Reduced Patient Radiation Exposure during Neurodiagnostic and Interventional X-Ray Angiography with a New Imaging Platform

被引:9
作者
van der Marel, K. [1 ]
Vedantham, S. [1 ]
van der Bom, I. M. J. [2 ]
Howk, M. [1 ]
Narain, T. [1 ]
Ty, K. [1 ]
Karellas, A. [1 ]
Gounis, M. J. [1 ]
Puri, A. S. [1 ]
Wakhloo, A. K. [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, New England Ctr Stroke Res, Worcester, MA USA
[2] Philips Healthcare, Best, Netherlands
关键词
NOISE-REDUCTION TECHNOLOGY; SKIN; RADIOLOGY; NEURORADIOLOGY; QUALITY;
D O I
10.3174/ajnr.A5049
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Advancements in medical device and imaging technology as well as accruing clinical evidence have accelerated the growth of the endovascular treatment of cerebrovascular diseases. However, the augmented role of these procedures raises concerns about the radiation dose to patients and operators. We evaluated patient doses from an x-ray imaging platform with radiation dose-reduction technology, which combined image noise reduction, motion correction, and contrast-dependent temporal averaging with optimized x-ray exposure settings. MATERIALS AND METHODS: In this single-center, retrospective study, cumulative dose-area product inclusive of fluoroscopy, angiography, and 3D acquisitions for all neurovascular procedures performed during a 2-year period on the dose-reduction platform were compared with a reference platform. Key study features were the following: The neurointerventional radiologist could select the targeted dose reduction for each patient with the dose-reduction platform, and the statistical analyses included patient characteristics and the neurointerventional radiologist as covariates. The analyzed outcome measures were cumulative dose (kerma)-area product, fluoroscopy duration, and administered contrast volume. RESULTS: A total of 1238 neurointerventional cases were included, of which 914 and 324 were performed on the reference and dose-reduction platforms, respectively. Over all diagnostic and neurointerventional procedures, the cumulative dose-area product was significantly reduced by 53.2% (mean reduction, 160.3 Gy x cm(2); P < .0001), fluoroscopy duration was marginally significantly increased (mean increase, 5.2 minutes; P = .0491), and contrast volume was nonsignificantly increased (mean increase, 15.3 mL; P = .1616) with the dose-reduction platform. CONCLUSIONS: A significant reduction in patient radiation dose is achievable during neurovascular procedures by using dose-reduction technology with a minimal impact on workflow.
引用
收藏
页码:442 / 449
页数:8
相关论文
共 30 条
  • [21] Image Gently, Step Lightly: Promoting Radiation Safety in Pediatric Interventional Radiology
    Sidhu, Manrita
    Goske, Marilyn J.
    Connolly, Bairbre
    Racadio, John
    Yoshizumi, Terry T.
    Strauss, Keith J.
    Coley, Brian D.
    Utley, Tara
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) : W299 - W301
  • [22] Image Noise Reduction Algorithm for Digital Subtraction Angiography: Clinical Results
    Soderman, Michael
    Holmin, Staffan
    Andersson, Tommy
    Palmgren, Charlotta
    Babic, Drazenko
    Hoornaert, Bart
    [J]. RADIOLOGY, 2013, 269 (02) : 553 - 560
  • [23] Radiation dose in neuroangiography using image noise reduction technology: a population study based on 614 patients
    Soderman, Michael
    Mauti, Maria
    Boon, Sjirk
    Omar, Artur
    Marteinsdottir, Maria
    Andersson, Tommy
    Holmin, Staffan
    Hoornaert, Bart
    [J]. NEURORADIOLOGY, 2013, 55 (11) : 1365 - 1372
  • [24] Guidelines for Patient Radiation Dose Management
    Stecker, Michael S.
    Balter, Stephen
    Towbin, Richard B.
    Miller, Donald L.
    Vano, Eliseo
    Bartal, Gabriel
    Angle, J. Fritz
    Chao, Christine P.
    Cohen, Alan M.
    Dixon, Robert G.
    Gross, Kathleen
    Hartnell, George G.
    Schueler, Beth
    Statler, John D.
    de Baere, Thierry
    Cardella, John F.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (07) : S263 - S273
  • [25] Novel X-ray image noise reduction technology reduces patient radiation dose while maintaining image quality in coronary angiography
    ten Cate, T.
    van Wely, M.
    Gehlmann, H.
    Mauti, M.
    Camaro, C.
    Reifart, N.
    Suryapranata, H.
    de Boer, M. J.
    [J]. NETHERLANDS HEART JOURNAL, 2015, 23 (11) : 525 - 530
  • [26] Significant Radiation Dose Reduction in the Hybrid Operating Room Using a Novel X-ray Imaging Technology
    van den Haak, R. F. F.
    Hamans, B. C.
    Zuurmond, K.
    Verhoeven, B. A. N.
    Koning, O. H. J.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (04) : 480 - 486
  • [27] Evaluation of a Noise Reduction Imaging Technology in Iliac Digital Subtraction Angiography: Noninferior Clinical Image Quality with Lower Patient and Scatter Dose
    van Strijen, Marco J.
    Grunhagen, Thijs
    Mauti, Maria
    Zaehringer, Markus
    Gaines, Peter A.
    Robinson, Graham J.
    Railton, Nicholas J.
    van Overhagen, Hans
    Habraken, Jan
    van Leersum, Marc
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (05) : 642 - 650
  • [28] Patient dose in interventional radiology:: A European survey
    Vano, E.
    Jarvinen, H.
    Kosunen, A.
    Bly, R.
    Malone, J.
    Dowling, A.
    Larkin, A.
    Padovani, R.
    Bosmans, H.
    Dragusin, O.
    Jaschke, W.
    Torbica, P.
    Back, C.
    Schreiner, A.
    Bokou, C.
    Kottou, S.
    Tsapaki, V.
    Jankowski, J.
    Papierz, S.
    Domienik, J.
    Werduch, A.
    Nikodemova, D.
    Salat, D.
    Kepler, K.
    Bor, M. D.
    Vassileva, J.
    Borisova, R.
    Pellet, S.
    Corbett, R. H.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 39 - 45
  • [29] Patient Radiation Dose Management in the Follow-Up of Potential Skin Injuries in Neuroradiology
    Vano, E.
    Fernandez, J. M.
    Sanchez, R. M.
    Martinez, D.
    Lopez Ibor, L.
    Gil, A.
    Serna-Candel, C.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (02) : 277 - 282
  • [30] Velat GJ, 2008, NEUROSURGERY, V63, P73, DOI [10.1227/01.NEU.0000320136.05677.91, 10.1227/01.neu.0000335015.83616.12]