Single and double pass solar air heaters with partially perforated cover and packed mesh

被引:90
作者
Nowzari, Raheleh [1 ]
Aldabbagh, L. B. Y. [2 ]
Egelioglu, F. [1 ]
机构
[1] Eastern Mediterranean Univ, Dept Mech Engn, Famagusta, North Cyprus, Turkey
[2] Univ Mosul, Mechatron Engn Dept, Coll Engn, Mosul, Iraq
关键词
Solar air heater; Perforated cover; Packed bed; Thermal efficiency; WIRE MESH; THERMAL PERFORMANCE; THERMOHYDRAULIC PERFORMANCE; COLLECTOR EFFICIENCY; FINS; FLOW;
D O I
10.1016/j.energy.2014.06.069
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the thermal performance of the single and double pass solar air heaters with normal glazing and with quarter perforated cover was investigated experimentally. The solar air collector was tested with two different perforated covers in which the holes made on one cover had the center-to-center distance of 20D (6 cm) and on the other cover it was 10D (3 cm), where D (0.3 cm) was the hole diameter. The air mass flow rate was varied between 0.011 kg/s and 0.037 kg/s. The efficiency of the double pass was always greater than the single pass air heater by 5-22.7% for the same air mass flow rate. At mass flow rate of 0.037 kg/s, the average efficiency of single and double pass air heaters with normal glazing were 49.98% and 53.67%, respectively. It was found that, the efficiency of the air heater with 10D perforated cover is slightly higher than the one with 20D perforated cover for both single and counter flow collectors. The average efficiency of single and double pass solar air heaters with 10D perforated cover were 46.40% and 54.76%, respectively, at mass flow rate of 0.032 kg/s while at the same mass flow rate, the average efficiency of single and double pass air heaters with normal glazing were 49.36% and 51.70%, respectively. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:694 / 702
页数:9
相关论文
共 32 条
[1]   Single and double pass solar air heaters with wire mesh as packing bed [J].
Aldabbagh, L. B. Y. ;
Egelioglu, F. ;
Ilkan, M. .
ENERGY, 2010, 35 (09) :3783-3787
[2]   An evaluation of heat transfer and effectiveness for unglazed transpired solar air heaters [J].
Collins, Michael R. ;
Abulkhair, Hani .
SOLAR ENERGY, 2014, 99 :231-245
[3]   Performance of unglazed solar ventilation air pre-heaters for broiler barns [J].
Cordeau, Sebastien ;
Barrington, Suzelle .
SOLAR ENERGY, 2011, 85 (07) :1418-1429
[4]   The effect of using transverse fins on a double pass flow solar air heater using wire mesh as an absorber [J].
El-khawajah, M. F. ;
Aldabbagh, L. B. Y. ;
Egelioglu, F. .
SOLAR ENERGY, 2011, 85 (07) :1479-1487
[5]   Year round performance of double pass solar air heater with packed bed [J].
El-Sebaii, A. A. ;
Aboul-Enein, S. ;
Ramadan, M. R. I. ;
El-Bialy, E. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (03) :990-1003
[6]   Investigation of thermal performance of-double pass-flat and v-corrugated plate solar air heaters [J].
El-Sebaii, A. A. ;
Aboul-Enein, S. ;
Ramadan, M. R. I. ;
Shalaby, S. M. ;
Moharram, B. M. .
ENERGY, 2011, 36 (02) :1076-1086
[7]   Effect of selective coating on thermal performance of flat plate solar air heaters [J].
El-Sebaii, A. A. ;
Al-Snani, H. .
ENERGY, 2010, 35 (04) :1820-1828
[8]   Experimental energy and exergy analysis of a double-flow solar air heater having different obstacles on absorber plates [J].
Esen, Hikmet .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1046-1054
[9]  
Holman J.P., 1989, EXPT METHODS ENG, V5th
[10]   Performance investigation of flat plate, v-corrugated and finned air collectors [J].
Karim, MA ;
Hawlader, MNA .