Endocardial atrial pacing lead, implantation and midterm follow-up in young patients with sinus node dysfunction after the Fontan procedure

被引:29
|
作者
Shah, MJ
Nehgme, R
Carboni, M
Murphy, JD
机构
[1] Univ Washington, Sch Med, Dept Pediat, Seattle, WA USA
[2] Nemours Cardiac Ctr, Wilmington, DE USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 07期
关键词
sinus node dysfunction; bradycardia; pacemaker; transvenous lead; Fontan;
D O I
10.1111/j.1540-8159.2004.00564.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the study was to investigate the results of endocardial lead implantation, lead performance, and follow-up in young patients after the Fontan procedure. A retrospective study was conducted with patients who had endocardial atrial pacing for SND and intact AVN function after Fontan from two pediatric centers. Patient demographics, pacing, and sensing data of endocardial atrial leads were analyzed at the time of pacemaker implantation and follow-up visits. Fifteen patients (weight 42.6 +/- 35 kg) had transvenous endocardial atrial lead implantation at an average age of 11.4 +/- 6.5 years. Active-fixation leads were used in all patients and steroid elution was present in 12 (80%) patients. Adequate P wave sensing was obtained in patients with sinus rhythm (n = 10); the remaining four patients had junctional rhythm without measurable P waves. Lead failure was not observed in any patient during the follow-up period of 2.9 +/- 2.1 years. The energy threshold at implantation was 1.46 +/- 1.5 muJ, 1.54 +/- 0.75 muJ at 3 months, 0.62 +/- 0.45 muJ at 1 year, 0.72 +/- 0.65 muJ at 2 years, 0.75 +/- 0.55 muJ at 3 years, and 0.8 +/- 0.85 muJ at 5 years postimplant. The lead impedance was 648 +/- 298 Omega at implantation, 714 +/- 163 Omega at 3 months, 744 +/- 195 Omega at 1 year, 734 +/- 198 Omega at 2 years, 800 +/- 142 Omega at 3 years and 830 +/- 200 Omega 5 years postimplant. Anticoagulation therapy (aspirin n = 5, warfarin n = 8) was continued by 13 patients. Complications consisted of a pneumothorax at implantation and a transient ischemic attack in one patient 4 years after pacemaker implant. Endocardial atrial leads offer low energy thresholds and can be implanted relatively safely in Fontan patients.
引用
收藏
页码:949 / 954
页数:6
相关论文
共 46 条
  • [1] Sinus Node Dysfunction after Successful Atrial Flutter Ablation during Follow-Up: Clinical Characteristics and Predictors
    Li, Guan-Yi
    Chung, Fa-Po
    Chao, Tze-Fan
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Lo, Li-Wei
    Hu, Yu-Feng
    Tuan, Ta-Chuan
    Liao, Jo-Nan
    Chang, Ting-Yung
    Kuo, Ling
    Wu, Cheng-, I
    Liu, Chih-Min
    Liu, Shin-Huei
    Cheng, Wen-Han
    Chen, Shih-Ann
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (11)
  • [2] Prevalence and predictors of atrial arrhythmias in patients with sinus node dysfunction and atrial pacing
    Bukari, Abdallah
    Wali, Eisha
    Deshmukh, Amrish
    Aziz, Zaid
    Broman, Michael
    Beaser, Andrew
    Upadhyay, Gaurav
    Nayak, Hemal
    Tung, Roderick
    Ozcan, Cevher
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 365 - 371
  • [3] Prevalence and predictors of atrial arrhythmias in patients with sinus node dysfunction and atrial pacing
    Abdallah Bukari
    Eisha Wali
    Amrish Deshmukh
    Zaid Aziz
    Michael Broman
    Andrew Beaser
    Gaurav Upadhyay
    Hemal Nayak
    Roderick Tung
    Cevher Ozcan
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 365 - 371
  • [4] Incidence and predictors of pacemaker implantation at follow-up after reversible high-degree sinus node dysfunction or atrioventricular block
    Habbout, Ahmed
    Sagnard, Audrey
    Pommier, Thibaut
    Didier, Romain
    Garnier, Fabien
    Fichot, Marie
    Bertaux, Geraldine
    Laurent, Gabriel
    Guenancia, Charles
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (08): : 994 - 1002
  • [5] Benefits of Chronic Atrial Pacing in Fontan Physiology with Sinus Node Dysfunction and Preserved Ejection Fraction: Novel Therapeutic Approach for Failing Fontan
    Ohuchi, Hideo
    Saku, Keita
    Miyazaki, Aya
    Mori, Aki
    Kato, Yoshiaki
    Sakaguchi, Heima
    Shiraishi, Isao
    Kurosaki, Kenichi
    PEDIATRIC CARDIOLOGY, 2025,
  • [6] A comparison of AAIR versus DDDR pacing for patients with sinus node dysfunction: a long-term follow-up study
    Mutagaywa, Reuben Kato
    Tumaini, Basil
    Chin, Ashley
    CARDIOVASCULAR JOURNAL OF AFRICA, 2021, 32 (01) : 17 - 20
  • [7] Sinus node dysfunction in patients with Fontan circulation: could heart rate variability be a predictor for pacemaker implantation?
    Dahlqvist, Jenny Alenius
    Wiklund, Urban
    Karlsson, Marcus
    Hanseus, Katarina
    Stromvall-Larsson, Eva
    Nygren, Anders
    Eliasson, Hakan
    Rydberg, Annika
    PEDIATRIC CARDIOLOGY, 2019, 40 (04) : 685 - 693
  • [8] Sinus node dysfunction in patients with Fontan circulation: could heart rate variability be a predictor for pacemaker implantation?
    Jenny Alenius Dahlqvist
    Urban Wiklund
    Marcus Karlsson
    Katarina Hanséus
    Eva Strömvall-Larsson
    Anders Nygren
    Håkan Eliasson
    Annika Rydberg
    Pediatric Cardiology, 2019, 40 : 685 - 693
  • [9] Single chamber atrial pacing:: A realistic option in sinus node disease:: A long-term follow-up study of 213 patients
    Hoeijer, Carl J.
    Hoeglund, Peter
    Schueller, Hans
    Brandt, Johan
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (06): : 740 - 747
  • [10] Pacing mode survival in patients with single chamber atrial pacemaker for sinus node dysfunction
    Velayuthan, Ramanathan
    Sukumar, Suresh Kumar
    Bootla, Dinakar
    Balaguru, Sridhar
    Anantharaj, Avinash
    Satheesh, Santhosh
    Selvaraj, Raja J.
    INDIAN HEART JOURNAL, 2024, 76 (01) : 27 - 30