Canadian Heart Rhythm Society and Canadian Association of Radiologists Consensus Statement on Magnetic Resonance Imaging With Cardiac Implantable Electronic Devices

被引:28
作者
Verma, Atul [1 ]
Ha, Andrew C. T. [2 ]
Dennie, Carole [3 ]
Essebag, Vidal [4 ]
Exner, Derek V. [5 ]
Khan, Naeem [6 ]
Lane, Chris [7 ]
Leipsic, Jonathan [8 ]
Philippon, Francois [9 ]
Sampaio, Marcos [3 ]
Schieda, Nicola [3 ]
Seifer, Colette [10 ]
Berthiaume, Alain [3 ]
Campbell, Debra [11 ]
Chakraborty, Santanu [3 ]
机构
[1] Southlake Reg Hlth Ctr, Newmarket, ON, Canada
[2] Univ Hlth Network, Toronto, ON, Canada
[3] Ottawa Hosp, Ottawa, ON, Canada
[4] McGill Univ, Ctr Hlth, Montreal, PQ, Canada
[5] Libin Cardiovasc Inst Alberta, Calgary, AB, Canada
[6] IWK Hlth Ctr, Halifax, NS, Canada
[7] Royal Jubilee Hosp, Victoria, BC, Canada
[8] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[9] Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[10] St Boniface Gen Hosp, Winnipeg, MB, Canada
[11] Kingston Gen Hosp, Kingston, ON K7L 2V7, Canada
关键词
INDUSTRY VIEWPOINT; MEDICAL DEVICES; LOOP RECORDER; 1.5; TESLA; PACEMAKERS; MRI; SAFETY; ICDS; SYSTEM; FEASIBILITY;
D O I
10.1016/j.cjca.2014.07.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance imaging (MRI) has historically been considered contraindicated for individuals with cardiac implantable electronic devices (CIEDs) such as pacemakers and implantable defibrillators. Magnetic resonance scanners produce magnetic fields that can interact negatively with the metallic components of CIEDs. However, as CIED technology has advanced, newer MRI conditional devices have been developed that are now in clinical use and these systems have had demonstrated safety in the MRI environment. Despite the supportive data of such CIED systems, physicians remain reluctant to perform MRI scanning of conditional devices. This joint statement by the Canadian Heart Rhythm Society and the Canadian Association of Radiologists describes a collaborative process by which CIED specialists and clinics can work with radiology departments and specialists to safely perform MRI in patients with MRI conditional CIED systems. The steps required for patient and scanning preparation and the roles and responsibilities of the CIED and radiology departments are outlined. We also briefly outline the risks and a process by which patients with nonconditional CIEDs might also receive MRI in highly specialized centres. This document supports MRI in patients with MRI conditional CIEDs and offers recommendations on how this can be implemented safely and effectively.
引用
收藏
页码:1131 / 1141
页数:11
相关论文
共 37 条
  • [1] Avery J K, 1988, J Tenn Med Assoc, V81, P523
  • [2] Effects of External Electrical and Magnetic Fields on Pacemakers and Defibrillators From Engineering Principles to Clinical Practice
    Beinart, Roy
    Nazarian, Saman
    [J]. CIRCULATION, 2013, 128 (25) : 2799 - 2809
  • [3] Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients With Pacemakers and Implantable Cardioverter Defibrillators
    Cohen, Jennifer D.
    Costa, Heather S.
    Russo, Robert J.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (11) : 1631 - 1636
  • [4] Cronin Edmond M, 2012, Indian Pacing Electrophysiol J, V12, P204
  • [5] Cardiac Perforation and Lead Dislodgement after Implantation of a MR-Conditional Pacing Lead: A Single-Center Experience
    Elmouchi, Darryl A.
    Rosema, Shelly
    Vanoosterhout, Stacie M.
    Khan, Mohsin
    Davis, Alan T.
    Gauri, Andre J.
    Finta, Bohuslav
    Woelfel, Alan K.
    Chalfoun, Nagib T.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (01): : 4 - 10
  • [6] Food and drug administration perspective - Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients
    Faris, Owen P.
    Shein, Mitchell
    [J]. CIRCULATION, 2006, 114 (12) : 1232 - 1233
  • [7] Safety and efficacy of a new magnetic resonance imaging-compatible pacing system: Early results of a prospective comparison with conventional dual-chamber implant outcomes
    Forleo, Giovanni B.
    Santini, Luca
    Della Rocca, Domenico G.
    Romano, Valentina
    Papavasileiou, Lida P.
    Magliano, Giulia
    Sgueglia, Marianna
    Romeo, Francesco
    [J]. HEART RHYTHM, 2010, 7 (06) : 750 - 754
  • [8] Magnetic resonance Imaging of Implantable cardiac rhythm devices at 3.0 tesla
    Gimbel, J. Rod
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (07): : 795 - 801
  • [9] Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla
    Gimbel, J. Rod
    Bello, David
    Schmitt, Matthias
    Merkely, Bela
    Schwitter, Juerg
    Hayes, David L.
    Sommer, Torsten
    Schloss, Edward J.
    Chang, Yanping
    Willey, Sarah
    Kanal, Emanuel
    [J]. HEART RHYTHM, 2013, 10 (05) : 685 - 691
  • [10] Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker
    Gimbel, J. Rod
    [J]. EUROPACE, 2009, 11 (09): : 1241 - 1242