Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Sorensen, Erik N. [1 ]
Kon, Zachary N.
Feller, Erika D.
Pham, Si M.
Griffith, Bartley P.
机构
[1] Univ Maryland, Med Ctr, Dept Clin Engn, 22 S Greene St,Rm PTH06, Baltimore, MD 21201 USA
关键词
PUMP; THROMBOSIS; IMPLANTATION; OPTIMIZATION; MIGRATION; SUPPORT; CANNULA;
D O I
10.1016/j.athoracsur.2017.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We previously investigated preoperative variables associated with qualitative inflow cannula malposition in the HeartMate II (Thoratec-Abbott, Abbott Park, IL) continuous-flow left ventricular assist device. In this report, we assess inflow cannula malposition quantitatively in recipients of both the HeartMate II and the HeartWare (Medtronic-HeartWare, Minneapolis, MN) and examine its association with device thrombosis. Methods. Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. Ideal position lies on a line from the apex to the center of the mitral valve. Positive anterior plane angulation indicates deviation toward the superior free wall; negative, toward the inferior wall. Positive lateral plane angulation indicates deviation toward the septum; negative, toward the lateral wall. Device thrombosis was assessed based on clinical criteria. Results. Fifty-four HeartMate II patients and 68 HeartWare patients were analyzed. Inflow cannula deviation was significantly higher for HeartMate II than for HeartWare (anterior plane angle 36.7 +/- 16.8 versus -18.7 +/- 11.6 degrees, p < 0.001; lateral plane angle 23.7 +/- 20.1 versus 0.2 +/- 15.0 degrees, p < 0.001. Pump thrombosis occurred in 31% of HeartMate II patients and 2.9% of HeartWare patients (p < 0.001). In a multivariate model, HeartMate II and increasing inflow cannula deviation toward the septum were associated with higher thrombosis risk (odds ratio 1.35 per 10-degree increase). Conclusions. We found distinct device-dependent differences in inflow cannula positioning and thrombosis, with HeartWare showing both less malposition and less thrombosis. Malposition toward the ventricular septum may contribute to pump thrombosis through a vicious cycle of suction events, low flow, and speed reduction. (C) 2018 by The Society of Thoracic Surgeons.
引用
收藏
页码:1377 / 1383
页数:7
相关论文
共 50 条
  • [21] Prosthetic Valve Fate in Patients With Continuous-Flow Left Ventricular Assist Devices
    Kaneyuki, Daisuke
    Patel, Krushang
    Vinogradsky, Alice V.
    Rajesh, Kavya
    Hynds, Melissa A.
    Kurlansky, Paul A.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Sayer, Gabriel T.
    Uriel, Nir
    Naka, Yoshifumi
    Takeda, Koji
    ASAIO JOURNAL, 2025, 71 (05) : 403 - 408
  • [22] Cerebrovascular events in children on intracorporeal continuous-flow left ventricular assist devices
    Sert, Dogan Emre
    Kocabeyoglu, Sinan Sabit
    Kervan, Umit
    Karahan, Mehmet
    Beyazal, Osman Fehmi
    Akdi, Mustafa
    Yilmaz, Abdulkadir
    Catav, Zeki
    ARTIFICIAL ORGANS, 2020, 44 (12) : 1251 - 1258
  • [23] Device thrombosis in HeartMate II continuous-flow Left ventricular assist devices: A multifactorial phenomenon
    Uriel, Nir
    Han, Jason
    Morrison, Kerry A.
    Nahumi, Nadav
    Yuzefpolskaya, Melana
    Garan, Arthur R.
    Duong, Jimmy
    Colombo, Paolo C.
    Takayama, Hiroo
    Thomas, Sunu
    Naka, Yoshifumi
    Jorde, Ulrich P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) : 51 - 59
  • [24] Argatroban administration as therapy for thrombosis in patients with continuous-flow ventricular assist devices
    Wert, Leonhard
    Hanke, Jasmin S.
    Dogan, Guenes
    Ricklefs, Marcel
    Chatterjee, Anamika
    Feldmann, Christina
    Ismail, Issam
    Napp, L. Christian
    Haverich, Axel
    Schmitto, Jan D.
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S1720 - S1727
  • [25] Delayed febrile response with bloodstream infections in patients with continuous-flow left ventricular assist devices
    Wrobel, Christopher A.
    Drazner, Mark H.
    Ayers, Colby R.
    Pham, David D.
    La Hoz, Ricardo M.
    Grodin, Justin L.
    Garg, Sonia
    Mammen, Pradeep P. A.
    Morlend, Robert M.
    Araj, Faris
    Amin, Alpesh A.
    Cornwell, William K.
    Thibodeau, Jennifer T.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2019, 67 (03) : 653 - 658
  • [26] A Comprehensive Imaging Approach to Guide the Management of Patients with Continuous-Flow Left Ventricular Assist Devices
    Hannawi, Bashar
    Estep, Jerry D.
    CARDIOLOGY CLINICS, 2018, 36 (04) : 583 - +
  • [27] Electrophysiologic Changes and Their Effects on Ventricular Arrhythmias in Patients with Continuous-Flow Left Ventricular Assist Devices
    Celik, Mehmet
    Emiroglu, Mehmet Yunus
    Bayram, Zubeyde
    Izci, Servet
    Karagoz, Ali
    Akbal, Ozgur Yasar
    Kahyaoglu, Muzaffer
    Kup, Ayhan
    Yilmaz, Yusuf
    Kirali, Mehmet Kaan
    Ozdemir, Nihal
    ASAIO JOURNAL, 2022, 68 (03) : 341 - 348
  • [28] Echocardiographic assessment of flow across continuous-flow ventricular assist devices at low speeds
    George, Robert S.
    Sabharwal, Nikant K.
    Webb, Carole
    Yacoub, Magdi H.
    Bowles, Christopher T.
    Hedger, Michael
    Khaghani, Asghar
    Birks, Emma J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (11) : 1245 - 1252
  • [29] Gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices: A comprehensive review
    Del Rio-Pertuz, Gaspar
    Nair, Nandini
    ARTIFICIAL ORGANS, 2023, 47 (01) : 12 - 23
  • [30] Outcomes from a recovery protocol for patients with continuous-flow left ventricular assist devices
    Knierim, Jan
    Heck, Roland
    Pieri, Marina
    Schoenrath, Felix
    Soltani, Sajjad
    Stawowy, Philipp
    Dreysse, Stephan
    Stein, Julia
    Mueller, Marcus
    Mulzer, Johanna
    Dandel, Michael
    Falk, Volkmar
    Krabatsch, Thomas
    Potapov, Evgenij
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04) : 440 - 448