Endovascular Repair of the Descending Aorta and the Aortic Arch With the Relay Stent Graft

被引:17
|
作者
Funovics, Martin [1 ]
Blum, Melanie [1 ]
Langenberger, Herbert [1 ]
Plank, Christina [1 ]
Schoder, Maria [1 ]
Edelhauser, Gundula [1 ]
Gottardi, Roman [1 ]
Berzacky, Dominik [1 ]
Dorfmeister, Marion [1 ]
Grimm, Michael [1 ]
Lammer, Johannes [1 ]
Czerny, Martin [1 ]
机构
[1] Med Univ Vienna, Dept Cardiothorac Surg, A-1090 Vienna, Austria
来源
ANNALS OF THORACIC SURGERY | 2009年 / 88卷 / 02期
关键词
PLACEMENT; PATHOLOGIES;
D O I
10.1016/j.athoracsur.2008.12.078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. The aim of this study was to evaluate the efficacy and safety of thoracic endovascular aortic repair with a newly designed Relay thoracic stent graft (Bolton Medical, Sunrise, FL). Description. Between 2005 and 2007, 22 patients (71.8 +/- 8.5) received 24 stent grafts. Indications were aneurysms (n = 13), penetrating atherosclerotic ulcers (n = 7), and dissections (n = 2). Due to the proximity of the lesions to the aortic arch, rerouting procedures (ie, subclavian transposition [ n = 1], double transposition [ n = 12], and total arch rerouting [ n = 6] were performed pre-interventionally; three patients did not undergo rerouting). All patients were followed-up with a computed tomographic scan of the entire aorta at discharge, 3 months, 6 months, and annually thereafter (mean follow-up, 13 months). Evaluation. Primary technical success was obtained in 20 of 22 patients, with one persisting type I endoleak and one asymptomatic type II endoleak. One patient died due to malignant arrhythmia 3 days after stent-graft placement. During follow-up, 1 nonaortic related death was observed. No additional endoleaks were observed. Finally, all supraaortic rerouting procedures remained patent. Conclusions. In the treatment of degenerative disease of the descending aorta and the aortic arch, the Bolton Relay stent graft offers acceptable efficacy and safety in short-term follow-up. (Ann Thorac Surg 2009; 88: 637-40) (C) 2009 by The Society of Thoracic Surgeons
引用
收藏
页码:637 / 640
页数:4
相关论文
共 50 条
  • [1] Endovascular stent graft repair for aneurysms on the descending thoracic aorta
    Ehrlich, M
    Grabenwoeger, M
    Cartes-Zumelzu, F
    Grimm, M
    Petzl, D
    Lammer, J
    Thurnher, S
    Wolner, E
    Havel, M
    ANNALS OF THORACIC SURGERY, 1998, 66 (01): : 19 - 24
  • [2] Dislocation of a stent-graft into the aortic arch during endovascular repair of a descending thoracic aortic aneurysm
    Augustin, N
    Bauernschmitt, R
    Hausleiter, J
    Lange, R
    ANNALS OF THORACIC SURGERY, 2006, 81 (04): : 1502 - 1505
  • [3] Arch to Descending Aorta Extra-anatomic Aortic Repair for Thoracic Stent Graft Infection
    Gagne-Loranger, Maude
    Dumont, Eric
    Voisine, Pierre
    Mohammadi, Siamak
    Dagenais, Francois
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (01) : 135.e13 - 135.e15
  • [4] Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience
    Criado, FJ
    Clark, NS
    Barnatan, MF
    JOURNAL OF VASCULAR SURGERY, 2002, 36 (06) : 1121 - 1127
  • [5] Endovascular stent-graft repair of descending aortic aneurysm
    Soeparwata, R
    Vestring, T
    Reimer, P
    Etz, C
    Hammel, D
    Schmitt, C
    Scheld, HH
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (02): : 207 - 207
  • [6] Application of an extracorporeal prefenestrated stent graft in endovascular repair of ascending aorta and aortic arch lesions
    Wang, Liang
    Bai, Lei
    Zhang, Yujing
    Liu, Jianglong
    Li, Xiaodong
    VASCULAR, 2021, 29 (03) : 323 - 329
  • [7] Endovascular stent graft repair for aneurysms on the descending thoracic aorta - Discussion
    Miller, DC
    Ehrlich, M
    ANNALS OF THORACIC SURGERY, 1998, 66 (01): : 24 - 25
  • [8] Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience - Discussion
    Hollier, LH
    Criado, FJ
    Brener, BJ
    Jorgensen, J
    Golden, M
    Nath, RL
    JOURNAL OF VASCULAR SURGERY, 2002, 36 (06) : 1127 - 1128
  • [9] Endovascular repair of the aortic arch with the NEXUS Stent Graft System
    San Norberto, Enrique M.
    Cenizo, Noelia
    Flota, Cintia M.
    Vaquero, Carlos
    REC-INTERVENTIONAL CARDIOLOGY, 2022, 4 (01): : 63 - 64
  • [10] Endovascular stent-graft repair for acute type A aortic dissection with an intimal tear in the descending aorta
    Shimono, T
    Kato, N
    Tokui, T
    Onoda, K
    Hirano, T
    Takeda, K
    Yuasa, H
    Yada, I
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (01): : 171 - 173