High Incidence of Hypoglycemia in Stable Insulin-Treated Type 2 Diabetes Mellitus: Continuous Glucose Monitoring vs. Self-Monitored Blood Glucose. Observational Prospective Study

被引:33
作者
Pazos-Couselo, Marcos [1 ]
Manuel Garcia-Lopez, Jose [1 ]
Gonzalez-Rodriguez, Maria [1 ]
Gude, Francisco [2 ]
Manuel Mayan-Santos, Jose [3 ]
Rodriguez-Segade, Santiago [4 ]
Rodriguez-Garcia, Javier [4 ]
Casanueva, Felipe [1 ,5 ]
机构
[1] Hosp Conxo, Endocrinol & Nutr Serv, Santiago De Compostela 15702, Spain
[2] Hosp Conxo, Clin Epidemiol Unit, Santiago De Compostela 15702, Spain
[3] Univ Santiago de Compostela, Gerontol Dept, Santiago De Compostela, Spain
[4] Univ Santiago de Compostela, Biochem & Mol Biol, Santiago De Compostela, Spain
[5] Physiopathol Obes & Nutr Biomed Res Network Conso, Santiago De Compostela, Spain
关键词
continuous glucose monitoring; hypoglycemia; self-monitored blood glucose; type; 2; diabetes; PREDICTORS; FREQUENCY; SYSTEM;
D O I
10.1016/j.jcjd.2015.05.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Hypoglycemia is a limiting factor in the achievement of strict glycemic control. The primary objective of this 9-week study was to determine the frequency of hypoglycemia in patients with stable insulin-treated type 2 diabetes mellitus by comparing self-monitored blood glucose (SMBG) measurement with continuous glucose monitoring (CGM). Methods: This was an observational prospective study. Included in the study were 63 stable, insulin-treated patients with type 2 diabetes. They were instructed to record 2 daily capillary blood glucose readings, pre-and/or postprandial, in a sequential way during 8 consecutive weeks. A CGM system was worn during an additional week. We evaluated the frequency of hypoglycemia using the 8-week SMBG profile and the 1 CGM week. Results: SMBG revealed that 50% of the patients had experienced hypoglycemia. CGM found hypoglycemia in 59% of patients. Significantly higher percentages of hyperglycemic and hypoglycemic episodes were detected by CGM than by capillary blood glucose measurements (61.1% vs. 50.8%; p = 0.047) and (3.8% vs. 1.7%; p = 0.016); 33% of patients experienced nocturnal hypoglycemia, and 19% of patients who had no data concerning hypoglycemia recorded in the capillary blood glucose diary had experienced hypoglycemia as measured by CGM, and the hypoglycemia occurred mainly during the nocturnal period. Conclusions: In stable well-controlled, insulin-treated patients with type 2 diabetes, CGM showed higher numbers of hypoglycemic events than did SMBG, especially at night. CGM is a useful tool that provides clinically valuable information about glucose control in these patients. (C) 2015 Canadian Diabetes Association
引用
收藏
页码:428 / 433
页数:6
相关论文
共 24 条
[1]   Standards of Medical Care in Diabetes-2014 [J].
不详 .
DIABETES CARE, 2014, 37 :S14-S80
[2]   Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes [J].
Bode, BW ;
Schwartz, S ;
Stubbs, HA ;
Block, JE .
DIABETES CARE, 2005, 28 (10) :2361-2366
[3]  
Bonakdaran Shokoufeh, 2009, Indian J Med Sci, V63, P66
[4]   A nine country study of the burden of non-severe nocturnal hypoglycaemic events on diabetes management and daily function [J].
Brod, M. ;
Wolden, M. ;
Christensen, T. ;
Bushnell, D. M. .
DIABETES OBESITY & METABOLISM, 2013, 15 (06) :546-557
[5]   The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control [J].
Chico, A ;
Vidal-Ríos, P ;
Subirà, M ;
Novials, A .
DIABETES CARE, 2003, 26 (04) :1153-1157
[6]   Multicentre, randomised, controlled study of the impact of continuous sub-cutaneous glucose monitoring (GlucoDay®) on glycaemic control in type 1 and type 2 diabetes patients [J].
Cosson, E. ;
Hamo-Tchatchouang, E. ;
Dufaitre-Patouraux, L. ;
Attali, J. -R. ;
Paries, J. ;
Schaepelynck-Belicar, P. .
DIABETES & METABOLISM, 2009, 35 (04) :312-318
[7]   Frequency and predictors of hypoglycaemia in Type 1 and insulin-treated Type 2 diabetes: A population-based study [J].
Donnelly, LA ;
Morris, AD ;
Frier, BM ;
Ellis, JD ;
Donnan, PT ;
Durrant, R ;
Band, MM ;
Reekie, G ;
Leese, GP .
DIABETIC MEDICINE, 2005, 22 (06) :749-755
[8]   Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database [J].
Evans, JMM ;
Newton, RW ;
Ruta, DA ;
MacDonald, TM ;
Stevenson, RJ ;
Morris, AD .
BMJ-BRITISH MEDICAL JOURNAL, 1999, 319 (7202) :83-86
[9]   Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor [J].
Garg, S ;
Zisser, H ;
Schwartz, S ;
Bailey, T ;
Kaplan, R ;
Ellis, S ;
Jovanovic, L .
DIABETES CARE, 2006, 29 (01) :44-50
[10]   Relationship of fasting and hourly glucose levels to HbA1c values blood [J].
Garg, Satish ;
Jovanovic, Lots .
DIABETES CARE, 2006, 29 (12) :2644-2649