Fast Transistor Open-Circuit Faults Diagnosis in Grid-Tied Three-Phase VSIs Based on Average Bridge Arm Pole-to-Pole Voltages and Error-Adaptive Thresholds

被引:84
|
作者
Li, Zhan [1 ]
Ma, Hao [1 ]
Bai, Zhihong [1 ]
Wang, Yuxi [2 ]
Wang, Borong [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Inst Power Elect, Hangzhou 310027, Zhejiang, Peoples R China
[2] Delta Elect Co Ltd, Hangzhou 310008, Zhejiang, Peoples R China
关键词
Average bridge arm pole-to-pole (PTP) voltages; error-adaptive thresholds; fault diagnosis; grid-tied three-phase voltage-source inverters (VSI); transistor open-circuit (OC) fault; OPEN-SWITCH FAULTS; SOURCE INVERTERS; PATTERN-RECOGNITION; NEURAL-NETWORK; DRIVE SYSTEMS; MOTOR-DRIVES; VECTOR; CONVERTERS; ALGORITHM; MODEL;
D O I
10.1109/TPEL.2017.2773130
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a model-based method to diagnose single-and multiple-transistor open-circuit (OC) faults in grid-tied three-phase voltage-source inverters (VSIs). The method is based on calculated average bridge arm pole-to-pole (PTP) voltages and error-adaptive thresholds. Only existing signals for closed-loop control are needed; thus, this method can be easily embedded in the system without extra sampling and circuits. Average PTP voltage deviations are chosen as diagnosis variables, which show considerable distinction quickly after fault. Consequently, fast fault diagnosis speed can be achieved. The fault diagnosis time for single fault can be as short as two switching periods. Besides, diagnosis variables show the same faulty characteristics in inverter mode and rectifier mode; thus, this method is effective in both modes. Moreover, for the first time, the variation of inductance caused by conducted current is considered to obtain a more accurate variable-inductance model, and the thresholds are updated according to mathematically estimated diagnosis variable calculation errors from sampling error, inductance error, dead time, and delay time, which maintains high robustness as well as fast speed. Finally, the effectiveness of the proposed method is validated with experiments.
引用
收藏
页码:8040 / 8051
页数:12
相关论文
共 3 条
  • [1] Fast Open-Transistor Fault Diagnosis Based on Calculated Bridge Arm Pole-to-Pole Voltages in Voltage-Source Inverters
    Li, Zhan
    Bai, Zhihong
    Ma, Hao
    Wang, Yuxi
    2016 IEEE 2ND ANNUAL SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2016,
  • [2] An Average Model-Based Transistor Open-Circuit Fault Diagnosis Method for Grid-Tied Single-Phase Inverter
    Li, Zhan
    Wang, Borong
    Ren, Yini
    Wang, Jun
    Bai, Zhihong
    Ma, Hao
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 993 - 998
  • [3] L- and LCL-Filtered Grid-Tied Single-Phase Inverter Transistor Open-Circuit Fault Diagnosis Based on Post-Fault Reconfiguration Algorithms
    Li, Zhan
    Wang, Borong
    Ren, Yini
    Wang, Jun
    Bai, Zhihong
    Ma, Hao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (10) : 10180 - 10192