Predictors of chest wall toxicity after stereotactic ablative radiotherapy using real-time tumor tracking for lung tumors

被引:0
作者
Park, Younghee [1 ]
Kim, Hee Jung [1 ]
Chang, Ah Ram [1 ]
机构
[1] Soonchunhyang Univ, Seoul Hosp, CyberKnife Ctr, Dept Radiat Oncol, 59 Daesagwan Ro, Seoul 140743, South Korea
来源
RADIATION ONCOLOGY | 2017年 / 12卷
关键词
Stereotactic ablative radiotherapy; Lung tumor; Chest wall toxicity; Rib fracture; Dose-volume histogram; 4D dose calculation; BODY RADIATION-THERAPY; INDUCED RIB FRACTURES; RISK-FACTORS; FRACTION SIZE; CANCER; OUTCOMES; CYBERKNIFE; LOBECTOMY; SYSTEM; IMPACT;
D O I
10.1186/s13014-017-0803-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To evaluate the incidence of chest wall toxicity after lung stereotactic ablative radiotherapy (SABR) and identify risk factors for the development of rib fracture. Methods: Thirty-nine patients with 49 lesions underwent SABR for primary or metastatic lung tumors using Cyberknife r with tumor tracking systems. Patient characteristics, treatment factors and variables obtained from dose-volume histograms (DVHs) were analyzed to find the association with chest wall toxicity. Four-dimensional (4D) dose calculations were done to investigate the effect of respiratory motion on dose to the ribs. Results: After follow-up of median 26.7 months (range: 8.4-80.0), 8 patients (20.5%) experienced rib fractures and among these patients, three (37.5%) had chest wall pain at 2-3 months after SABR. Median time to rib fracture was 13. 4 months (range: 8.0-38.5) and the 2-year actuarial risk of rib fracture was 12.2%. Dose to the 4.6 cc of the ribs (D-4.6cc) and rib volume received 160 Gy or more (V-160) were significant predictor for rib fracture. No significant differences between three-dimensional (3D) and 4D dose calculations were found. Conclusions: Parameters from DVH are useful in predicting the risk of chest wall toxicity after SABR for lung tumors. Efforts should be made to reduce the risk of the rib fracture after lung SABR.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Image-Guided Liver Stereotactic Body Radiotherapy Using VMAT and Real-Time Adaptive Tumor Gating: Evaluation of the Efficacy and Toxicity for Hepatocellular Carcinoma
    Cantaloube, Marie
    Castan, Florence
    Creoff, Morgane
    Prunaretty, Jessica
    Bordeau, Karl
    Michalet, Morgan
    Assenat, Eric
    Guiu, Boris
    Pageaux, Georges-Philippe
    Ychou, Marc
    Ailleres, Norbert
    Fenoglietto, Pascal
    Azria, David
    Riou, Olivier
    CANCERS, 2021, 13 (19)
  • [42] Simulated real-time dose reconstruction for moving tumors in stereotactic liver radiotherapy
    Skouboe, Simon
    Poulsen, Per Rugaard
    Muurholm, Casper Gammelmark
    Worm, Esben
    Hansen, Rune
    Hoyer, Morten
    Ravkilde, Thomas
    MEDICAL PHYSICS, 2019, 46 (11) : 4738 - 4748
  • [43] CHEST WALL TOXICITY FOLLOWING RISK-ADAPTED STEREOTACTIC RADIOTHERAPY FOR EARLY STAGE LUNG CANCER
    Bongers, Eva Marrit
    Haasbeek, Cornelis J.
    Lagerwaard, Frank J.
    Slotman, Ben
    Senan, Suresh
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S277 - S277
  • [44] Low Hepatic Toxicity in Primary and Metastatic Liver Cancers after Stereotactic Ablative Radiotherapy Using 3 Fractions
    Bae, Sun Hyun
    Kim, Mi-Sook
    Jang, Won Il
    Cho, Chul Koo
    Yoo, Hyung Jun
    Kim, Kum Bae
    Han, Chul Ju
    Park, Su Cheol
    Lee, Dong Han
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2015, 30 (08) : 1055 - 1061
  • [45] Real-time tumor-tracking radiotherapy with SyncTraX for primary liver tumors requiring isocenter shift
    Uchinami, Yusuke
    Miyamoto, Naoki
    Abo, Daisuke
    Morita, Ryo
    Ogawa, Koji
    Kakisaka, Tatsuhiko
    Suzuki, Ryusuke
    Miyazaki, Tomohiko
    Taguchi, Hiroshi
    Katoh, Norio
    Aoyama, Hidefumi
    JOURNAL OF RADIATION RESEARCH, 2024, 65 (01) : 92 - 99
  • [46] Clinical outcomes of stage I and IIA non-small cell lung cancer patients treated with stereotactic body radiotherapy using a real-time tumor-tracking radiotherapy system
    Katoh, Norio
    Soda, Itaru
    Tamamura, Hiroyasu
    Takahashi, Shotaro
    Uchinami, Yusuke
    Ishiyama, Hiromichi
    Ota, Kiyotaka
    Inoue, Tetsuya
    Onimaru, Rikiya
    Shibuya, Keiko
    Hayakawa, Kazushige
    Shirato, Hiroki
    RADIATION ONCOLOGY, 2017, 12
  • [47] Assessing Feasibility of Real-time Ultrasound Monitoring in Stereotactic Body Radiotherapy of Liver Tumors
    Zhong, Yahua
    Stephans, Kevin
    Qi, Peng
    Yu, Naichang
    Wong, John
    Xia, Ping
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (03) : 243 - 250
  • [48] Esophagus toxicity after stereotactic and hypofractionated radiotherapy for central lung tumors: Normal tissue complication probability modeling
    Duijm, M.
    Tekatli, H.
    Oomen-de Hoop, E.
    Verbakel, W.
    Schillemans, W.
    Slotman, B. J.
    Senan, S.
    Nuyttens, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 (02) : 233 - 238
  • [49] EVALUATION OF THE EFFECTIVENESS OF THE STEREOTACTIC BODY FRAME IN REDUCING RESPIRATORY INTRAFRACTIONAL ORGAN MOTION USING THE REAL-TIME TUMOR-TRACKING RADIOTHERAPY SYSTEM
    Bengua, Gerard
    Ishikawa, Masayori
    Sutherland, Kenneth
    Horita, Kenji
    Yamazaki, Rie
    Fujita, Katsuhisa
    Onimaru, Rikiya
    Katoh, Noriwo
    Inoue, Tetsuya
    Onodera, Shunsuke
    Shirato, Hiroki
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (02): : 630 - 636
  • [50] Local control of stereotactic body radiotherapy with dynamic tumor tracking for lung tumors: a propensity score-matched analysis
    Machitori, Yumiko
    Ito, Kei
    Kito, Satoshi
    Nakajima, Yujiro
    Saito, Makoto
    Karasawa, Katsuyuki
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2022, 52 (06) : 609 - 615