Application of an amine-based CO2 capture system in retrofitting combined gas-steam power plants

被引:13
作者
Carapellucci, Roberto [1 ]
Giordano, Lorena [1 ]
Vaccarelli, Maura [1 ]
机构
[1] Univ Aquila, Dept Ind & Informat Engn & Econ, Via G Gronchi 18, I-67100 Laquila, Italy
关键词
NGCCs; Auxiliary system; Derating Efficiency penalty; COE increase; CARBON CAPTURE; PERFORMANCE; ENERGY; TECHNOLOGIES; ABSORPTION;
D O I
10.1016/j.energy.2016.10.114
中图分类号
O414.1 [热力学];
学科分类号
摘要
Natural gas combined cycles (NGCCs) represent the main power generation technology in Italy, with a share of more than 40% of global thermoelectric power production. Due to their high operational flexibility, it is likely that NGCCs will continue to play a very important role in maintaining the reliability of supply in a power generation infrastructure characterized by the increasing spread of renewable energies. In this context, the integration of carbon capture technologies is regarded as an essential step to cope with the long-term climate protection target set by the European Union. This study investigates the retrofitting of three Italian NGCCs with a chemical absorption unit, capturing 90% of the CO2 from the exhaust flue gases. Two main options to meet the heat requirement for solvent regeneration are explored. The first provides for a medium-low pressure steam extraction, representing the main reason for power plant capacity derating. In the second option, steam extraction is partially replaced by external steam production from an auxiliary combined heat and power (CHP) unit that is designed to compensate for the additional power requirement of the CO2 separation and compression system equipment. Depending on the size and complexity of the NGCC, several types of auxiliary system are envisaged, basically differing in terms of the cogeneration technology and degree of integration inside the power block. Simulation results highlighted that the integration of an auxiliary cogeneration unit, besides eliminating power plant derating, has the potential to improve the energy and economic performances of the retrofitted plants to a certain extent. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:808 / 826
页数:19
相关论文
共 47 条
[1]  
A2A Energia, 2014, ENV DECLARATION OF G
[2]   CO2 capture from power plants -: Part II.: A parametric study of the economical performance based on mono-ethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (02) :135-142
[3]   A techno-economic analysis of post-combustion CO2 capture and compression applied to a combined cycle gas turbine: Part I. A parametric study of the key technical performance indicators [J].
Alhajaj, Ahmed ;
Mac Dowell, Niall ;
Shah, Nilay .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2016, 44 :26-41
[4]  
Alstom Power, GT 26 GAS TURBINE TE
[5]   Optimized process configurations of post-combustion CO2 capture for natural-gas-fired power plant - Power plant efficiency analysis [J].
Amrollahi, Zeinab ;
Ystad, Paul Andreas Marchioro ;
Ertesvag, Ivar S. ;
Bolland, Olav .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 8 :1-11
[6]  
[Anonymous], 2013, International Energy Outlook 2013
[7]  
[Anonymous], 2014, Key World Energy Statistcs
[8]  
[Anonymous], 2013, STAT DATA OF ELECTRI
[9]  
Balling Lothar., 2010, Modern Power Systems, P61
[10]  
Bellona Foundation, 2009, MAPPING CCS IN ITALY