Quality evaluation of stator coils and bars under thennal cycling stress

被引:9
作者
Zhu, H. [1 ]
Morton, C. [1 ,2 ]
机构
[1] Powertech Labs, Surrey, BC, Canada
[2] BC Hydro & Power Author, Vancouver, BC, Canada
来源
CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION | 2006年
关键词
D O I
10.1109/ELINSL.2006.1665338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents our recent experience in quality evaluation of stator coils and bars during thermal cycling (TC) tests using several diagnostic tools. Diagnostic tests, such as tap tests, dissipation factor tests, partial discharge tests, and capacitance measurements were conducted to evaluate the insulation condition during and after thermal cycling testing. Thermal cycling tests accompanied with the diagnostic tests can help to identify defects in the quality and performance of coils/bars. Bars/coils which can pass a VE test may have severe delamination and defects during a TC test. Since there are no pass/fail criteria for TC testing in the current IEEE Std 1310-1996, voltage endurance (VE) testing following TC testing has been proposed as an alternative pass/fail criterion for quality evaluation of stator coils/bars.
引用
收藏
页码:384 / +
页数:2
相关论文
共 7 条
[1]   Multi-stress aging of stator bars with electrical, thermal, and mechanical stresses as simultaneous acceleration factors [J].
Bartnikas, R ;
Morin, R .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) :702-714
[2]  
HALLDORSON G, 2004, 2004 IRIS ROT MACH C
[3]  
Stone G., 2004, Electrical Insulation for Rotating Machines-Design Evaluation Aging Testing and Repair
[4]  
STONE GC, 1991, IEEE EN CONV, V6
[5]  
ZHU H, 2004, 2004 HYDR C MONTR CA
[6]  
13101996 IEEE
[7]  
15532002 IEEE