The effect of a bacterial contamination on the formation of capsular contracture with polyurethane breast implants in comparison with textured silicone implants: An animal study

被引:39
作者
Bergmann, Philipp A. [1 ]
Tamouridis, Georgious [1 ]
Lohmeyer, Joern A. [4 ]
Mauss, Karl L. [2 ]
Becker, Benedikt [2 ]
Knobloch, Johannes [3 ]
Mailaender, Peter [2 ]
Siemers, Frank [1 ]
机构
[1] Berufsgenossenschaftl Kliniken Bergmannstrost, Dept Plast & Handsurg, Burn Unit, D-06112 Halle, Saale, Germany
[2] Univ Klinikum Schleswig Holstein, Burn Unit, D-23538 Lubeck, Germany
[3] Univ Klinikum Schleswig Holstein, Inst Microbiol, D-23538 Lubeck, Germany
[4] AGAPLESION Diakonieklinikum Hamburg, Dept Plast Surg, Hamburg, Germany
关键词
Capsular contracture; Polyurethane silicone implants; Silicone implants; Biofilm; Staphylococcus epidermidis; COVERED MAMMARY IMPLANTS; SYNOVIAL METAPLASIA; SUBCLINICAL INFECTION; AUGMENTATION MAMMAPLASTY; SMOOTH SILICONE; GEL IMPLANTS; PROSTHESIS; SURFACE; MODEL; RECONSTRUCTION;
D O I
10.1016/j.bjps.2014.05.040
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: One of the most common complications following breast augmentation is capsular contracture. The subclinical infection of the implant is often considered to be one of the main risk factors. It is believed that polyurethane (PU) implants, because of their larger foam-like surface, have lower capsular contracture rates due to better tissue integration. It remains unclear if bacterial contamination and biofilm formation result in higher capsular contracture rates under the condition of the increased surface of PU implants compared to textured silicone-gel implants. The effect of this bacterial contamination was examined in an animal-based study. Methods: A total of 80 mini implants (40 textured silicone-gel implants and 40 PU implants) were implanted in the dorsum of female Wistar rats. In each group, 20 implants were inoculated before implantation with a standard amount of Staphylococcus epidermidis. Capsules and implants were explanted after 60 days, followed by double-blind histological, immunohistochemical, and microbiological examinations. Results: Macroscopic separation of the total capsule in the textured implant group was possible whereas the growth of surrounding tissue into the foam structure of PU implants made separation in that group difficult. After contamination, a thicker capsule could be observed in both groups without significant differences. Histologically, capsules around PU implants showed significantly lower expression of parallel myofibrils. We were able to describe a significant higher infiltration with inflammatory cells in capsules around PU implants both with and without contamination. Microbiological investigations revealed positive growth of S. epidermidis around one PU implant without related signs of capsular contracture. Discussion: This study demonstrates that aside from the surface of silicone implants, bacterial contamination has major impact on the architecture of capsule formation. In our study, we were able to demonstrate that bacterial contamination leads to a thicker capsule and an increased tissue reaction with a higher amount of inflammatory cells. However, a resulting bacterial infection was only demonstrated in one case and had an insignificant influence on capsule architecture. The observed inflammatory reaction around PU implants was observed as a nonbacterial, granulomatose foreign body reaction. EBM rating: Level I: Evidence obtained from at least one properly designed randomized controlled trial. (C) 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1364 / 1370
页数:7
相关论文
共 55 条
[1]   Discussion: Subclinical (Biofilm) Infection Causes Capsular Contracture in a Porcine Model following Augmentation Mammaplasty [J].
Adams, William P., Jr. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 126 (03) :843-844
[2]   Novel Rat Model of Methicillin-Resistant Staphylococcus aureus-Infected Silicone Breast Implants: A Study of Biofilm Pathogenesis [J].
Arad, Ehud ;
Navon-Venezia, Shiri ;
Gur, Eyal ;
Kuzmenko, Boris ;
Glick, Rivka ;
Frenkiel-Krispin, Daphna ;
Kramer, Eyal ;
Carmeli, Yehuda ;
Barnea, Yoav .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (02) :205-214
[3]   A NEW TYPE OF BREAST PROSTHESIS - PRELIMINARY REPORT [J].
ASHLEY, FL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1970, 45 (05) :421-&
[4]   Breast Implant Surface Development: Perspectives on Development and Manufacture [J].
Barr, Simon ;
Bayat, Ardeshir .
AESTHETIC SURGERY JOURNAL, 2011, 31 (01) :56-67
[5]   Histological and Immunohistochemical Study of Capsular Contracture in an Animal Model - A Comparison of two Implants According to a Modification of Wilflingseder's Classification [J].
Bergmann, P. A. ;
Liodaki, M. E. ;
Mauss, K. L. ;
Lange, T. ;
Gebhard, M. ;
Mailaender, P. ;
Siemers, F. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2012, 44 (04) :220-226
[6]   Breast augmentation: Part I - a review of the silicone prosthesis [J].
Berry, M. G. ;
Davies, D. M. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2010, 63 (11) :1761-1768
[8]  
BRAND KG, 1988, CLIN PLAST SURG, V15, P533
[9]   THE CAPSULE QUALITY OF SALINE-FILLED SMOOTH SILICONE, TEXTURED SILICONE, AND POLYURETHANE IMPLANTS IN RABBITS - A LONG-TERM STUDY [J].
BUCKY, LP ;
EHRLICH, HP ;
SOHONI, S ;
MAY, JW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 93 (06) :1123-1131
[10]  
Bucky LP, 1994, PLAST RECONSTR SURG, V93, P32