Associated gastroduodenal artery aneurysm aortic aneurysm: the diagnostic contribution of contrast-enhanced ultrasound in correlation with computed tomography angiography

被引:2
作者
Badea, Radu [1 ]
Chiorean, Liliana [2 ]
Chira, Olimpia [3 ]
Caraiani, Cosmin [2 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Octavian Fodor Inst Gastroenterol & Hepatol, Dept Ultrasonog, Cluj Napoca, Romania
[2] Octavian Fodor Inst Gastroenterol & Hepatol, Dept Radiol & Computed Tomog, Cluj Napoca 400162, Romania
[3] Iuliu Hatieganu Univ Med & Pharm, Octavian Fodor Inst Gastroenterol & Hepatol, Dept Gastroenterol, Cluj Napoca, Romania
关键词
Splanchnic artery aneurysm; Gastroduodenal artery aneurysm; Abdominal aorta aneurysm; Contrast-enhanced ultrasound; Computed tomography angiography; ENDOVASCULAR REPAIR; MANAGEMENT;
D O I
10.1007/s10396-013-0507-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Splanchnic aneurysms are rare conditions, with localization at the level of the gastroduodenal artery being encountered in only 1.5 % of the cases. Due to the high mortality risk, early detection and optimal treatment are required. We stress the importance of ultrasonography as a primary method of detection as well as the role of contrast-enhanced ultrasound in characterization of visceral aneurysms. Due to its noninvasive nature, the examination could be used for follow-up after therapeutic procedures or in cases were a curative intervention is not possible.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 23 条
[1]   Splenic artery aneurysms: Two decades experience at Mayo clinic [J].
Abbas, MA ;
Stone, WM ;
Fowl, RJ ;
Gloviczki, P ;
Oldenburg, WA ;
Pairolero, PC ;
Hallett, JW ;
Bower, TC ;
Panneton, JM ;
Cherry, KJ .
ANNALS OF VASCULAR SURGERY, 2002, 16 (04) :442-449
[2]  
Badea R, 2008, J GASTROINTEST LIVER, V17, P101
[3]   Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts [J].
Bendick, PJ ;
Bove, PG ;
Long, GW ;
Zelenock, GB ;
Brown, OW ;
Shanley, CJ .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (02) :381-385
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Initial experience with endovascular aneurysm repair: Comparison of early results with outcome of conventional open repair [J].
Brewster, DC ;
Geller, SC ;
Kaufman, JA ;
Cambria, RP ;
Gertler, JP ;
LaMuraglia, GM ;
Atamian, S ;
Abbott, WM .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (06) :992-1003
[6]  
BUSUTTIL RW, 1980, SURGERY, V88, P619
[7]   Visceral artery aneurysm rupture [J].
Carr, SC ;
Mahvi, DM ;
Hoch, JR ;
Archer, CW ;
Turnipseed, WD .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (04) :806-811
[8]  
Görich J, 1999, RADIOLOGY, V213, P767
[9]   Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair [J].
Iezzi, Roberto ;
Basilico, Raffaella ;
Giancristofaro, Daniela ;
Pascali, Danilo ;
Cotroneo, Antonio Raffaele ;
Storto, Maria Luigia .
JOURNAL OF VASCULAR SURGERY, 2009, 49 (03) :552-560
[10]  
Makaroun MS, 2001, J VASC SURG, V33, pS39