Measurement of the nuclear polarization of hydrogen and deuterium molecules using a Lamb-shift polarimeter

被引:10
作者
Engels, Ralf [1 ]
Gorski, Robert [1 ,4 ]
Grigoryev, Kiril [1 ]
Mikirtychyants, Maxim [1 ,5 ]
Rathmann, Frank [1 ]
Seyfarth, Hellmut [1 ]
Stroeher, Hans [1 ]
Weiss, Philipp [1 ]
Kochenda, Leonid [2 ]
Kravtsov, Peter [2 ]
Trofimov, Viktor [2 ]
Tschernov, Nikolay [2 ]
Vasilyev, Alexander [2 ]
Vznuzdaev, Marat [2 ]
Schieck, Hans Paetz Gen [3 ]
机构
[1] Forschungszentrum Julich, Inst Kernphys, D-52428 Julich, Germany
[2] Petersburg Nucl Phys Inst, Lab Cryogen & Superconduct Tech, Gatchina 188300, Russia
[3] Univ Cologne, Inst Kernphys, D-50937 Cologne, Germany
[4] Univ Aachen, Phys Inst IIIA, Aachen, Germany
[5] Ruhr Univ Bochum, Inst Expt Phys, Bochum, Germany
关键词
SPIN-FILTER POLARIMETER; CROSS-SECTIONS; ION-BEAMS; CS VAPOR; INCIDENT; ATOMS;
D O I
10.1063/1.4897479
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Lamb-shift polarimeters are used to measure the nuclear polarization of protons and deuterons at energies of a few keV. In combination with an ionizer, the polarization of hydrogen and deuterium atoms was determined after taking into account the loss of polarization during the ionization process. The present work shows that the nuclear polarization of hydrogen or deuterium molecules can be measured as well, by ionizing the molecules and injecting the H-2(+) (or D-2(+)) ions into the Lamb-shift polarimeter. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:10
相关论文
共 24 条
[1]   Nuclear polarization of molecular hydrogen recombined on a non-metallic surface [J].
Airapetian, A ;
Akopov, N ;
Akopov, Z ;
Amarian, M ;
Ammosov, VV ;
Andrus, A ;
Aschenauer, EC ;
Augustymak, W ;
Avakian, R ;
Avetissian, A ;
Avetissian, E ;
Bailey, P ;
Baturin, V ;
Baumgarten, C ;
Beckmann, M ;
Belostotski, S ;
Bernreuther, S ;
Bianchi, N ;
Blok, HP ;
Böttcher, H ;
Borissov, A ;
Borysenko, A ;
Bouwhuis, M ;
Brack, J ;
Brüll, A ;
Bryzgalov, V ;
Capitanilo, GP ;
Chiang, HC ;
Ciullo, G ;
Contalbrigo, M ;
Court, G ;
Dalpiaz, PF ;
De Leo, R ;
De Nardo, L ;
De Sanctis, E ;
Devitsin, E ;
Di Nezza, P ;
Düren, M ;
Ehrenfried, M ;
Elalaoui-Moulay, A ;
Elbakian, G ;
Ellinghaus, F ;
Elschenbroich, U ;
Ely, J ;
Fabbri, R ;
Fantoni, A ;
Fechtchenko, A ;
Felawka, L ;
Fox, B ;
Franz, J .
EUROPEAN PHYSICAL JOURNAL D, 2004, 29 (01) :21-26
[2]  
CISNEROS C, 1976, PHYS REV A, V14, P88, DOI 10.1103/PhysRevA.14.88
[3]  
Clegg T. B., 1997, TUNL ANN REPORT, P114
[4]   Background reduction by a getter pump around the ionization volume of a Lamb-shift polarimeter and possible improvements of polarized ion sources [J].
Engels, R ;
Emmerich, R ;
Grigoryev, K ;
Schieck, HP ;
Ley, J ;
Mikirtychyants, M ;
Rathmann, F ;
Sarkadi, J ;
Seyfarth, H ;
Tenckhoff, G ;
Vasilyev, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (05)
[5]   Precision Lamb-shift polarimeter for polarized atomic and ion beams [J].
Engels, R ;
Emmerich, R ;
Ley, J ;
Tenckhoff, G ;
Schieck, HPG ;
Mikirtytchiants, M ;
Rathmann, F ;
Seyfarth, H ;
Vassiliev, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (11) :4607-4615
[6]  
Engels R., 2002, THESIS U KOLN
[7]  
International Science and Technology Center (ISTC), 2003, 1861 ISTC
[8]   Design and performance of the Lamb-shift polarimeter [J].
Kremers, HR ;
Beijers, JPM ;
Kalantar-Nayestanaki, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 536 (03) :329-333
[9]   FINE STRUCTURE OF THE HYDROGEN ATOM .2. [J].
LAMB, WE ;
RETHERFORD, RC .
PHYSICAL REVIEW, 1951, 81 (02) :222-232
[10]   A SPIN-FILTER POLARIMETER FOR LOW-ENERGY HYDROGEN AND DEUTERIUM ION-BEAMS [J].
LEMIEUX, SK ;
CLEGG, TB ;
KARWOWSKI, HJ ;
THOMPSON, WJ ;
CROSSON, ER .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 333 (2-3) :434-442