Wireless Pressure Ulcer Sensor Validation in an Animal Model

被引:8
作者
Hickle, Kelli [1 ]
Slamin, Robert [1 ]
Baez, Angel [1 ]
Sen, Devdip [2 ]
Evan-Browning, Eric [3 ]
Tessier, Heather [1 ]
Mendelson, Yitzhak [4 ]
McNeill, John [2 ]
Dunn, Raymond [1 ]
机构
[1] Univ Massachusetts, Dept Surg, Div Plast Surg, Med Sch, Worcester, MA USA
[2] Worcester Polytech Inst, Dept Elect & Comp Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Sch, Dept Pathol, Worcester, MA USA
[4] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
关键词
pressure injury; pressure sensor; pressure ulcer; prevention; Sprague-Dawley rats; wireless communication; SKIN; INJURY; SORES;
D O I
10.1097/SAP.0000000000001882
中图分类号
R61 [外科手术学];
学科分类号
摘要
Pressure ulcers are increasingly prevalent in an aging population. The most commonly used method of pressure ulcer prevention is pressure off-loading achieved by physically turning bedbound patients or by using expensive, single application devices such as wheelchair cushions. Our aim is to approach the problem of pressure ulcer prevention in a new way: a wireless sensor worn by the patient at locations susceptible to pressure injury. The sensor will monitor local pressure over time and transmits the data wirelessly to a base station (in a hospital setting) or smartphone (for home care). When a condition that would be harmful to tissue is reached, an alert would enable immediate direct intervention to prevent development of a pressure ulcer. The goal of this study was to validate the sensor's use in a live animal model and to lay the foundation for building time-pressure curves to predict the probability of pressure injury. Sprague-Dawley rats underwent surgical implantation of bilateral steel discs deep to the latissimus dorsi muscles. After the animals recovered from the surgical procedure, pressure was applied to the overlying tissue using magnets of varying strengths (30-150 mm Hg) for between 1 and 8 hours. Our sensor was placed on the skin prior to magnet application to wirelessly collect data regarding pressure and time. Three days after pressure application, animals were killed, injuries were graded clinically, and biopsies were collected for histological analysis. Results reveal that all animals with magnet application for more than 2 hours had clinical evidence of ulceration. Similarly, histological findings of hemorrhage were associated with increased time of pressure application. However, at high pressures (120-150 mm Hg), there were ischemic changes within the muscular layer without corresponding skin ulceration. We have developed a wireless sensor that can be placed on any at-risk area of the body and has the potential to alert caregivers when patients are at risk of developing a pressure injury. Our sensor successfully transmitted pressure readings wirelessly in a live, mobile animal. Future studies will focus on safety and efficacy with human use and development of algorithms to predict the probability of pressure ulcer formation.
引用
收藏
页码:S215 / S221
页数:7
相关论文
共 38 条
[1]   Microcirculatory responses of sacral tissue in healthy individuals and inpatients on different pressure-redistribution mattresses [J].
Bergstrand, S. ;
Kallman, U. ;
Ek, A-C ;
Engstrom, M. ;
Lindgren, M. .
JOURNAL OF WOUND CARE, 2015, 24 (08) :346-358
[2]   Patient and organisational variables associated with pressure ulcer prevalence in hospital settings: a multilevel analysis [J].
Bredesen, Ida Marie ;
Bjoro, Karen ;
Gunningberg, Lena ;
Hofoss, Dag .
BMJ OPEN, 2015, 5 (08)
[3]   High cost of stage IV pressure ulcers [J].
Brem, Harold ;
Maggi, Jason ;
Nierman, David ;
Rolnitzky, Linda ;
Bell, David ;
Rennert, Robert ;
Golinko, Michael ;
Yan, Alan ;
Lyder, Courtney ;
Vladeck, Bruce .
AMERICAN JOURNAL OF SURGERY, 2010, 200 (04) :473-477
[4]  
Butler G, 2010, US Patent, Patent No. [7,761,945, 7761945]
[5]   Mechanically Flexible Wireless Multisensor Platform for Human Physical Activity and Vitals Monitoring [J].
Chuo, Yindar ;
Marzencki, Marcin ;
Hung, Benny ;
Jaggernauth, Camille ;
Tavakolian, Kouhyar ;
Lin, Philip ;
Kaminska, Bozena .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2010, 4 (05) :281-294
[6]   Pressure ulcer and wounds reporting in NHS hospitals in England part 2: Survey of monitoring systems [J].
Coleman, Susanne ;
Smith, Isabelle L. ;
Nixon, Jane ;
Wilson, Lyn ;
Brown, Sarah .
JOURNAL OF TISSUE VIABILITY, 2016, 25 (01) :16-25
[7]  
Crivello M, 2016, NEBEC C
[8]   PRESSURE SORES AND PARAPLEGIA - AN EXPERIMENTAL-MODEL [J].
DANIEL, RK ;
WHEATLEY, D ;
PRIEST, D .
ANNALS OF PLASTIC SURGERY, 1985, 15 (01) :41-49
[9]  
Drennan DB, 2013, US Patent, Patent No. [8,535,246, 8535246]
[10]   Revised National Pressure Ulcer Advisory Panel Pressure Injury Staging System Revised Pressure Injury Staging System [J].
Edsberg, Laura E. ;
Black, Joyce M. ;
Goldberg, Margaret ;
McNichol, Laurie ;
Moore, Lynn ;
Sieggreen, Mary .