A new 1D analytical model for investigating the long term heat transfer rate of a borehole ground heat exchanger by Green's function method

被引:24
作者
Dehghan, Babak B. [1 ,2 ]
Kukrer, Ergin [1 ,2 ]
机构
[1] Istanbul Tech Univ, Fac Mech Engn, Istanbul, Turkey
[2] Istanbul Tech Univ, Energy Inst, Istanbul, Turkey
关键词
Ground source heat pump; Green's function method; Borehole; Borehole ground heat exchanger; Performance prediction; PUMP SYSTEMS; NUMERICAL-SIMULATION; BUILDINGS; STORAGE;
D O I
10.1016/j.renene.2016.11.002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In ground source heat pump (GSHP) applications, long term performance prediction of a borehole is an important issue since performance of a borehole ground heat exchanger decreases by the life time of the system. Therefore, it is important to find a reliable method determining the long term performance of a borehole. In this study, a new 1D analytical expression for heat transfer rate (HTR) per unit length of a borehole is derived at constant borehole wall temperature condition by using Green's function method (GFM). A 50 m-depth borehole containing U-tube polyethylene pipes with 32 mm outside and 26.6 inside diameter is considered. Experimental measurements are done by pumping warm water of 40 degrees C into the pipe system for 120 h. Variation of HTR value per length of borehole in time is determined from the experimental data. Analytical results based on GFM are verified by experimental measurements. Based on the validated analytical model, long term HTR values (thermal performance) per length of borehole are predicted. Verification of numeric and experiment results illustrates the compromise of them. Furthermore, temperature distribution around borehole is investigated by using new given analytical expression. Engineers can use analytical models that are given in this study in designing of GSHP systems. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:615 / 621
页数:7
相关论文
共 29 条
[1]   Experimental and computational investigation of multi U-tube boreholes [J].
Aydin, Murat ;
Sisman, Altug .
APPLIED ENERGY, 2015, 145 :163-171
[2]   Reducing the global warming impact of a household heat pump dishwasher using hydrocarbon refrigerants [J].
Bengtsson, Peder ;
Eikevik, Trygve .
APPLIED THERMAL ENGINEERING, 2016, 99 :1295-1302
[3]   Techno-economic and spatial analysis of vertical ground source heat pump systems in Germany [J].
Blum, Philipp ;
Campillo, Gisela ;
Koelbel, Thomas .
ENERGY, 2011, 36 (05) :3002-3011
[4]  
Carslaw H.S., 1947, HEAT CONDUCTION SOLI
[5]   Ground source heat pumps as high efficient solutions for building space conditioning and for integration in smart grids [J].
Carvalho, Anabela D. ;
Moura, Pedro ;
Vaz, Gilberto C. ;
de Almeida, Anibal T. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 103 :991-1007
[6]   Heat transfer analysis of a vertical ground heat exchanger using numerical simulation and multiple regression model [J].
Chen, Shangyuan ;
Mao, Jinfeng ;
Han, Xu .
ENERGY AND BUILDINGS, 2016, 129 :81-91
[7]   Revised heat transfer modeling of double-U vertical ground-coupled heat exchangers [J].
Conti, P. ;
Testi, D. ;
Grassi, W. .
APPLIED THERMAL ENGINEERING, 2016, 106 :1257-1267
[8]   Analysis on the transient heat transfer process inside and outside the borehole for a vertical U-tube ground heat exchanger under short-term heat storage [J].
Dai, L. H. ;
Shang, Y. ;
Li, X. L. ;
Li, S. F. .
RENEWABLE ENERGY, 2016, 87 :1121-1129
[9]  
De Carli M, 2010, RENEW ENERG, V35, P1537, DOI [10.1016/j.renene.2009.11.034, 10.1016/j.renene2009.11.034]
[10]  
Dehghan B., 2015, WORLD GEOTH C