A novel isatin-based probe for ratiometric and selective detection of Hg2+ and Cu2+ ions present in aqueous and environmental samples

被引:23
作者
Divya, D. [1 ]
Thennarasu, S. [1 ]
机构
[1] CSIR Cent Leather Res Inst, Organ & Bioorgan Chem Lab, Chennai 600020, Tamil Nadu, India
关键词
Isatin derivative; Hydrazinopyridine; UV-Vis spectroscopy; Chemosensor; Naked-eye detection; Ratiometric quantitation; Binding isotherm; COPPER(II) COMPLEXES; FLUORESCENT SENSORS; MERCURY LEVELS; WATER SAMPLES; URIC-ACID; TURN-ON; CHEMOSENSOR; COORDINATION; CU(II); ZINC;
D O I
10.1016/j.saa.2020.118796
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A novel isatin derivative (1) is UV-Visible active and displays about 90 nm bathochromic shift upon interaction with only Hg2+ and Cu2+, but not with other common metal ions. Also, the colorless probe 1 turns to brick-red and yellow in the presence of Hg2+ and Cu2+, respectively. Addition of increasing amounts of Hg2+ or Cu2+ to 1 leads to the emergence of a new absorption at similar to 470 nm (due to LMCT), with a concomitant decrease in the intensity of absorption of 1 at similar to 380 nm, and thereby provides a ratiometric response. Common metal ions and anions do not interfere with the interactions of 1 with Hg2+ or Cu2+ ions. Probe 1 shows very high sensitivity and selectivity towards Hg2+ and Cu2+ as revealed by their very low detection limits 0.95 x 10(-9) M and 1.5 x 10(-9) M, respectively. Formation of 1:1 complex with Hg2+ and 2:1 complex with Cu2+ is confirmed using NMR, ESI-MS and FT-IR techniques, Job plot and DFT calculations. Selective detection of Hg2+ from Cu2+ is established from the ratiometric response caused by beta-mercaptoethanol. Advantages of the probe 1 in terms of high sensitivity, stability in the physiological pH and suitability for dual detection are presented. Probe impregnated silica plates for onsite detection of Hg2+ and Cu2+ present in environmental samples is also demonstrated. (C) 2020 Published by Elsevier B.V.
引用
收藏
页数:11
相关论文
共 67 条
[11]   Synthetic fluorescent sensors for studying the cell biology of metals [J].
Domaille, Dylan W. ;
Que, Emily L. ;
Chang, Christopher J. .
NATURE CHEMICAL BIOLOGY, 2008, 4 (03) :168-175
[12]  
Flanagan Daniel M., 2018, COPPER
[13]   Copper homeostasis and neurodegenerative disorders (Alzheimer's, prion, and Parkinson's diseases and amyotrophic lateral sclerosis) [J].
Gaggelli, Elena ;
Kozlowski, Henryk ;
Valensin, Daniela ;
Valensin, Gianni .
CHEMICAL REVIEWS, 2006, 106 (06) :1995-2044
[14]   Anion receptors based on organic frameworks:: highlights from 2005 and 2006 [J].
Gale, Philip A. ;
Garcia-Garrido, Sergio E. ;
Garric, Joachim .
CHEMICAL SOCIETY REVIEWS, 2008, 37 (01) :151-190
[15]   A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone, abused for doping [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Chatterjee, Sanghamitra .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3562-3568
[16]   Fullerene-C60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Chatterjee, Sanghamitra .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1649-1654
[17]   Voltammetric determination of uric acid at a fullerene-C60-modified glassy carbon electrode [J].
Goyal, RN ;
Gupta, VK ;
Sangal, A ;
Bachheti, N .
ELECTROANALYSIS, 2005, 17 (24) :2217-2223
[18]   Cognitive performance of children prenatally exposed to "safe" levels of methylmercury [J].
Grandjean, P ;
Weihe, P ;
White, RF ;
Debes, F .
ENVIRONMENTAL RESEARCH, 1998, 77 (02) :165-172
[19]   Highly selective colorimetric naked-eye Cu(II) detection using an azobenzene chemosensor [J].
Gunnlaugsson, T ;
Leonard, JP ;
Murray, NS .
ORGANIC LETTERS, 2004, 6 (10) :1557-1560
[20]   Electrochemical Analysis of Some Toxic Metals by Ion-Selective Electrodes [J].
Gupta, Vinod K. ;
Ganjali, M. R. ;
Norouzi, P. ;
Khani, H. ;
Nayak, Arunima ;
Agarwal, Shilpi .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2011, 41 (04) :282-313