Endocardial atrial pacing lead, implantation and midterm follow-up in young patients with sinus node dysfunction after the Fontan procedure

被引:29
|
作者
Shah, MJ
Nehgme, R
Carboni, M
Murphy, JD
机构
[1] Univ Washington, Sch Med, Dept Pediat, Seattle, WA USA
[2] Nemours Cardiac Ctr, Wilmington, DE USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 07期
关键词
sinus node dysfunction; bradycardia; pacemaker; transvenous lead; Fontan;
D O I
10.1111/j.1540-8159.2004.00564.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the study was to investigate the results of endocardial lead implantation, lead performance, and follow-up in young patients after the Fontan procedure. A retrospective study was conducted with patients who had endocardial atrial pacing for SND and intact AVN function after Fontan from two pediatric centers. Patient demographics, pacing, and sensing data of endocardial atrial leads were analyzed at the time of pacemaker implantation and follow-up visits. Fifteen patients (weight 42.6 +/- 35 kg) had transvenous endocardial atrial lead implantation at an average age of 11.4 +/- 6.5 years. Active-fixation leads were used in all patients and steroid elution was present in 12 (80%) patients. Adequate P wave sensing was obtained in patients with sinus rhythm (n = 10); the remaining four patients had junctional rhythm without measurable P waves. Lead failure was not observed in any patient during the follow-up period of 2.9 +/- 2.1 years. The energy threshold at implantation was 1.46 +/- 1.5 muJ, 1.54 +/- 0.75 muJ at 3 months, 0.62 +/- 0.45 muJ at 1 year, 0.72 +/- 0.65 muJ at 2 years, 0.75 +/- 0.55 muJ at 3 years, and 0.8 +/- 0.85 muJ at 5 years postimplant. The lead impedance was 648 +/- 298 Omega at implantation, 714 +/- 163 Omega at 3 months, 744 +/- 195 Omega at 1 year, 734 +/- 198 Omega at 2 years, 800 +/- 142 Omega at 3 years and 830 +/- 200 Omega 5 years postimplant. Anticoagulation therapy (aspirin n = 5, warfarin n = 8) was continued by 13 patients. Complications consisted of a pneumothorax at implantation and a transient ischemic attack in one patient 4 years after pacemaker implant. Endocardial atrial leads offer low energy thresholds and can be implanted relatively safely in Fontan patients.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 46 条
  • [21] Cardiac pacing strategies and post-implantation risk of atrial fibrillation and heart failure events in sinus node dysfunction patients: a collaborative analysis of over 6000 patients
    Chen, Shaojie
    Wang, Zhenglong
    Kiuchi, Marcio Galindo
    Andrea, Bruno Rustum
    Krucoff, Mitchell W.
    Liu, Shaowen
    Puererfellner, Helmut
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (08) : 687 - 698
  • [22] Permanent Pacemaker Implantations after Catheter Ablation in Patients with Atrial Fibrillation Associated with Underlying Sinus Node Dysfunction
    Hwang, Tae Hyun
    Yu, Hee Tae
    Kim, Tae-Hoon
    Uhm, Jae-Sun
    Kim, Jong-Youn
    Joung, Boyoung
    Lee, Moon-Hyoung
    Pak, Hui-Nam
    KOREAN CIRCULATION JOURNAL, 2020, 50 (04) : 346 - 357
  • [23] Three-year incidence of pacemaker implantation in patients with atrial fibrillation and sinus node dysfunction receiving ablation versus antiarrhythmic drugs
    Okumus, Nazli Kubra
    Zeitler, Emily P.
    Moustafa, Abdelmoniem
    Iglesias, Maximiliano
    Khanna, Rahul
    Rong, Yiran
    Karim, Saima
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (07) : 1593 - 1602
  • [24] Incidence of atrial fibrillation in patients with different mode of pacing. Long-term follow-up
    Folino, AF
    Buja, G
    Dal Corso, L
    Nava, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01): : 260 - 263
  • [25] Effects of right low atrial septal vs. right atrial appendage pacing on atrial mechanical function and dyssynchrony in patients with sinus node dysfunction and paroxysmal atrial fibrillation
    Wang, Mei
    Siu, Chung-Wah
    Lee, Kathy L. F.
    Yue, Wen-Sheng
    Yan, Guo-Hui
    Lee, Stephen
    Lau, Chu-Pak
    Tse, Hung-Fat
    EUROPACE, 2011, 13 (09): : 1268 - 1274
  • [26] Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction
    Kim, Won Ho
    Joung, Boyoung
    Shim, Jaemin
    Park, Jong Sung
    Hwang, Eui-Seock
    Pak, Hui-Nam
    Kim, Sungsoon
    Lee, Moonhyoung
    YONSEI MEDICAL JOURNAL, 2010, 51 (06) : 832 - 837
  • [27] The importance of frequent follow-up in the first year after pacemaker implantation upon detection of atrial tachyarrhythmia
    Nowek, Anna
    Chudzik, Michal
    Wranicz, Jerzy K.
    MEDICAL STUDIES-STUDIA MEDYCZNE, 2016, 32 (03) : 184 - 188
  • [28] Closed-loop stimulation as a physiological rate-modulated pacing approach based on intracardiac impedance to lower the atrial tachyarrhythmia burden in patients with sinus node dysfunction and atrial fibrillation
    Ikeda, Shota
    Nogami, Akihiko
    Inoue, Kosuke
    Kowase, Shinya
    Kurosaki, Kenji
    Mukai, Yasushi
    Tsutsui, Hiroyuki
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (05) : 1187 - 1194
  • [29] Clinical safety and efficacy of single-chamber atrial pacing-in sick sinus syndrome:: Long-term follow-up
    Moriñigo, JL
    Arribas, A
    Ledesma, C
    Sánchez, PL
    Martín, F
    Luengo, CM
    REVISTA ESPANOLA DE CARDIOLOGIA, 2002, 55 (12): : 1267 - 1272
  • [30] Primary Prevention of Atrial Fibrillation: Does the Atrial Lead Position Influence the Incidence of Atrial Arrhythmias in Patients with Sinus Node Dysfunction? Results from the PASTA Trial
    Spitzer, Stefan G.
    Wacker, Petra
    Gazarek, Steffen
    Malinowski, Klaus
    Schibgilla, Volker
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (12): : 1553 - 1561