarios. There was a slight statistically significant reduction in contrast-to-noise ratio when imaging through the glass window (2.3 versus 1.4 and 1.2; P = 0.005). Conclusion: Undertaking mobile X-ray examinations through side room windows is potentially feasible but does require an increase in tube output and is likely to be limited by minor reductions in image quality. Implications for practice: Mobile examinations performed through side room windows should only be used in limited circumstances and future clinical evaluation of this technique is warranted. (C) 2020 Published by Elsevier Ltd on behalf of The College of Radiographers.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 32 条
[1]   Association between subjective evaluation and physical parameters for radiographic images optimization [J].
Alves, A. F. F. ;
Alvarez, M. ;
Ribeiro, S. M. ;
Duarte, S. B. ;
Miranda, J. R. A. ;
Pina, D. R. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01) :123-132
[2]  
[Anonymous], 2005, REC STAND ROUT PERF
[3]   Radiographic Imaging for Patients With Contagious Infectious Diseases: How to Acquire Chest Radiographs of Patients Infected With the Ebola Virus [J].
Auffermann, William F. ;
Kraft, Colleen S. ;
Vanairsdale, Sharon ;
Lyon, G. Marshall, III ;
Tridandapani, Srini .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) :44-48
[4]  
Bontrager K.L., 2005, TXB RADIOGRAPHIC POS, V6th
[5]   The COVID-19 (Coronavirus) pandemic: consequences for occupational health [J].
Burdorf, Alex ;
Porru, Fabio ;
Rugulies, Reiner .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 2020, 46 (03) :229-230
[6]  
Carestream, 2020, DRX REV MOB XRAY SYS
[7]   False negative chest X-Rays in patients affected by COVID-19 pneumonia and corresponding chest CT findings [J].
Cellina, M. ;
Orsi, M. ;
Toluian, T. ;
Pittino, C. Valenti ;
Oliva, G. .
RADIOGRAPHY, 2020, 26 (03) :E189-E194
[8]  
Electronics S, 2013, SAMSUNG XGEO GC80 SA
[9]   Optimizing Image Quality and Dose for Digital Radiography of Distal Pediatric Extremities Using the Contrast-to-Noise Ratio [J].
Hess, R. ;
Neitzel, U. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (07) :643-649
[10]  
Horby P, 2021, NEW ENGL J MED, V384, P693, DOI [10.1056/NEJMoa2021436, 10.1056/NEJMoa2022926]