Endocardial atrial pacing lead, implantation and midterm follow-up in young patients with sinus node dysfunction after the Fontan procedure

被引:29
|
作者
Shah, MJ
Nehgme, R
Carboni, M
Murphy, JD
机构
[1] Univ Washington, Sch Med, Dept Pediat, Seattle, WA USA
[2] Nemours Cardiac Ctr, Wilmington, DE USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 07期
关键词
sinus node dysfunction; bradycardia; pacemaker; transvenous lead; Fontan;
D O I
10.1111/j.1540-8159.2004.00564.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the study was to investigate the results of endocardial lead implantation, lead performance, and follow-up in young patients after the Fontan procedure. A retrospective study was conducted with patients who had endocardial atrial pacing for SND and intact AVN function after Fontan from two pediatric centers. Patient demographics, pacing, and sensing data of endocardial atrial leads were analyzed at the time of pacemaker implantation and follow-up visits. Fifteen patients (weight 42.6 +/- 35 kg) had transvenous endocardial atrial lead implantation at an average age of 11.4 +/- 6.5 years. Active-fixation leads were used in all patients and steroid elution was present in 12 (80%) patients. Adequate P wave sensing was obtained in patients with sinus rhythm (n = 10); the remaining four patients had junctional rhythm without measurable P waves. Lead failure was not observed in any patient during the follow-up period of 2.9 +/- 2.1 years. The energy threshold at implantation was 1.46 +/- 1.5 muJ, 1.54 +/- 0.75 muJ at 3 months, 0.62 +/- 0.45 muJ at 1 year, 0.72 +/- 0.65 muJ at 2 years, 0.75 +/- 0.55 muJ at 3 years, and 0.8 +/- 0.85 muJ at 5 years postimplant. The lead impedance was 648 +/- 298 Omega at implantation, 714 +/- 163 Omega at 3 months, 744 +/- 195 Omega at 1 year, 734 +/- 198 Omega at 2 years, 800 +/- 142 Omega at 3 years and 830 +/- 200 Omega 5 years postimplant. Anticoagulation therapy (aspirin n = 5, warfarin n = 8) was continued by 13 patients. Complications consisted of a pneumothorax at implantation and a transient ischemic attack in one patient 4 years after pacemaker implant. Endocardial atrial leads offer low energy thresholds and can be implanted relatively safely in Fontan patients.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 46 条
  • [41] Safety of Deferring the Reimplantation of Pacing Systems After Their Removal for Infectious Complications in Selected Patients: A 1-Year Follow-Up Study
    Marijon, Eloi
    De Guillebon, Maxime
    Bordachar, Pierre
    Jacob, Sophie
    Vahdat, Olivier
    Sidobre, Laurent
    Deplagne, Antoine
    Combes, Nicolas
    Albenque, Jean-Paul
    Clementy, Jacques
    Haissaguerre, Michel
    Ritter, Philippe
    Boveda, Serge
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (05) : 540 - 544
  • [42] Neutrophil-to-Lymphocyte and Platelet-to-Lymphocyte Ratio in Univentricular Patients From Birth to Follow-Up After Fontan-Predicting Lymphatic Abnormalities
    Moosmann, Julia
    Schroeder, Christian
    Cesnjevar, Robert
    Rottermann, Kathrin
    Weigelt, Annika
    Dittrich, Sven
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [43] His bundle pacing is still relevant for patients with atrial fibrillation and bradycardia without prior atrioventricular nodal ablation: Data from mid-term follow-up
    Soral, Tomasz
    Gardas, Rafal
    Golba, Krzysztof S.
    Kulesza, Piotr
    Biernat, Jolanta
    Loboda, Danuta
    POLISH HEART JOURNAL-KARDIOLOGIA POLSKA, 2024, 82 (11): : 1119 - 1126
  • [44] Atrioventricular Block Necessitating Chronic Ventricular Pacing After Tricuspid Valve Surgery in Patients With a Systemic Right Ventricle: Long-Term Follow-Up
    Nederend, Marieke
    Jongbloed, Monique R. M.
    Kies, Philippine
    Vliegen, Hubert W.
    Bouma, Berto J.
    Regeer, Madelien V.
    Koolbergen, Dave R.
    Hazekamp, Mark G.
    Schalij, Martin J.
    Egorova, Anastasia D.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [45] INCIDENCE OF SINUS NODE DYSFUNCTION IN PATIENTS WITH LONG-STANDING , PERSISTENT ATRIAL FIBRILLATION WHO REQUIRE SIMULTANEOUS SURGICAL CORRECTION OF MITRAL AND TRICUSPID VALVE DEFECTS AND THE "MAZE IIIB" PROCEDURE
    Bockeria, L. A.
    Kulikov, A. A.
    KARDIOLOGIYA, 2017, 57 : 40 - 48
  • [46] Effect of tricuspid regurgitation and right ventricular dysfunction on long-term mortality in patients undergoing cardiac devices implantation: >10-year follow-up study
    Papageorgiou, Nikolaos
    Falconer, Debbie
    Wyeth, Nikolas
    Lloyd, Guy
    Pellerin, Denis
    Speechly-Dick, Elsya
    Segal, Oliver R.
    Lowe, Martin
    Rowland, Edward
    Lambiase, Pier D.
    Chow, Anthony W.
    Bhattacharyya, Sanjeev
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 319 : 52 - 56