Real-Time Measurement of Single Bacterium's Refractive Index using Optofluidic Immersion Refractometry

被引:47
作者
Liu, P. Y. [1 ,2 ]
Chin, L. K. [2 ]
Ser, W. [2 ]
Ayi, T. C. [3 ]
Yap, P. H. [3 ]
Bourouina, T. [1 ]
Leprince-Wang, Y. [1 ]
机构
[1] Univ Paris Est, UPEM, F-77454 Marne La Vallee, France
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[3] Def Med & Environm Inst, DSO Natl Labs, Singapore 117510, Singapore
来源
28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014) | 2014年 / 87卷
关键词
Optofludics; immersion refractometer; waterborne bacteria; LIVING CELLS; WATER;
D O I
10.1016/j.proeng.2014.11.743
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper presents a biophysical method to characterize single bacterium in water by using an on-chip optofluidic immersion refractometer. Water safety is a major factor in the well-being of people, but the presence of bacteria such as Escherichia coli (E. coli), bacillus subtilis, Shigella flexneri and vibrio cholera in drinking water can lead to infectious diseases such as typhoid fever. Hence, it is crucial to detect and identify bacteria to prevent bacterial outbreaks. In this paper, an optofluidic immersion refractometer is developed to measure three biophysical parameters, i.e. size, shape and refractive index. The refractive index of a single bacterium is measured in high sensitivity of 0.005 RIU. This system is an innovative method to allow on-site real-time detection of single bacterium in water. It significantly reduces the amount of detection time and do not require trained personnel or additional chemical and biological reagents. (C) 2014 Published by Elsevier Ltd.
引用
收藏
页码:356 / 359
页数:4
相关论文
共 12 条
[1]  
[Anonymous], 2002, Guidelines for drinking- water quality, VSecond
[2]  
BARER R, 1955, Q J MICROSC SCI, V96, P1
[3]  
Barer R., NATURE, P720
[4]  
Long Sharon C., 2006, Journal of Water and Health, V4, P277, DOI 10.2166/wh.2006.016
[5]  
Doyle M., 2006, FRI BRIEFINGS
[6]   Two-beam optical traps: Refractive index and size measurements of microscale objects [J].
Flynn, RA ;
Shao, B ;
Chachisvilis, M ;
Ozkan, M ;
Esener, SC .
BIOMEDICAL MICRODEVICES, 2005, 7 (02) :93-97
[7]   Method for rapid detection of viable Escherichia coli in water using real-time NASBA [J].
Heijnen, Leo ;
Medema, Gertjan .
WATER RESEARCH, 2009, 43 (12) :3124-3132
[8]   Single live cell refractometer using nanoparticle coated fiber tip [J].
Lee, Jung-Yan ;
Lee, Chia-Wei ;
Lin, En-Hong ;
Wei, Pei-Kuen .
APPLIED PHYSICS LETTERS, 2008, 93 (17)
[9]   On-line bacteriological detection in water [J].
Lopez-Roldan, Ramon ;
Tusell, Pol ;
Courtois, Sophie ;
Luis Cortina, Jose .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 44 :46-57
[10]   Measurement of the integral refractive index and dynamic cell morphometry of living cells with digital holographic microscopy [J].
Rappaz, B ;
Marquet, P ;
Cuche, E ;
Emery, Y ;
Depeursinge, C ;
Magistretti, PJ .
OPTICS EXPRESS, 2005, 13 (23) :9361-9373