An analysis of the operation of a flexible oxy-fired CFB power plant integrated with a thermal energy storage system

被引:13
作者
Arias, B. [1 ]
机构
[1] CSIC INCAR, Inst Nacl Carbon, C Francisco Pintado Fe 26, Oviedo 33011, Spain
关键词
Oxy-fired combustion; Energy storage; Flexible power output; CO2; capture; CARBON CAPTURE; AIR SEPARATION; FLEXIBILITY; GENERATION; PEAK; CCS; KEY;
D O I
10.1016/j.ijggc.2015.12.007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work analyzes the performance of an oxy-fired CFB power plant integrated with an energy storage system. The system contains two silos connected to a combustor to allow the power output to be modified while operating at a constant coal firing rate. During low energy demand periods, part of the thermal power released in the combustor is stored as sensible heat in a high temperature silo by feeding in solids from a low temperature silo. The energy stored can then be used during high demand periods to deliver additional power. In order to optimize the generation of power, two steam cycles have been integrated within the system by making use of the different heat exchangers available. While one cycle is operating at base-load in order to respond at least to the power requirements associated to power plant auxiliaries, the other enters into operation only during high demand periods. The effect of the different variables involved in the process has been analyzed. The arrangement proposed in this work is able to modify the power output by a ratio of 5. The system is able to operate for 8 h and deliver a net power output of only 30 MWe. A net power output of 150 MWe can be generated during a period of 4h with a thermal input of 214 MWt by using the energy storage system. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 28 条
[1]  
[Anonymous], 2001, ENERGY SUSTAIN DEV, DOI [10.1016/S0973-0826(08)60285-9, DOI 10.1016/S0973-0826(08)60285-9]
[2]  
[Anonymous], 2012, OPERATING FLEXIBILIT
[3]   Oxy-fired fluidized bed combustors with a flexible power output using circulating solids for thermal energy storage [J].
Arias, B. ;
Criado, Y. A. ;
Sanchez-Biezma, A. ;
Abanades, J. C. .
APPLIED ENERGY, 2014, 132 :127-136
[4]  
Basu P., 2015, CIRCULATING FLUIDIZE
[5]   Initial evaluation of the impact of post-combustion capture of carbon dioxide on supercritical pulverised coal power plant part load performance [J].
Chalmers, Hannah ;
Gibbins, Jon .
FUEL, 2007, 86 (14) :2109-2123
[6]   Valuing flexible operation of power plants with CO2 capture [J].
Chalmers, Hannah ;
Leach, Matt ;
Lucquiaud, Mathieu ;
Gibbins, Jon .
GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01) :4289-4296
[7]   Optimal operation of flexible post-combustion CO2 capture in response to volatile electricity prices [J].
Cohen, Stuart M. ;
Rochelle, Gary T. ;
Webber, Michael E. .
10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 :2604-2611
[8]   Air separation and flue gas compression and purification units for oxy-coal combustion systems [J].
Darde, Arthur ;
Prabhakar, Rajeev ;
Tranier, Jean-Pierre ;
Perrin, Nicolas .
GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01) :527-534
[9]   Flexible CCS plants - A key to near-zero emission electricity systems [J].
Davison, John .
10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 :2548-2555
[10]  
DOE/NEIL, 2007, 20071281 DOENETL, V1