Identification and Management of Pump Thrombus in the HeartWare Left Ventricular Assist Device System A Novel Approach Using Log File Analysis

被引:69
作者
Jorde, Ulrich P. [1 ]
Aaronson, Keith D. [2 ,3 ]
Najjar, Samer S. [4 ]
Pagani, Francis D. [2 ,3 ]
Hayward, Christopher [5 ]
Zimpfer, Daniel [6 ]
Schloeglhofer, Thomas [6 ]
Pham, Duc T. [7 ]
Goldstein, Daniel J. [1 ]
Leadley, Katrin [8 ]
Chow, Ming-Jay [8 ]
Brown, Michael C. [8 ]
Uriel, Nir [9 ]
机构
[1] Montefiore Med Ctr, Albert Einstein Coll Med, Div Cardiol, New York, NY USA
[2] Univ Michigan, Div Cardiovasc Med, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Cardiac Surg, Ann Arbor, MI 48109 USA
[4] MedStar Washington Hosp Ctr, MedStar Heart & Vasc Inst, Washington, DC USA
[5] St Vincents Hosp, Heart Lung Clin, Sydney, NSW 2010, Australia
[6] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Div Cardiac Surg, Dept Surg, Vienna, Austria
[7] Tufts Med Ctr, Heart Failure & Cardiac Transplantat Ctr, Boston, MA USA
[8] HeartWare Inc, Framingham, MA USA
[9] Univ Chicago Med, Dept Cardiol, Chicago, IL USA
关键词
HeartWare ventricular assist device; pump thrombosis; thrombus; tissue plasminogen activator; thrombolytics; CONTINUOUS-FLOW; DIAGNOSIS; TRANSPLANT; BRIDGE;
D O I
10.1016/j.jchf.2015.06.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The study sought to characterize patterns in the HeartWare (HeartWare Inc., Framingham, Massachusetts) ventricular assist device (HVAD) log files associated with successful medical treatment of device thrombosis. BACKGROUND Device thrombosis is a serious adverse event for mechanical circulatory support devices and is often preceded by increased power consumption. Log files of the pump power are easily accessible on the bedside monitor of HVAD patients and may allow early diagnosis of device thrombosis. Furthermore, analysis of the log files may be able to predict the success rate of thrombolysis or the need for pump exchange. METHODS The log files of 15 ADVANCE trial patients (algorithm derivation cohort) with 16 pump thrombus events treated with tissue plasminogen activator (tPA) were assessed for changes in the absolute and rate of increase in power consumption. Successful thrombolysis was defined as a clinical resolution of pump thrombus including normalization of power consumption and improvement in biochemical markers of hemolysis. Significant differences in log file patterns between successful and unsuccessful thrombolysis treatments were verified in 43 patients with 53 pump thrombus events implanted outside of clinical trials (validation cohort). RESULTS The overall success rate of tPA therapy was 57%. Successful treatments had significantly lower measures of percent of expected power (130.9% vs. 196.1%, p = 0.016) and rate of increase in power (0.61 vs. 2.87, p < 0.0001). Medical therapy was successful in 77.7% of the algorithm development cohort and 81.3% of the validation cohort when the rate of power increase and percent of expected power values were < 1.25% and 200%, respectively. CONCLUSIONS Log file parameters can potentially predict the likelihood of successful tPA treatments and if validated prospectively, could substantially alter the approach to thrombus management. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:849 / 856
页数:8
相关论文
共 26 条
[1]   Use of an Intrapericardial, Continuous-Flow, Centrifugal Pump in Patients Awaiting Heart Transplantation [J].
Aaronson, Keith D. ;
Slaughter, Mark S. ;
Miller, Leslie W. ;
McGee, Edwin C. ;
Cotts, William G. ;
Acker, Michael A. ;
Jessup, Mariell L. ;
Gregoric, Igor D. ;
Loyalka, Pranav ;
Frazier, O. H. ;
Jeevanandam, Valluvan ;
Anderson, Allen S. ;
Kormos, Robert L. ;
Teuteberg, Jeffrey J. ;
Levy, Wayne C. ;
Naftel, David C. ;
Bittman, Richard M. ;
Pagani, Francis D. ;
Hathaway, David R. ;
Boyce, Steven W. .
CIRCULATION, 2012, 125 (25) :3191-+
[2]   HeartWare continuous-flow ventricular assist device thrombosis: The Bad Oeynhausen experience [J].
Aissaoui, Nadia ;
Boergermann, Jochen ;
Gummert, Jan ;
Morshuis, Michiel .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (04) :E37-E39
[3]   Recurrent Early Thrombus Formation in HeartMate II Left Ventricular Assist Device [J].
Capoccia, Massimo ;
Bowles, Christopher T. ;
Sabashnikov, Anton ;
Simon, Andre .
JOURNAL OF INVESTIGATIVE MEDICINE HIGH IMPACT CASE REPORTS, 2013, 1 (02)
[4]   HeartWare Controller Logs A Diagnostic Tool and Clinical Management Aid for the HVAD Pump [J].
Chorpenning, Katherine ;
Brown, Michael C. ;
Voskoboynikov, Neil ;
Reyes, Carlos ;
Dierlam, Anne E. ;
Tamez, Daniel .
ASAIO JOURNAL, 2014, 60 (01) :115-118
[5]   Hemolysis: A harbinger of adverse outcome after Left ventricular assist device implant [J].
Cowger, Jennifer A. ;
Romano, Matthew A. ;
Shah, Palak ;
Shah, Neha ;
Mehta, Vivek ;
Haft, Jonathan W. ;
Aaronson, Keith D. ;
Pagani, Francis D. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :35-43
[6]   Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices [J].
Eckman, Peter M. ;
John, Ranjit .
CIRCULATION, 2012, 125 (24) :3038-3047
[7]   Algorithm for the diagnosis and management of suspected pump thrombus [J].
Goldstein, Daniel J. ;
John, Ranjit ;
Salerno, Christopher ;
Silvestry, Scott ;
Moazami, Nader ;
Horstmanshof, Douglas ;
Adamson, Robert ;
Boyle, Andrew ;
Zucker, Mark ;
Rogers, Joseph ;
Russell, Stuart ;
Long, James ;
Pagani, Francis ;
Jorde, Ulrich .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (07) :667-670
[8]   Successful Treatment of Early Thrombosis of HeartWare Left Ventricular Assist Device With Intraventricular Thrombolytics [J].
Kamouh, Abdallah ;
John, Ranjit ;
Eckman, Peter .
ANNALS OF THORACIC SURGERY, 2012, 94 (01) :281-283
[9]   Management of HeartWare left ventricular assist device thrombosis using intracavitary thrombolytics [J].
Kiernan, Michael S. ;
Duc Thinh Pham ;
DeNofrio, David ;
Kapur, Navin K. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (03) :712-714
[10]   Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the Heart Mate II left ventricular assist device [J].
Kirklin, James K. ;
Naftel, David C. ;
Kormos, Robert L. ;
Pagani, Francis D. ;
Myers, Susan L. ;
Stevenson, Lynne W. ;
Acker, Michael. A. ;
Goldstein, Daniel. L. ;
Silvestry, Scott C. ;
Milano, Carmelo A. ;
Baldwin, J. Timothy ;
Pinney, Sean ;
Rame, J. Eduardo ;
Miller, Marissa A. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :12-22