Conventional and advanced exergy analyses of an air-conditioning system in a subway station

被引:7
作者
Yin, Hua [1 ,2 ]
Guo, Huafang [1 ,2 ]
Tang, Zhihua [1 ,2 ]
Yu, Junyan [3 ]
Lu, Haiyang [4 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Renewable Energy, 2 Nengyuan Rd, Guangzhou 510640, Guangdong, Peoples R China
[2] Guangdong Key Lab New & Renewable Energy Res & De, 2 Nengyuan Rd, Guangzhou 510640, Guangdong, Peoples R China
[3] Guangzhou Metro Grp Co Ltd, Tower A,Wansheng Sq,1238 Xingang East Rd, Guangzhou 510330, Guangdong, Peoples R China
[4] Guangdong Univ Technol, Sch Automated Inst, Waihuan West Rd, Guangzhou 5100006, Guangdong, Peoples R China
关键词
conventional and advanced exergy analyses; air-conditioning system; subway station; CARBON-DIOXIDE; ENERGY; DESTRUCTIONS; OPTIMIZATION; PLANT; CYCLE; HVAC;
D O I
10.1504/IJEX.2019.100365
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning systems in subway stations consume a large amount of energy. In this study, conventional and advanced exergy analyses were carried out to determine the energy-saving potential of an air-conditioning system in a subway station. Results show that air handling unit (AHU) should be improved for the highest values of relative irreversibility (RI) with conventional exergy analysis, whereas the compressor should have the highest improvement priority for the largest avoidable exergy destruction with advanced exergy analysis. Moreover, influences of compressor efficiency, condensation temperature, and evaporation temperature on avoidable exergy destruction of the air-conditioning system were also investigated. According to the findings, compressor efficiency significantly influences the system's total avoidable exergy destruction. The lower the compressor efficiency, the more rapidly the avoidable exergy destruction of the compressor increases. Furthermore, the avoidable exergy destruction of condenser, compressor, cooling tower (CT), and cooling water pump (CWP) increases with the rise of the condensation temperature, whereas that of the evaporator, throttling valve (TV), condenser, compressor, CT, and CWP decreases with the rise of the evaporation temperature.
引用
收藏
页码:236 / 262
页数:27
相关论文
共 50 条
  • [31] CGPC: An application to an air-conditioning system
    Petrault, C
    Mehdi, D
    Trigeassou, JC
    PROCEEDINGS OF THE 1997 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 1997, : 1951 - 1952
  • [32] Advanced exergy analysis of an air conditioning system incorporating thermal energy storage
    Mosaffa, A. H.
    Farshi, L. Garousi
    Ferreira, C. A. Infante
    Rosen, M. A.
    ENERGY, 2014, 77 : 945 - 952
  • [33] Asbestos exposure among Seoul metropolitan subway workers during renovation of subway air-conditioning systems
    Yu, IJ
    Yoo, CY
    Chung, YH
    Han, JH
    Yhang, SY
    Yu, GM
    Song, KS
    ENVIRONMENT INTERNATIONAL, 2004, 29 (07) : 931 - 934
  • [34] The Calculation Method of Energy Consumption of Air-Conditioning System in Subway Vehicle Based on Representative Operating Points
    Li, Ce
    Wang, Honglin
    Bi, Haiquan
    6TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND CIVIL ENGINEERING, 2020, 455
  • [35] Analysis of energy-saving for ventilation and air-conditioning system of subway stations with platform screen doors
    Su, Ziyi
    Li, Xiaofeng
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [36] Energy and exergy performance analysis of a marine rotary desiccant air-conditioning system based on orthogonal experiment
    Zhu, Jun
    Chen, Wu
    ENERGY, 2014, 77 : 953 - 962
  • [37] Exergy Analysis of a Heating Ventilation and Air Conditioning (HVAC) System
    Prakash, K.
    Islam, F. R.
    Mamun, K. A.
    Sharma, A.
    Sen, A.
    2018 IEEE 7TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2018, : 378 - 383
  • [38] Integration of Municipal Air-Conditioning, Power, and Gas Supplies Using an LNG Cold Exergy-Assisted Kalina Cycle System
    Ayou, Dereje S.
    Eveloy, Valerie
    ENERGIES, 2020, 13 (18)
  • [39] ENERGY ANALYSIS FOR LIGHTING AND AIR-CONDITIONING SYSTEM OF AN ACADEMIC BUILDING
    Tuan, Tee Boon
    Yahaya, Ahmad Zubair
    Breesam, Younus Fahad
    Dan, Reduan Mat
    Zakaria, Muhammad Zulfattah
    JURNAL TEKNOLOGI, 2015, 76 (05): : 53 - 56
  • [40] Smart and Energy Efficient Air-Conditioning System
    Refaat, Shady S.
    Abu-Rub, Haitham
    Mohamed, Amira
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,