Enhanced coyote optimizer-based cascaded load frequency controllers in multi-area power systems with renewable

被引:43
作者
Abou El-Ela, Adel A. [1 ]
El-Sehiemy, Ragab A. [2 ]
Shaheen, Abdullah M. [3 ]
Diab, Abd El-Gelil [4 ]
机构
[1] Menoufiya Univ, Fac Engn, Elect Engn Dept, Shibin Al Kawm, Egypt
[2] Kafrelsheikh Univ, Fac Engn, Elect Engn Dept, Kafrelsheikh, Egypt
[3] Suez Univ, Fac Engn, Elect Engn Dept, Suez, Egypt
[4] Middle Delta Elect Prod Co, MDEPC, Minist Elect & Renewable Energy, El Buhayira, Egypt
关键词
Enhanced coyote optimizer; Load frequency control; Multi-area power system; Photovoltaic panel; Cascaded controller; Uncertainty; AUTOMATIC-GENERATION CONTROL; PID CONTROLLER; ALGORITHM; LFC; AGC;
D O I
10.1007/s00521-020-05599-8
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Recently, the renewable energy has been occupied a lot of attention around the world since it presents cheap and sustainable energy. Consequently, its presence in power systems becomes a fact that had to deal with. Hence, load frequency control (LFC) in multi-area power systems that constitute photovoltaic (PV) and thermal plant sources is proposed. Two forms of competing cascaded controllers, namely proportional integral-proportional integral (PI-PI) and proportional-derivative with filter-PI (PDn-PI), are investigated, and their performances are compared with traditional PI and PIDn controller. An enhanced coyote optimization algorithm (ECOA) is proposed for finding the optimal tuned parameters of the proposed controllers. Furthermore, the uncertainty is considered under the variation of system parameters by +/- 40%. The performance of the proposed competing controllers is tested under dynamic load change that is applied individually in each area. These controllers are applied on two dissimilar test cases with various sets of disturbances. The obtained results are compared with various reported techniques. The simulated comparisons declare the great efficiency with high superiority robustness of the proposed cascaded PDn-PI based on ECOA for handling the LFC in multi-area power systems.
引用
收藏
页码:8459 / 8477
页数:19
相关论文
共 36 条
[11]   Automatic generation control using two degree of freedom fractional order PID controller [J].
Debbarma, Sanjoy ;
Saikia, Lalit Chandra ;
Sinha, Nidul .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 58 :120-129
[12]   Recent Coyote Algorithm-Based Energy Management Strategy for Enhancing Fuel Economy of Hybrid FC/Battery/SC System [J].
Fathy, Ahmed ;
Al-Dhaifallah, Mujahed ;
Rezk, Hegazy .
IEEE ACCESS, 2019, 7 :179409-179419
[13]  
Güvenç U, 2019, 2019 7TH INTERNATIONAL ISTANBUL SMART GRIDS AND CITIES CONGRESS AND FAIR (ICSG ISTANBUL 2019), P179, DOI 10.1109/SGCF.2019.8782354
[14]  
Khadanga RK, 2019, NEURAL COMPUT APPL, V32, P1
[15]   Recent philosophies of automatic generation control strategies in power systems [J].
Kumar, LP ;
Kothari, DP .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (01) :346-357
[16]   LFC for multi-area interconnected power system concerning wind turbines based on DMPC [J].
Ma, Miaomiao ;
Liu, Xiangjie ;
Zhang, Chunyu .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (10) :2689-2696
[17]  
Mohapatra T, 2020, IET GENER TRANSM DIS
[18]   Hybrid BFOA-PSO algorithm for automatic generation control of linear and nonlinear interconnected power systems [J].
Panda, Sidhartha ;
Mohanty, Banaja ;
Hota, P. K. .
APPLIED SOFT COMPUTING, 2013, 13 (12) :4718-4730
[19]   Load frequency control of a realistic power system with multi-source power generation [J].
Parmar, K. P. Singh ;
Majhi, S. ;
Kothari, D. P. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) :426-433
[20]  
Parmar K. S., 2010, 2010 JOINT INT C POW, P1