Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Sorensen, Erik N. [1 ]
Kon, Zachary N.
Feller, Erika D.
Pham, Si M.
Griffith, Bartley P.
机构
[1] Univ Maryland, Med Ctr, Dept Clin Engn, 22 S Greene St,Rm PTH06, Baltimore, MD 21201 USA
关键词
PUMP; THROMBOSIS; IMPLANTATION; OPTIMIZATION; MIGRATION; SUPPORT; CANNULA;
D O I
10.1016/j.athoracsur.2017.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We previously investigated preoperative variables associated with qualitative inflow cannula malposition in the HeartMate II (Thoratec-Abbott, Abbott Park, IL) continuous-flow left ventricular assist device. In this report, we assess inflow cannula malposition quantitatively in recipients of both the HeartMate II and the HeartWare (Medtronic-HeartWare, Minneapolis, MN) and examine its association with device thrombosis. Methods. Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. Ideal position lies on a line from the apex to the center of the mitral valve. Positive anterior plane angulation indicates deviation toward the superior free wall; negative, toward the inferior wall. Positive lateral plane angulation indicates deviation toward the septum; negative, toward the lateral wall. Device thrombosis was assessed based on clinical criteria. Results. Fifty-four HeartMate II patients and 68 HeartWare patients were analyzed. Inflow cannula deviation was significantly higher for HeartMate II than for HeartWare (anterior plane angle 36.7 +/- 16.8 versus -18.7 +/- 11.6 degrees, p < 0.001; lateral plane angle 23.7 +/- 20.1 versus 0.2 +/- 15.0 degrees, p < 0.001. Pump thrombosis occurred in 31% of HeartMate II patients and 2.9% of HeartWare patients (p < 0.001). In a multivariate model, HeartMate II and increasing inflow cannula deviation toward the septum were associated with higher thrombosis risk (odds ratio 1.35 per 10-degree increase). Conclusions. We found distinct device-dependent differences in inflow cannula positioning and thrombosis, with HeartWare showing both less malposition and less thrombosis. Malposition toward the ventricular septum may contribute to pump thrombosis through a vicious cycle of suction events, low flow, and speed reduction. (C) 2018 by The Society of Thoracic Surgeons.
引用
收藏
页码:1377 / 1383
页数:7
相关论文
共 50 条
  • [31] CT Imaging of Complications Associated with Continuous-Flow Left Ventricular Assist Devices (LVADs)
    Shroff, Girish S.
    Ocazionez, Daniel
    Akkanti, Bindu
    Vargas, Daniel
    Garza, Alheli
    Gupta, Pushpender
    Patel, Jayeshkumar A.
    Patel, Manish K.
    Gregoric, Igor D.
    SEMINARS IN ULTRASOUND CT AND MRI, 2017, 38 (06) : 616 - 628
  • [32] Thrombosis in Continuous-Flow Left Ventricular Assist Devices: Pathophysiology, Prevention, and Pharmacologic Management
    Jennings, Douglas L.
    Weeks, Phillip A.
    PHARMACOTHERAPY, 2015, 35 (01): : 79 - 98
  • [33] Aortic root thrombosis in patients supported with continuous-flow left ventricular assist devices
    Fried, Justin
    Garan, Arthur R.
    Shames, Sophia
    Masoumi, Amirali
    Yuzefpolskaya, Melana
    Takeda, Koji
    Takayama, Hiroo
    Uriel, Nir
    Naka, Yoshifumi
    Colombo, Paolo C.
    Topkara, Veli K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (12) : 1425 - 1432
  • [34] Pharmacotherapeutic Management of Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices
    Sieg, Adam C.
    Moretz, Jeremy D.
    Horn, Edward
    Jennings, Douglas L.
    PHARMACOTHERAPY, 2017, 37 (11): : 1432 - 1448
  • [35] Impact of time off anticoagulation in patients with continuous-flow left ventricular assist devices
    Christian A. Inchaustegui
    Ashley Patel
    Harveen K. Lamba
    Andrew Brown
    Justin Arunthamakun
    Kevin Ting
    Subhasis Chatterjee
    Ajith P. Nair
    Joggy K. George
    Alexis E. Shafii
    Kenneth K. Liao
    Andrew B. Civitello
    Journal of Artificial Organs, 2023, 26 : 275 - 286
  • [36] Concomitant repair for mild aortic insufficiency and continuous-flow left ventricular assist devices
    Fukuhara, Shinichi
    Ikegami, Hirohisa
    Polanco, Antonio R.
    Song, Jeremy J.
    Han, Jiho
    Takeda, Koji
    Kurlansky, Paul A.
    Takayama, Hiroo
    Naka, Yoshifumi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (06) : 1062 - 1068
  • [37] Risk of pump thrombosis and stroke in patients with continuous-flow left ventricular assist devices and gastrointestinal bleeding
    Szymanski, Thomas W.
    Weeks, Phillip A.
    Patel, Chandni J.
    Jezovnik, Mateja K.
    Gulbis, Brian
    Nathan, Sriram S.
    Jumean, Marwan F.
    Radovancevic, Rajko
    Kar, Biswajit
    Gregoric, Igor D.
    ARTIFICIAL ORGANS, 2020, 44 (11) : 1171 - 1175
  • [38] Characteristics and outcomes of gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices: A systematic review
    Carlson, Laura A.
    Maynes, Elizabeth J.
    Choi, Jae Hwan
    Hallett, Andrew M.
    Horan, Dylan P.
    Weber, Matthew P.
    Deb, Avijit K.
    Patel, Sinal
    Samuels, Louis E.
    Morris, Rohinton J.
    Entwistle, John W.
    Massey, H. Todd
    Tchantchaleishvili, Vakhtang
    ARTIFICIAL ORGANS, 2020, 44 (11) : 1150 - 1161
  • [39] Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices
    Eckman, Peter M.
    John, Ranjit
    CIRCULATION, 2012, 125 (24) : 3038 - 3047
  • [40] HeartMate® II continuous-flow left ventricular assist system
    Sheikh, Farooq H.
    Russell, Stuart D.
    EXPERT REVIEW OF MEDICAL DEVICES, 2011, 8 (01) : 11 - 21