Various single particle measuring techniques are briefly reviewed and the basic concepts of a new microsuperconducting quantum interference device technique are discussed. It allows measurements of the magnetization reversal of single nanometer-sized particles at low temperature. The influence of the measuring technique on the system of interest is discussed. (C) 2000 American Institute of Physics. [S0021-8979(00)36608-7].