Endovascular Repair of the Descending Aorta and the Aortic Arch With the Relay Stent Graft

被引:17
作者
Funovics, Martin [1 ]
Blum, Melanie [1 ]
Langenberger, Herbert [1 ]
Plank, Christina [1 ]
Schoder, Maria [1 ]
Edelhauser, Gundula [1 ]
Gottardi, Roman [1 ]
Berzacky, Dominik [1 ]
Dorfmeister, Marion [1 ]
Grimm, Michael [1 ]
Lammer, Johannes [1 ]
Czerny, Martin [1 ]
机构
[1] Med Univ Vienna, Dept Cardiothorac Surg, A-1090 Vienna, Austria
关键词
PLACEMENT; PATHOLOGIES;
D O I
10.1016/j.athoracsur.2008.12.078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. The aim of this study was to evaluate the efficacy and safety of thoracic endovascular aortic repair with a newly designed Relay thoracic stent graft (Bolton Medical, Sunrise, FL). Description. Between 2005 and 2007, 22 patients (71.8 +/- 8.5) received 24 stent grafts. Indications were aneurysms (n = 13), penetrating atherosclerotic ulcers (n = 7), and dissections (n = 2). Due to the proximity of the lesions to the aortic arch, rerouting procedures (ie, subclavian transposition [ n = 1], double transposition [ n = 12], and total arch rerouting [ n = 6] were performed pre-interventionally; three patients did not undergo rerouting). All patients were followed-up with a computed tomographic scan of the entire aorta at discharge, 3 months, 6 months, and annually thereafter (mean follow-up, 13 months). Evaluation. Primary technical success was obtained in 20 of 22 patients, with one persisting type I endoleak and one asymptomatic type II endoleak. One patient died due to malignant arrhythmia 3 days after stent-graft placement. During follow-up, 1 nonaortic related death was observed. No additional endoleaks were observed. Finally, all supraaortic rerouting procedures remained patent. Conclusions. In the treatment of degenerative disease of the descending aorta and the aortic arch, the Bolton Relay stent graft offers acceptable efficacy and safety in short-term follow-up. (Ann Thorac Surg 2009; 88: 637-40) (C) 2009 by The Society of Thoracic Surgeons
引用
收藏
页码:637 / 640
页数:4
相关论文
共 50 条
[11]   Endovascular repair by customized branched stent-graft: A promising treatment for chronic aortic dissection involving the arch branches [J].
Lu, Qingsheng ;
Feng, Jiaxuan ;
Zhou, Jian ;
Zhao, Zhiqing ;
Li, Haiyan ;
Teng, Zhongzhao ;
Jing, Zaiping .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (06) :1631-+
[12]   Endovascular deployment of stent graft in the ascending aorta [J].
Geiger-Gritsch, S. ;
Piso, B. ;
Guba, B. ;
Felder-Puig, R. .
CHIRURG, 2009, 80 (07) :634-640
[13]   Outcomes of Antegrade Stent Graft Deployment During Hybrid Aortic Arch Repair [J].
Aalaei-Andabili, Seyed Hossein ;
Scali, Salvatore ;
Klodell, Charles ;
Lee, Teng ;
Hess, Philip ;
Martin, Tomas ;
Beck, Adam ;
Feezor, Robert ;
Alhussaini, Mahmoud ;
Arnaoutakis, George ;
Beaver, Thomas .
ANNALS OF THORACIC SURGERY, 2017, 104 (02) :538-544
[14]   Two autopsy cases of rupture of the aorta by fistula formation after thoracic endovascular aortic repair and open stent-grafting on aortic arch aneurysm [J].
Mori, Shinjiro ;
Kimura, Satoko ;
Ro, Ayako ;
Hayakawa, Akira ;
Funakoshi, Izumi ;
Fukunaga, Tatsushige ;
Mizukami, Hajime .
CARDIOVASCULAR PATHOLOGY, 2019, 39 :61-66
[15]   The impact of stent graft evolution on the results of endovascular abdominal aortic aneurysm repair [J].
Tadros, Rami O. ;
Faries, Peter L. ;
Ellozy, Sharif H. ;
Lookstein, Robert A. ;
Vouyouka, Ageliki G. ;
Schrier, Rachel ;
Kim, Jamie ;
Marin, Michael L. .
JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) :1518-1527
[16]   Computational investigation of interaction between stent graft and aorta in retrograde type A dissection after thoracic endovascular aortic repair for type B aortic dissection [J].
Ma, Tao ;
Dong, Zhi Hui ;
Wang, Shengzhang ;
Meng, Zhuang Yuan ;
Chen, Yin Yin ;
Fu, Wei Guo .
JOURNAL OF VASCULAR SURGERY, 2018, 68 (06) :14S-+
[17]   Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch [J].
Leone, Nicola ;
Bartolotti, Luigi A. M. ;
Capitain, Andre N. ;
Migliari, Mattia ;
Silingardi, Roberto ;
Czerny, Martin ;
Rylski, Bartosz ;
Gennai, Stefano .
JOURNAL OF VASCULAR SURGERY, 2024, 79 (05) :997-1005
[18]   Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application [J].
Hauck, Sven R. ;
Kupferthaler, Alexander ;
Stelzmueller, Marlies ;
Eilenberg, Wolf ;
Ehrlich, Marek ;
Neumayer, Christoph ;
Wolf, Florian ;
Loewe, Christian ;
Funovics, Martin A. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (09) :1448-1455
[19]   A New Modular Stent Graft to Reconstruct Aortic Arch [J].
Wei, G. ;
Xin, J. ;
Yang, D. ;
Liu, X. ;
Tai, Y. ;
Zhang, H. ;
Liang, F. ;
Zhang, G. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 37 (05) :560-565
[20]   Results of type II hybrid arch repair with zone 0 stent graft deployment for complex aortic arch pathology [J].
Kent, William D. T. ;
Appoo, Jehangir J. ;
Bavaria, Joseph E. ;
Herget, Eric J. ;
Moeller, Patrick ;
Pochettino, Alberto ;
Wong, Jason K. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (06) :2951-2955