Improved accuracy and precision of bioprinting through progressive cavity pump-controlled extrusion

被引:33
|
作者
Fisch, Philipp [1 ]
Holub, Martin [1 ,2 ]
Zenobi-Wong, Marcy [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Zurich, Switzerland
[2] Delft Univ Technol, Dept Bionanosci, Delft, Netherlands
基金
瑞士国家科学基金会;
关键词
bioprinting; progressive cavity pump; pneumatic extrusion; alginate; gelatin; gellan gum; micro-extrusion bioprinting; CELL; BIOINKS;
D O I
10.1088/1758-5090/abc39b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D bioprinting has seen a tremendous growth in recent years in a variety of fields such as tissue engineering, drug testing and regenerative medicine, which has led researchers and manufacturers to continuously advance and develop novel bioprinting techniques and materials. Although new bioprinting methods are emerging (e.g. contactless and volumetric bioprinting), micro-extrusion bioprinting remains the most widely used method. Micro-extrusion bioprinting, however, is still largely dependent on the conventional pneumatic extrusion process, which relies heavily on homogenous biomaterial inks and bioinks to maintain a constant material flow rate. Augmenting the functionality of the bioink with the addition of nanoparticles, cells or biopolymers can induce inhomogeneities resulting in uneven material flow during printing and/or clogging of the nozzle, leading to defects in the printed construct. In this work, we evaluated a novel extrusion technique based on a miniaturized progressive cavity pump (PCP) which allows precise control over the volumetric flow rate by positive displacement. We compared the accuracy and precision of this system to the pneumatic extrusion system and tested both systems for their effect on cell viability after extrusion. The PCP achieved a significantly higher accuracy and precision compared to the pneumatic system, while maintaining good viability. These improvements were independent of the bioink composition, printing speed or nozzle size. This study demonstrates the merit of precise extrusion-process control in bioprinting by PCPs and investigates their influence on process-induced cell damage. PCPs are a promising tool for bioprinting and could help provide standardized and validated bioprinted constructs while leaving the researcher more freedom in the design of the bioinks.
引用
收藏
页数:18
相关论文
共 6 条
  • [1] Conceptual design and development of a progressive cavity pump for extrusion-based additive manufacturing applications
    Ugurluoglu, Yusuf Furkan
    Ferreira, Ana Marina
    Gentile, Piergiorgio
    Munguia, Javier
    CIRP JOURNAL OF MANUFACTURING SCIENCE AND TECHNOLOGY, 2023, 46 : 191 - 203
  • [2] Pump-controlled RGB single-mode polymer lasers based on a hybrid 2D-3D μ-cavity for temperature sensing
    Ge, Kun
    Guo, Dan
    Niu, Ben
    Xu, Zhiyang
    Ruan, Jun
    Zhai, Tianrui
    NANOPHOTONICS, 2021, 10 (18) : 4591 - 4599
  • [3] Dual feed progressive cavity pump extrusion system for functionally graded direct ink write 3D printing
    Sevcik, Max J.
    Golson, Jacob
    Bjerke, Gabriel
    Snyder, Isaac
    Taylor, Gage
    Wilson, Finnegan
    Rabinowitz, Grace I.
    Kline, Dylan J.
    Grapes, Michael D.
    Sullivan, Kyle T.
    Belof, Jonathan L.
    Eliasson, Veronica
    HARDWAREX, 2024, 17
  • [4] IMPROVED INTER-OBSERVER VARIABILITY, ACCURACY AND PRECISION OF ECHOCARDIOGRAPHIC VISUAL LVEF ASSESSMENT THROUGH A SELF-DIRECTED LEARNING PROGRAM USING CMR IMAGES
    Thavendiranathan, Paaladinesh
    Popovic, Zoran
    Flamm, Scott
    Dahiya, Arun
    Grimm, Richard
    Marwick, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1313 - E1313
  • [5] Improved precision and accuracy for high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometric exact mass measurement of small molecules from the simultaneous and controlled introduction of internal calibrants via a second electrospray nebuliser
    Herniman, JM
    Bristow, TWT
    O'Connor, G
    Jarvis, J
    Langley, GJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (24) : 3035 - 3040
  • [6] Heat capacity of the reference material synthetic sapphire (alpha-Al2O3) at temperatures from 298.15 K to 1000 K by adiabatic calorimetry. Increased accuracy and precision through improved instrumentation and computer control
    Stolen, S
    Glockner, R
    Gronvold, F
    JOURNAL OF CHEMICAL THERMODYNAMICS, 1996, 28 (11): : 1263 - 1281