Iron(III) oxide graphite composite electrodes: Application to the electroanalytical detection of hydrazine and hydrogen peroxide

被引:88
作者
Sljukic, Bijana
Banks, Craig E.
Crossley, Alison
Compton, Richard G.
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Univ Oxford, Dept Mat, Oxford OX1 3PH, England
关键词
iron(III) oxide composite electrode; graphite powder; hydrogen peroxide; hydrazine;
D O I
10.1002/elan.200603605
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Composite electrodes based on iron(III) oxide, Fe2O3, carbon powder and epoxy resin have been prepared and characterized using electrochemical methods and X-ray photoelectron spectroscopy (XPS). Initially composite electrodes were made by mixing micron sized carbon powder surface with iron(III) oxide. However, the voltammetric responses were unsatisfactory. Therefore, a new type of composite electrodes was made using carbon powder modified with iron(III) oxide via a wet impregnation procedure. This technique involves saturation of the carbon powder with iron(III) nitrate followed by thermal treatment at ca. 623 K forming iron(III) oxide on the surface of the carbon powder. Several key parameters such as percentage of carbon powder and iron(III) oxide as well as electrode geometry (electrode length) have been optimized. Composite electrodes show attractive performances for the electrochemical detection of hydrogen peroxide and hydrazine with detection limits of 0.12 mu M and 1.18 mu M respectively. These limits of detection are comparable to the detection limits attained by alternative analytical techniques and are lower than that obtained by other electroanalytical methods.
引用
收藏
页码:1757 / 1762
页数:6
相关论文
共 33 条
[1]   Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[2]   Carbon nanotubes contain metal impurities which are responsible for the "electrocatalysis" seen at some nanotube-modified electrodes [J].
Banks, CE ;
Crossley, A ;
Salter, C ;
Wilkins, SJ ;
Compton, RG .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (16) :2533-2537
[3]   The electroanalytical detection of hydrazine: A comparison of the use of palladium nanoparticles supported on boron-doped diamond and palladium plated BDD microdisc array [J].
Batchelor-McAuley, C ;
Banks, CE ;
Simm, AO ;
Jones, TGJ ;
Compton, RG .
ANALYST, 2006, 131 (01) :106-110
[4]   Enzyme-coated carbon nanotubes as single-molecule biosensors [J].
Besteman, K ;
Lee, JO ;
Wiertz, FGM ;
Heering, HA ;
Dekker, C .
NANO LETTERS, 2003, 3 (06) :727-730
[5]   Determination of hydrogen peroxide using glassy carbon and graphite/polyester composite electrodes modified by vanadium-doped zirconias [J].
Doménech, A ;
Alarcón, J .
ANALYTICA CHIMICA ACTA, 2002, 452 (01) :11-22
[7]   Hydrazine determination in sludge samples by high-performance liquid chromatography [J].
Elias, G ;
Bauer, WF .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (03) :460-464
[8]   Glucose sensors based on glucose-oxidase-containing polypyrrole/aligned carbon nanotube coaxial nanowire electrodes [J].
Gao, M ;
Dai, L ;
Wallace, GG .
SYNTHETIC METALS, 2003, 137 (1-3) :1393-1394
[9]   Integrated metabonomic analysis of the multiorgan effects of hydrazine toxicity in the rat [J].
Garrod, S ;
Bollard, ME ;
Nichollst, AW ;
Connor, SC ;
Connelly, J ;
Nicholson, JK ;
Holmes, E .
CHEMICAL RESEARCH IN TOXICOLOGY, 2005, 18 (02) :115-122
[10]   Experimental optimization of selective hydrazine detection in flow injection analysis using a carbon paste electrode modified with copper porphyrin occluded into zeolite cavity [J].
Guerra, SV ;
Kubota, LT ;
Xavier, CR ;
Nakagaki, S .
ANALYTICAL SCIENCES, 1999, 15 (12) :1231-1234