Derivatization of ethinylestradiol with dansyl chloride to enhance electrospray ionization: Application in trace analysis of ethinylestradiol in rhesus monkey plasma

被引:175
作者
Anari, MR [1 ]
Bakhtiar, R [1 ]
Zhu, B [1 ]
Huskey, S [1 ]
Franklin, RB [1 ]
Evans, DC [1 ]
机构
[1] Merck Res Labs, Preclin Drug Metab, Rahway, NJ 07065 USA
关键词
D O I
10.1021/ac025712h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The extensive metabolism and administration of low doses of ethinylestradiol (EE) in preclinical animal species necessitates a sensitive analytical method to quantify the drug at low picogram-per-milliliter concentrations in biological matrixes. A highly sensitive and accurate method based on the derivatization of EE with dansyl chloride coupled with liquid chromatography/tandem mass spectrometxy is described. The dansyl derivatization of EE introduced a basic secondary nitrogen into the molecule that was readily ionized in commonly used acidic HPLC mobile phases. The derivative showed an intense protonated molecular ion at m/z 530 under positive turbo ion spray ionization. The collision-induced dissociation of this ion formed a distinctive product at m/z 171, corresponding to the protonated 5-(dimethylamino)naphthalene moiety. The selected reaction monitoring, based on the m/z 530 --> 171 transition, was highly specific, for EE, since no background signal was observed from blank plasma obtained from rhesus monkeys. The limit of detection, at a signal-to-noise ratio of 5, was 0.2 fg/mL EE spiked into blank plasma. This allowed for a lower limit of quantitation of 5 pg/mL using a 50-muL plasma sample and 10-muL injection of dansylated derivative into the CTC-PAL Leap autosampler coupled to a Sciex API 4000 mass spectrometer. Using fast-gradient liquid chromatography, the analyte peak eluted at 1.6 min. The validation results showed high accuracy (% bias < 4) and precision (% CV < 7.5) at broad linear dynamic ranges (0.005-20 ng/mL), using deuterated EE as internal standard. Therefore, the facile dansyl derivatization coupled with tandem mass spectral analysis allowed the development of a highly sensitive and specific method for quantitation of trace levels of EE in the plasma of rhesus monkeys dosed orally and intravenously with EE.
引用
收藏
页码:4136 / 4144
页数:9
相关论文
共 47 条
[1]   DEVELOPMENT OF A RADIOIMMUNOASSAY METHOD FOR ETHYNYLESTRADIOL IN PLASMA USING A MONOCLONAL-ANTIBODY [J].
AGASAN, AL ;
STEWART, BJ ;
WATSON, TG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 177 (1-2) :251-260
[2]   DEVELOPMENT OF A MONOCLONAL-ANTIBODY FOR USE IN RADIOIMMUNOASSAY OF ETHYNYLESTRADIOL [J].
AGASAN, AL ;
BRIGGS, MH ;
HEWISH, DR ;
STEWART, B .
STEROIDS, 1986, 47 (4-5) :295-306
[3]   THE INTERACTION OF PHENOBARBITAL AND OTHER ANTICONVULSANTS WITH ORAL-CONTRACEPTIVE STEROID-THERAPY [J].
BACK, DJ ;
BATES, M ;
BOWDEN, A ;
BRECKENRIDGE, AM ;
HALL, MJ ;
JONES, H ;
MACIVER, M ;
ORME, M ;
PERUCCA, E ;
RICHENS, A ;
ROWE, PH ;
SMITH, E .
CONTRACEPTION, 1980, 22 (05) :495-503
[4]   INVESTIGATION OF THE PHARMACOKINETICS OF ETHYNYLESTRADIOL IN WOMEN USING RADIOIMMUNOASSAY [J].
BACK, DJ ;
BRECKENRIDGE, AM ;
CRAWFORD, FE ;
MACIVER, M ;
ORME, MLE ;
ROWE, PH ;
WATTS, MJ .
CONTRACEPTION, 1979, 20 (03) :263-273
[5]   EFFECT OF RIFAMPICIN ON THE PHARMACOKINETICS OF ETHYNYLESTRADIOL IN WOMEN [J].
BACK, DJ ;
BRECKENRIDGE, AM ;
CRAWFORD, FE ;
HALL, JM ;
MACIVER, M ;
ORME, MLE ;
ROWE, PH ;
SMITH, E ;
WATTS, MJ .
CONTRACEPTION, 1980, 21 (02) :135-143
[6]   EVALUATION OF COMMITTEE ON SAFETY OF MEDICINES YELLOW CARD REPORTS ON ORAL CONTRACEPTIVE DRUG INTERACTIONS WITH ANTI-CONVULSANTS AND ANTIBIOTICS [J].
BACK, DJ ;
GRIMMER, SFM ;
ORME, MLE ;
PROUDLOVE, C ;
MANN, RD ;
BRECKENRIDGE, AM .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1988, 25 (05) :527-532
[7]   PHARMACOKINETIC DRUG-INTERACTIONS WITH ORAL-CONTRACEPTIVES [J].
BACK, DJ ;
ORME, MLE .
CLINICAL PHARMACOKINETICS, 1990, 18 (06) :472-484
[8]   INTERINDIVIDUAL VARIATION AND DRUG-INTERACTIONS WITH HORMONAL STEROID-CONTRACEPTIVES [J].
BACK, DJ ;
BRECKENRIDGE, AM ;
CRAWFORD, FE ;
MACIVER, M ;
ORME, MLE ;
ROWE, PH .
DRUGS, 1981, 21 (01) :46-61
[10]  
COLE, 1997, ELECTROSPRAY IONIZAT