Contrast enhancement of intracranial lesions at 1.5 T: comparison among 2D spin echo, black-blood (BB) Cube, and BB Cube-FLAIR sequences

被引:4
作者
Im, SungWoon [1 ]
Ashikaga, Ryuichiro [1 ]
Yagyu, Yukinobu [1 ]
Wakayama, Tetsuya [2 ]
Miyoshi, Mitsuharu [2 ]
Hyodo, Tomoko [1 ]
Imaoka, Izumi [1 ]
Kumano, Seishi [1 ]
Ishii, Kazunari [1 ]
Murakami, Takamichi [1 ]
机构
[1] Kinki Univ, Fac Med, Dept Radiol, Osaka, Osaka 5898511, Japan
[2] GE Healthcare Japan, MR Applicat & Workflow, Hino, Tokyo 1918503, Japan
关键词
Cube; 3Dfast spin-echo(FSE); black-blood(BB) imaging; Contrast enhancement; Magnetic resonance imaging; BRAIN;
D O I
10.1007/s00330-015-3757-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the usefulness of T1W black-blood Cube (BB Cube) and T1W BB Cube fluid-attenuated inversion recovery (BB Cube-FLAIR) sequences for contrast-enhanced brain imaging, by evaluating flow-related artefacts, detectability, and contrast ratio (CR) of intracranial lesions among these sequences and T1W-SE. Phantom studies were performed to determine the optimal parameters of BB Cube and BB Cube-FLAIR. A clinical study in 23 patients with intracranial lesions was performed to evaluate the usefulness of these two sequences for the diagnosis of intracranial lesions compared with the conventional 2D T1W-SE sequence. The phantom study revealed that the optimal parameters for contrast-enhanced T1W imaging were TR/TE = 500 ms/minimum in BB Cube and TR/TE/TI = 600 ms/minimum/300 ms in BB Cube-FLAIR imaging. In the clinical study, the degree of flow-related artefacts was significantly lower in BB Cube and BB Cube-FLAIR than in T1W-SE. Regarding tumour detection, BB Cube showed the best detectability; however, there were no significant differences in CR among the sequences. At 1.5 T, contrast-enhanced BB Cube was a better imaging sequence for detecting brain lesions than T1W-SE or BB Cube-FLAIR. aEuro cent Cube is a single-slab 3D FSE imaging sequence. aEuro cent We applied a black-blood (BB) imaging technique to T1W Cube. aEuro cent At 1.5 T, contrast-enhanced T1W BB Cube was valuable for detecting brain lesions.
引用
收藏
页码:3175 / 3186
页数:12
相关论文
共 12 条
  • [1] MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN
    BRANTZAWADZKI, M
    GILLAN, GD
    NITZ, WR
    [J]. RADIOLOGY, 1992, 182 (03) : 769 - 775
  • [2] CHAPPELL PM, 1994, AM J NEURORADIOL, V15, P37
  • [3] Measuring signal-to-noise ratio in partially parallel imaging MRI
    Goerner, Frank L.
    Clarke, Geoffrey D.
    [J]. MEDICAL PHYSICS, 2011, 38 (09) : 5049 - 5057
  • [4] Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences
    Kakeda, Shingo
    Korogi, Yukunori
    Hiai, Yasuhiro
    Ohnari, Norihiro
    Moriya, Junji
    Kamada, Koji
    Hanamiya, Mai
    Sato, Toru
    Kitajima, Mika
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (09) : 2345 - 2351
  • [5] Komada Tomohiro, 2008, Magn Reson Med Sci, V7, P13, DOI 10.2463/mrms.7.13
  • [6] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [7] Usefulness of optimized gadolinium-enhanced fast fluid-attenuated inversion recovery MR imaging in revealing lesions of the brain
    Melhem, ER
    Bert, RJ
    Walker, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) : 803 - 807
  • [8] Optimized Three-Dimensional Fast-Spin-Echo MRI
    Mugler, John P., III
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 745 - 767
  • [9] Naganawa S, 2008, EUR RADIOL, V18, P337, DOI [10.1007/s00330-007-0741-8, 10.1007/s00330-007-0741-1]
  • [10] Contrast-Enhanced, Three-Dimensional, Whole-Brain, Black-Blood Imaging: Application to Small Brain Metastases