Biomedical nanostructured coating for minimally invasive surgery devices applications: characterization, cell cytotoxicity evaluation and an animal study in rat

被引:38
作者
Ou, Keng-Liang [1 ,2 ,3 ,4 ]
Chu, Jan-Show [2 ,5 ,6 ]
Hosseinkhani, Hossein [7 ]
Chiou, Jeng-Fong [8 ,9 ,10 ]
Yu, Chih-Hua [2 ,3 ]
机构
[1] Taipei Med Univ, Grad Inst Biomed Mat & Tissue Engn, Coll Oral Med, Taipei 110, Taiwan
[2] Taipei Med Univ, Res Ctr Biomed Devices & Prototyping Prod, Taipei 110, Taiwan
[3] Taipei Med Univ, Res Ctr Biomed Implants & Microsurg Devices, Taipei 110, Taiwan
[4] Taipei Med Univ, Shuang Ho Hosp, Dept Dent, Taipei 235, Taiwan
[5] Taipei Med Univ, Coll Med, Grad Inst Clin Med, Taipei 110, Taiwan
[6] Taipei Med Univ, Dept Pathol, Coll Med, Taipei 110, Taiwan
[7] Natl Taiwan Univ Sci & Technol, Grad Inst Biomed Engn, Taipei 106, Taiwan
[8] Taipei Med Univ, Sch Med, Dept Radiat Oncol, Taipei 110, Taiwan
[9] Taipei Med Univ & Hosp, Ctr Canc, Taipei 110, Taiwan
[10] Taipei Med Univ & Hosp, Dept Radiat Oncol, Taipei 110, Taiwan
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2014年 / 28卷 / 07期
关键词
Surface modification; Minimally invasive surgery; Tissue sticking; Thermal injury; Cytotoxicity; In vivo test; NF-KAPPA-B; LIVER-REGENERATION; STAINLESS-STEEL; BIPOLAR FORCEPS; CRN COATINGS; INJURY; ELECTROSURGERY; MOLECULE; FIBROSIS; SMOKE;
D O I
10.1007/s00464-014-3450-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Thermal injury and tissue sticking, which influence wound remodeling, are major concerns in electrosurgery. In this study, the effect of lateral thermal injury caused by different electrosurgical electrodes on hepatic remodeling was investigated. A monopolar electrosurgical unit equipped with untreated stainless steel (SS) and chromium nitride coated stainless steel (CrN-SS) electrodes was used to create lesions on the liver lobes of adult rats. Animals were sacrificed for evaluations at 0, 3, 7, and 28 days postoperatively. CrN-SS needles generated lower levels of sticking tissue, and the thermographs showed that recorded highest temperature in liver tissue from the CrN-SS needle group was significantly lower than in the SS needle group. The total injury area of livers treated with CrN-SS needles was significantly lower than livers treated with SS needles at each time point. Moreover, the CrN-SS needles caused a relatively smaller area of lateral thermal injury, a smaller area of fibrotic tissue, and a faster process of hepatic remodeling in rat liver than the SS needles. Immunofluorescence staining and Western blot analysis showed that rats treated with CrN-SS needles expressed lower levels of NF-kappa B and caspase-3 postoperatively. This study reveals that the plating of electrodes with a CrN film is an efficient method for improving the performance of electrosurgical units and should benefit wound remodeling. However, more tests must be performed to confirm these promising findings in human patients.
引用
收藏
页码:2174 / 2188
页数:15
相关论文
共 40 条
  • [1] Chemical composition of smoke produced by high-frequency electrosurgery
    Al Sahaf, O. S.
    Vega-Carrascal, I.
    Cunningham, F. O.
    McGrath, J. P.
    Bloomfield, F. J.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2007, 176 (03) : 229 - 232
  • [2] A critical role for matrix metal loproteinases in liver regeneration
    Alwayn, Ian P. J.
    Verbesey, Jennifer E.
    Kim, Sendia
    Roy, Roopali
    Arsenault, Danielle A.
    Greene, Arin K.
    Novak, Katherine
    Laforme, Andrea
    Lee, Sang
    Moses, Marsha A.
    Puder, Mark
    [J]. JOURNAL OF SURGICAL RESEARCH, 2008, 145 (02) : 192 - 198
  • [3] A comparative study of reactive direct current magnetron sputtered CrAlN and CrN coatings
    Barshilia, Harish C.
    Selvakumar, N.
    Deepthi, B.
    Rajam, K. S.
    [J]. SURFACE & COATINGS TECHNOLOGY, 2006, 201 (06) : 2193 - 2201
  • [4] Bipolar electrosurgery: Convention and innovation
    Brill, Andrew I.
    [J]. CLINICAL OBSTETRICS AND GYNECOLOGY, 2008, 51 (01) : 153 - 158
  • [5] Concepts, considerations, and concerns on the cutting edge of radiofrequency ablation
    Brown, DB
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (05) : 597 - 613
  • [6] A new coated bipolar coagulator: Technical note
    Ceviker, N
    Keskil, S
    Baykaner, K
    [J]. ACTA NEUROCHIRURGICA, 1998, 140 (06) : 619 - 620
  • [7] The influence of Cr-based coating on the adhesion force between epoxy molding compounds and IC encapsulation mold
    Chiu, S. M.
    Hwang, S. J.
    Chu, C. W.
    Gan, Dershin
    [J]. THIN SOLID FILMS, 2006, 515 (01) : 285 - 292
  • [8] Chowdhury K K, 2011, Mymensingh Med J, V20, P507
  • [9] Surface analysis of electrochemically stripped CrN coatings
    Conde, A.
    Cristobal, A. B.
    Fuentes, G.
    Tate, T.
    de Damborenea, J.
    [J]. SURFACE & COATINGS TECHNOLOGY, 2006, 201 (06) : 3588 - 3595
  • [10] Dodde R., 2010, Journal of Medical Devices [Internet], DOI DOI 10.1115/1.3439653