Thermodynamic modeling and exergy analysis of proton exchange membrane fuel cell power system

被引:50
作者
Liu, Guokun [1 ]
Qin, Yanzhou [1 ]
Yin, Yifan [1 ]
Bian, Xianzu [1 ]
Kuang, Changchun [1 ]
机构
[1] Tianjin Univ, State Key Lab Engines, 135 Yaguan Rd, Tianjin 300350, Peoples R China
基金
中国国家自然科学基金;
关键词
Proton exchange membrane fuel cell; Power system; Thermodynamic model; Exergy analysis; Ecological function; EXERGOECONOMIC ANALYSIS; PERFORMANCE ANALYSIS; HEAT-RECOVERY; FLOW; OPERATION; RECIRCULATION; OPTIMIZATION; COMPRESSOR; EJECTOR; DESIGN;
D O I
10.1016/j.ijhydene.2019.08.203
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The proton exchange membrane (PEM) fuel cell (PEMFC) is equipped with a series of auxiliary components which consume considerable amount of energy. It is necessary to investigate the design and operation of the PEMFC power system for better system performance. In this study, a typical PEMFC power system is developed, and a thermodynamic model of the system is established. Simulation is carried out, and the power distribution of each auxiliary component in the system, the net power and power efficiency of the system are obtained. This power system uses cooling water for preheating inlet gases, and its energy-saving effect is also verified by the simulation. On this basis, the exergy analysis is applied on the system, and the indexes of the system exergy loss, exergy efficiency and ecological function are proposed to evaluate the system performance. The results show that fuel cell stack and heat exchanger are the two components that cause the most exergy loss. Furthermore, the system performance under various stack inlet temperatures and current densities is also analyzed. It is found that the net power, energy efficiency and exergy efficiency of the system reach the maximum when the stack inlet temperature is about 348.15 K. The ecological function is maintained at a high level when the stack inlet temperature is around 338.15 K. Lower current density increases the system ecological function and the power and exergy efficiencies, and also helps decrease the system exergy loss, but it decreases the system net power. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:29799 / 29811
页数:13
相关论文
共 39 条
[11]   Life cycle assessment of a polymer electrolyte membrane fuel cell system for passenger vehicles [J].
Evangelisti, Sara ;
Tagliaferri, Carla ;
Brett, Dan J. L. ;
Lettieri, Paola .
JOURNAL OF CLEANER PRODUCTION, 2017, 142 :4339-4355
[12]   Thermal integration of a metal hydride storage unit and a PEM fuel cell stack [J].
Forde, T. ;
Eriksen, J. ;
Pettersen, A. G. ;
Vie, P. J. S. ;
Ulleberg, O. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (16) :6730-6739
[13]   Modeling and operation optimization of a proton exchange membrane fuel cell system for maximum efficiency [J].
Han, In-Su ;
Park, Sang-Kyun ;
Chung, Chang-Bock .
ENERGY CONVERSION AND MANAGEMENT, 2016, 113 :52-65
[14]   AIR FLOW TRAJECTORY AND SURGE AVOIDANCE OF CENTRIFUGAL COMPRESSOR UNDER VARIABLE PRESSURE OPERATION OF AUTOMOTIVE FUEL CELLS [J].
Han, J. ;
Im, S. ;
Yu, S. .
INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2016, 17 (04) :731-738
[15]   An improved dynamic voltage model of PEM fuel cell stack [J].
Hou, Yongping ;
Yang, Zhihua ;
Wan, Gang .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (20) :11154-11160
[16]   Implementation of a heat recovery unit in a proton exchange membrane fuel cell system [J].
Hwang, Jenn Jiang ;
Zou, Meng Lin ;
Chang, Wei Ru ;
Su, Ay ;
Weng, Fang Bo ;
Wu, Wei .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (16) :8644-8653
[17]   Development of a proton exchange membrane fuel cell cogeneration system [J].
Hwang, Jenn Jiang ;
Zou, Meng Lin .
JOURNAL OF POWER SOURCES, 2010, 195 (09) :2579-2585
[18]   Performance analysis and optimization of PEM fuel cell stacks using flow network approach [J].
Karimi, G ;
Baschuk, JJ ;
Li, X .
JOURNAL OF POWER SOURCES, 2005, 147 (1-2) :162-177
[19]   Parametric study on interaction of blower and back pressure control valve for a 80-kW class PEM fuel cell vehicle [J].
Kim, Dong Kyu ;
Min, Hyung Eun ;
Kong, Im Mo ;
Lee, Min Kyu ;
Lee, Chang Ha ;
Kim, Min Soo ;
Song, Han Ho .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (39) :17595-17615
[20]   Customized design for the ejector to recirculate a humidified hydrogen fuel in a submarine PEMFC [J].
Kim, Minjin ;
Sohn, Young-Jun ;
Cho, Chung-Won ;
Lee, Won-Yong ;
Kim, Chang-Soo .
JOURNAL OF POWER SOURCES, 2008, 176 (02) :529-533