Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Sorensen, Erik N. [1 ]
Kon, Zachary N.
Feller, Erika D.
Pham, Si M.
Griffith, Bartley P.
机构
[1] Univ Maryland, Med Ctr, Dept Clin Engn, 22 S Greene St,Rm PTH06, Baltimore, MD 21201 USA
关键词
PUMP; THROMBOSIS; IMPLANTATION; OPTIMIZATION; MIGRATION; SUPPORT; CANNULA;
D O I
10.1016/j.athoracsur.2017.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We previously investigated preoperative variables associated with qualitative inflow cannula malposition in the HeartMate II (Thoratec-Abbott, Abbott Park, IL) continuous-flow left ventricular assist device. In this report, we assess inflow cannula malposition quantitatively in recipients of both the HeartMate II and the HeartWare (Medtronic-HeartWare, Minneapolis, MN) and examine its association with device thrombosis. Methods. Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. Ideal position lies on a line from the apex to the center of the mitral valve. Positive anterior plane angulation indicates deviation toward the superior free wall; negative, toward the inferior wall. Positive lateral plane angulation indicates deviation toward the septum; negative, toward the lateral wall. Device thrombosis was assessed based on clinical criteria. Results. Fifty-four HeartMate II patients and 68 HeartWare patients were analyzed. Inflow cannula deviation was significantly higher for HeartMate II than for HeartWare (anterior plane angle 36.7 +/- 16.8 versus -18.7 +/- 11.6 degrees, p < 0.001; lateral plane angle 23.7 +/- 20.1 versus 0.2 +/- 15.0 degrees, p < 0.001. Pump thrombosis occurred in 31% of HeartMate II patients and 2.9% of HeartWare patients (p < 0.001). In a multivariate model, HeartMate II and increasing inflow cannula deviation toward the septum were associated with higher thrombosis risk (odds ratio 1.35 per 10-degree increase). Conclusions. We found distinct device-dependent differences in inflow cannula positioning and thrombosis, with HeartWare showing both less malposition and less thrombosis. Malposition toward the ventricular septum may contribute to pump thrombosis through a vicious cycle of suction events, low flow, and speed reduction. (C) 2018 by The Society of Thoracic Surgeons.
引用
收藏
页码:1377 / 1383
页数:7
相关论文
共 50 条
  • [1] Transthoracic Echocardiographic Assessment of Continuous-Flow Left Ventricular Assist Devices
    Rasalingam, Ravi
    Johnson, Stephanie N.
    Bilhorn, Kyle R.
    Huang, Pei-Hsiu
    Makan, Majesh
    Moazami, Nader
    Perez, Julio E.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (02) : 135 - 148
  • [2] The Physiology of Continuous-Flow Left Ventricular Assist Devices
    Lim, Hoong Sern
    Howell, Neil
    Ranasinghe, Aaron
    JOURNAL OF CARDIAC FAILURE, 2017, 23 (02) : 169 - 180
  • [3] Hematologic disorders and continuous-flow left ventricular assist devices
    Connors, Jean M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (11) : 1114 - 1116
  • [4] Thrombus formation at the inflow cannula of continuous-flow left ventricular assist devices-A systematic analysis
    Kaufmann, Friedrich
    Hoermandinger, Christoph
    Knosalla, Christoph
    Falk, Volkmar
    Potapov, Evgenij
    ARTIFICIAL ORGANS, 2022, 46 (08) : 1573 - 1584
  • [5] Allograft Rejection in Patients Supported With Continuous-Flow Left Ventricular Assist Devices
    Healy, Aaron H.
    Mason, Nathan O.
    Hammond, M. Elizabeth
    Reid, Bruce B.
    Clayson, Stephen E.
    Drakos, Stavros G.
    Kfoury, Abdallah G.
    Patel, Amit N.
    Bull, David A.
    Budge, Deborah
    Alharethi, Rami A.
    Bader, Feras M.
    Gilbert, Edward M.
    Stehlik, Josef
    Selzman, Craig H.
    ANNALS OF THORACIC SURGERY, 2011, 92 (05) : 1601 - 1607
  • [6] Concomitant mitral repair and continuous-flow left ventricular assist devices: Is it warranted?
    Fukuhara, Shinichi
    Takeda, Koji
    Chiuzan, Codruta
    Han, Jiho
    Kurlansky, Paul A.
    Takayama, Hiroo
    Naka, Yoshifumi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (04) : 1303 - +
  • [7] Continuous-flow left ventricular assist devices induce Left ventricular reverse remodeling
    Jacobs, Steven
    Geens, Jef
    Rega, Filip
    Burkhoff, Daniel
    Meyns, Bart
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04) : 466 - 468
  • [8] Echocardiography and Continuous-Flow Left Ventricular Assist Devices Evidence and Limitations
    Cohen, David G.
    Thomas, James D.
    Freed, Benjamin H.
    Rich, Jonathan D.
    Sauer, Andrew J.
    JACC-HEART FAILURE, 2015, 3 (07) : 554 - 564
  • [9] Cerebrovascular Events After Continuous-Flow Left Ventricular Assist Devices
    Tahsili-Fahadan, Pouya
    Curfman, David R.
    Davis, Albert A.
    Yahyavi-Firouz-Abadi, Noushin
    Rivera-Lara, Lucia
    Nassif, Michael E.
    LaRue, Shane J.
    Ewald, Gregory A.
    Zazulia, Allyson R.
    NEUROCRITICAL CARE, 2018, 29 (02) : 225 - 232
  • [10] Continuous-flow left ventricular assist devices: Management in the emergency department
    Hockstein, Maxwell A.
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2020, 1 (04) : 362 - 370