Conventional and advanced exergy analyses of an air-conditioning system in a subway station

被引:7
作者
Yin, Hua [1 ,2 ]
Guo, Huafang [1 ,2 ]
Tang, Zhihua [1 ,2 ]
Yu, Junyan [3 ]
Lu, Haiyang [4 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Renewable Energy, 2 Nengyuan Rd, Guangzhou 510640, Guangdong, Peoples R China
[2] Guangdong Key Lab New & Renewable Energy Res & De, 2 Nengyuan Rd, Guangzhou 510640, Guangdong, Peoples R China
[3] Guangzhou Metro Grp Co Ltd, Tower A,Wansheng Sq,1238 Xingang East Rd, Guangzhou 510330, Guangdong, Peoples R China
[4] Guangdong Univ Technol, Sch Automated Inst, Waihuan West Rd, Guangzhou 5100006, Guangdong, Peoples R China
关键词
conventional and advanced exergy analyses; air-conditioning system; subway station; CARBON-DIOXIDE; ENERGY; DESTRUCTIONS; OPTIMIZATION; PLANT; CYCLE; HVAC;
D O I
10.1504/IJEX.2019.100365
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning systems in subway stations consume a large amount of energy. In this study, conventional and advanced exergy analyses were carried out to determine the energy-saving potential of an air-conditioning system in a subway station. Results show that air handling unit (AHU) should be improved for the highest values of relative irreversibility (RI) with conventional exergy analysis, whereas the compressor should have the highest improvement priority for the largest avoidable exergy destruction with advanced exergy analysis. Moreover, influences of compressor efficiency, condensation temperature, and evaporation temperature on avoidable exergy destruction of the air-conditioning system were also investigated. According to the findings, compressor efficiency significantly influences the system's total avoidable exergy destruction. The lower the compressor efficiency, the more rapidly the avoidable exergy destruction of the compressor increases. Furthermore, the avoidable exergy destruction of condenser, compressor, cooling tower (CT), and cooling water pump (CWP) increases with the rise of the condensation temperature, whereas that of the evaporator, throttling valve (TV), condenser, compressor, CT, and CWP decreases with the rise of the evaporation temperature.
引用
收藏
页码:236 / 262
页数:27
相关论文
共 50 条
  • [41] Experimental data for an air-conditioning system identification
    Ramirez, Hermes
    Jimenez-Cabas, Javier
    Bula, Antonio
    DATA IN BRIEF, 2019, 25
  • [42] SOLAR AIR-CONDITIONING SYSTEM AT THE UNIVERSITY OF INDONESIA
    Yabase, Hajime
    Saito, Kiyoshi
    Lubis, Arnas
    Alhamid, Idrus
    Nasruddin
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2016, 7 (02) : 212 - 218
  • [43] Study of the Optimal Control of the Central Air Conditioning Cooling Water System for a Deep Subway Station in Chongqing
    Shu, Xingyu
    Dong, Yu
    Liu, Jun
    Xu, Xinhua
    BUILDINGS, 2025, 15 (01)
  • [44] Exergy analysis of hybrid air-conditioning systems with different evaporative-cooling condensers under hot-humid climates
    Yang, Yang
    Yang, Boyu
    Zeng, Jun
    Yin, Linmao
    Xie, Zhiyi
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [45] An Investigation on Energy Consumption of Air Conditioning System in Beijing Subway Stations
    Pan, Song
    Wang, Hongwei
    Pei, Fei
    Yang, Le
    Zhang, Xingxing
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 2568 - 2573
  • [46] Conventional and advanced exergy analyses of a marine steam power plant
    Koroglu, Turgay
    Sogut, Oguz Salim
    ENERGY, 2018, 163 : 392 - 403
  • [47] A thermal comfort field study on subway passengers during air-conditioning season in Beijing
    Pan, Song
    Liu, Yiqiao
    Xie, Lang
    Wang, Xinru
    Yuan, Yanping
    Jia, Xiaoyu
    SUSTAINABLE CITIES AND SOCIETY, 2020, 61
  • [48] Seasonal performance evaluation of refrigeration equipment used for subway train air-conditioning systems
    Liu, Xin
    Zhou, Yuanlong
    Bi, Haiquan
    Lin, Congyun
    Li, Ce
    APPLIED THERMAL ENGINEERING, 2025, 262
  • [49] Analyses and optimizations of thermodynamic performance of an air conditioning system for room heating
    Cheng, XueTao
    Liang, XinGang
    ENERGY AND BUILDINGS, 2013, 67 : 387 - 391
  • [50] Advanced exergy and exergo-economic analyses of an advanced adiabatic compressed air energy storage system
    Guleryuz, Esra Hancer
    Ozen, Dilek Nur
    JOURNAL OF ENERGY STORAGE, 2022, 55